BUILD IN APPLIANCES FOR USE WITH LIQUIFIED PETROLEUM (LPG) OR NATURAL GAS CAUTION – ALL OUTER SURFACES WILL GET HOT WHEN IN USE RADIANT GAS FIRE MODELS (LPG) S~FI 20000 S~FI 21000 S~FI 22000 S~FI 23000 MODELS (NATURAL GAS) S~FI 20000NG S~FI 22000NG S~FI 23000NG USER AND INSTALLATION INSTRUCTIONS FOR USE IN: - GB, IE, FR, NL, BE, LU, ES, IT, NO, DE, DK, SE...
Page 7
INTRODUCTION This appliance shall be installed in accordance with the local and national/European standards in force. Particular attention shall be given to the requirements regarding ventilation. Read the instructions before installing or using this appliance. Failure to install the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.
OPERATION Ensure the gas cylinder is turned on. In the event of a gas smell, turn off at the cylinder and contact supplier. IGNITION • Press in the control knob (See Fig. 2 - Control Positions) • Rotate anti-clockwise, until the spark igniter clicks twice. •...
OPERATION The burner on this appliance has fixed aeration and no adjustment is required. Depending on the gas being used, the burners should flame as follows: - Propane - The flames should burn quietly with a blue/green colour with no sign of yellow tips.
INSTALLATION Regulations and Standards In your own interest of safety, it is law that all gas appliances are installed and serviced by competent persons. CORGI (Confederation for the Registration of Gas Installers) registered installers undertake to work to safe and satisfactory standards. Failure to install the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.
Page 11
INSTALLATION POSITION All models must be installed and positioned on a hearth with a minimum distance of 60mm from the outside of the surround trim to the outside of the hearth. The hearth should also extend a minimum of 60mm from the front of the grate. The Solaris LS (Landscape Fire) is also designed to be installed without a hearth in a raised position.
Page 12
INSTALLATION GAS CONNECTION The connection is made to an 8mm OD inlet pipe through the middle of the rear case of the fire. It is recommended that the fire be connected by copper tubing using a compression fitting. Rubber tubing must NOT be used. ELECTRICAL CONNECTION MODEL FI21000 ONLY Fuse Rating –...
INSTALLATION • If smoke is drawn into the outlet then the flue assembly is working correctly, if not then check the following points:- - The flue pipe has been properly sealed. - That there is not a blockage in either the flue pipe or terminal. •...
MAINTENANCE & SERVICING This appliance needs little maintenance other than cleaning. All parts should be cleaned using either a duster or a damp cloth. Do not use abrasive cleaners, steel wool or cleansing powders. The control knob is a push fit and can be removed for cleaning. ALL SERVICING MUST BE CARRIED OUT BY AN APPROVED COMPETENT PERSON AFTER EACH SERVICE THE APPLIANCE MUST BE CHECKED FOR GAS SOUNDNESS IMPORTANT...