Fig. 66: Locking The Rotor - ABB XAC24837 Operation Manual

Table of Contents

Advertisement

Operation Manual / A200-L
10 Taking a turbocharger out of operation / 10.2 Taking defective tur-
bochargers out of operation
10.2.2
Procedure with two or more installed turbochargers per
engine
CAUTION
Machine damage due to too high turbocharger speed
The permissible turbocharger speed for the unlocked turbocharger may not
exceed n
cessive speeds. The values provided by the enginebuilder apply to the max-
imum admissible engine load.
Observe the permissible turbocharger speed for the unlocked turbochar-
u
ger.
Reduce the engine load if necessary.
u
Stop the engine.
u
Close off oil supply to defective turbocharger.
u
Blank off the inlets and outlets of the defective turbocharger (see chapter
u
the inlets and outlets
Continue to operate engine in accordance with enginebuilder's instructions. Observe the
u
prescribed power reduction.
10.2.3
Locking the rotor
Fig. 66: Locking the rotor
© Copyright 2021 ABB. All rights reserved.
. Serious damage to engine or property can be caused by ex-
Bmax
→115).
HZTL4036_EN
Blanking off
Rev.T