SAFETY PRECAUTIONS This device is to be serviced only by properly qualified service personnel. Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy. PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...
SPECIFICATIONS ITEM DESCRIPTION MS-1904H MODEL 230 Volts AC 60 Hz Power Requirement 1,000 Watts Single phase, 3 wire grounded Power Output 700 Watts full microwave power (IEC705) 2,450 MHz Microwave Frequency Magnetron 2M218J 0 ~ 99 min. 50 sec. Timer...
CAUTIONS Unlike other appliances, the microwave oven is MICROWAVE RADIATION high-voltage and high-current equipment. Personnel should not be exposed to the Though it is free from danger in ordinary use, microwave energy which may radiate from the extreme care should be taken during repair. magnetron or other microwave generating device if it is improperly used or connection.
INSTALLATIONS BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY. INSTALLING EARTHING INSTRUCTIONS 1. Empty the microwave oven and clean inside it with This microwave oven is designed to be used in a fully a soft, damp cloth. Check for damage such as earthed condition.
OPERATING INSTRUCTIONS FEATURES Oven Front Plate Window Door Screen Door Seal Display Window Control Panel Door Open Button Safety Door Lock System Turntable Rotating Ring CONTROL PANEL 1. DISPLAY WINDOW. 2. AUTO COOK: Used to cook the foods listed by one touch. 3.
OPERATING SEQUENCE The following is a description of component functions 4. AUTO WEIGHT DEFROST COOKING during oven operation. Desired Desired Stop defrost cooking Start 1. MICROWAVE COOKING category weight Desired Desired Stop Start power level cooking time 5. AUTO COOK 2.
CIRCUIT DESCRIPTION • A high voltage of approximately 2100 volts AC is GENERAL DETAILS generated in the secondary of the high voltage • The low voltage transformer supplies the necessary transformer which is increased by the action of the high voltage to the micom controller when power cord is voltage diode and charging of the high voltage plugged in.