Venting Requirements - KitchenAid KVWC906KSS Installation Instructions Use And Care Manual

36" and 48" (91.4 cm and 121.9 cm) commercial style wall-mount
Hide thumbs Also See for KVWC906KSS:
Table of Contents

Advertisement

Available languages

Available languages

Back View
A
9 "
5
8
(24.4 cm)
18
" (47.8 cm) for 48" (121.9 cm) Hood
13
16
12
13
" (32.5 cm) for 36" (91.4 cm) Hood
16
A. Knockout into terminal box
B. Top of hood
C. Wood support
D. Bottom of hood
Optional Full-Width Duct Cover Installations
12"
(30.5 cm)
12"
(30.5 cm)
18"
(45.7 cm)
A. Optional full-width duct cover
B. Range hood
Installation Dimensions
36.06" (91.6 cm), or 48.07" (122.1 cm)
(If installed between cabinets)
Bottom of Range hood
18" (45.7 cm) min.
to cooking surface
clearance upper
cabinet to countertop
36" (91.4 cm)
countertop height
IMPORTANT:
Minimum distance "X": 24" (61 cm) from electric cooking
surfaces
Minimum distance "X": 30" (76.2 cm) from gas cooking
surfaces
Suggested maximum distance "X": 36" (91.4 cm)
B
18"
CL
C
(45.7 cm)
D
A
B
cabinet opening width
12" (30.5 cm)
X
13" (33.0 cm )

Venting Requirements

Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide effi cient performance.
For the most effi cient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than one elbow is used.
Do not install two elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the cap has a
damper, do not use the damper supplied with the range
hood.
Use caulking to seal exterior wall or roof opening around
the cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air fl ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specifi ed CFM of
air movement. The specifi ed CFM varies from locale to locale.
Consult your HVAC professional for specifi c requirements in
your area.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
Roof Venting
Wall Venting
A
B
B
A. Roof cap
A. Wall cap
B. 10" (25.4 cm)
B. 10" (25.4 cm)
round vent
round vent
Wall Venting
B
A
A
A. Wall cap
B. 10" (25.4 cm)
round vent
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kvwc906kss0Kvwc908kss0

Table of Contents