GeneralAire GF-3200 DMM Installation And Operating Instructions

GeneralAire GF-3200 DMM Installation And Operating Instructions

With furnace blower motor control

Advertisement

Quick Links

INSTALLATION AND
OPERATING INSTRUCTIONS
About the GFX4 Digital Humidistat
In Automatic Mode the GFX4 will adjust the humidity in your home based on the outdoor temperature, lowering the humidity in cold weather to reduce
condensation. The GFX4 can operate in Manual Mode to control humidity to a speci c relative Humidity. In most homes, Automatic operation is preferred
to reduce condensation on windows and within the structure. Manual mode is necessary where the outdoor temperature sensor cannot be installed.
Manual mode may be desirable where valuable artwork, instruments or woodwork demand constant humidity. The GFX4 has a dry contact for fan control
(FAN1, FAN2 terminals). The LCD Display is backlit and easy to read. Operation and Installation are simple. The GFX4 can be mounted on an interior wall or
on the return duct of the HVAC System.
!
WARNING!
This Humidistat must be installed by a Quali ed Technician. Always TURN OFF POWER TO THE HVAC SYSTEM PRIOR TO INSTALLING OR SERVICING the
Humidi er or Humidistat. Improper operation can result in over or under humidi cation. Over humidi cation can result in condensation, structural damage
or mold. Condensation within a building's structure can cause a loss of structural strength. Condensation can also enable mold and mildew growth resulting
in personal injury and damage to building structure and contents. Older and poorly insulated structures cannot withstand the same humidity levels as
newer well insulated buildings. Read these instructions carefully. This humidistat requires a 24 volt, AC power supply. Improper voltage can cause
malfunction or damage to the control. Do not run outdoor sensor wires on or near line voltage wires. The technical speci cations for this product and the
contents of the user manual are subject to change without notice.
Speci cations
Voltage
20-30 VAC, 60Hz.
Switching Load
1 amp max. 30 volt
Outdoor Sensor
max. 200 ft. 61m.
Auto Mode
Control Range
10%-60% RH.
Outdoor Temp.
-10°F, -23°C min.
Manual Mode
Control Range
10%-75% RH
Accuracy -RH (77°F, 25°C)
20%-80% ±4%RH
Accuracy Drift Per Year
±0.5%RH
Accuracy Indoor Temp.
±2°F, ±1°C
Accuracy Outdoor Temp.
±2°F, ±1°C
Resolution, Temp. or RH 1° or 1%.
Setting - 1%RH
Relay Close
Setting +1%RH
Relay Open
With Furnace
Blower Motor
Control
GFX4 Locations
YES!
YES!
Wall Installation
1" Hole.
Wall base has vents.
If wires are run inside wall,
cut rectangular opening.
Secure the base with the
two plastic anchors and
screws.
®
Outdoor Sensor Location
YES!
YES!
Over Snow Line
Inlet of Air Intake
Less than 200'
from humidistat.
Duct Installation
YES !
NO!
North Wall
South Wall
East Wall
West Wall
Below Snow
Deep in Intake
More than 200'
from humidistat.
1" Hole.
Duct base: no vents.
If wires are run inside duct,
cut rectangular opening.
Secure the base with the
two sheet metal screws.

Advertisement