AEG FSK75758P User Manual page 12

Hide thumbs Also See for FSK75758P:
Table of Contents

Advertisement

12
www.aeg.com
The higher the content of these minerals,
the harder your water is. Water hardness
is measured in equivalent scales.
The water softener should be adjusted
according to the hardness of the water in
Water hardness
German de‐
grees (°dH)
47 - 50
43 - 46
37 - 42
29 - 36
23 - 28
19 - 22
15 - 18
11 - 14
4 - 10
<4
1) Factory setting.
2) Do not use salt at this level.
Regardless of the type of detergent
used, set the proper water hardness
level to keep the salt refill indicator
active.
Multi-tabs containing salt are
not effective enough to
soften hard water.
Regeneration process
For the correct water softener operation,
the resin of the softener device needs to
be regenerated regularly. This process is
automatic and is the part of the normal
dishwasher operation.
When the prescribed quantity of water
(see values in the table) has been used
since the previous regeneration process,
a new regeneration process will be
initiated between the final rinse and the
programme end.
French de‐
mmol/l
grees (°fH)
84 - 90
8.4 - 9.0
76 - 83
7.6 - 8.3
65 - 75
6.5 - 7.5
51 - 64
5.1 - 6.4
40 - 50
4.0 - 5.0
33 - 39
3.3 - 3.9
26 - 32
2.6 - 3.2
19 - 25
1.9 - 2.5
7 - 18
0.7 - 1.8
<7
your area. Your local water authority can
advise you on the hardness of the water
in your area. It is important to set the
right level of the water softener to assure
good washing results.
Clarke de‐
grees
58 - 63
53 - 57
46 - 52
36 - 45
28 - 35
23 - 27
18 - 22
13 - 17
5 - 12
<0.7
< 5
Water softener lev‐
el
1
2
3
4
5
6
7
8
9
10
In case of the high water softener setting,
it may occur also in the middle of the
Water softener lev‐
el
10
9
8
7
6
1)
5
4
3
2
2)
1
Amount of water
(l)
250
100
62
47
25
17
10
5
3