LG 86US340C0UD.ACC Easy Setup Manual page 33

Table of Contents

Advertisement

Available languages

Available languages

RS-232C configurations
7-Wire Configurations
(Standard RS-232C cable)
PC
2
RXD
3
TXD
5
GND
DTR
4
6
DSR
7
RTS
8
CTS
D-Sub 9
Set ID
For Set ID number, see "Real data mapping (Hexadecimal: Decimal)".
1 Press
(Settings)
2 Press the Navigation buttons to scroll to ([General] [Set ID]) and press
3 Scroll left or right to select a [Set ID] number. The adjustment range is 1-99.
TV
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
D-Sub 9
(
) to access the main menus.
3-Wire Configurations
(Not standard)
PC
2
RXD
3
TXD
5
GND
DTR
4
6
DSR
7
RTS
8
CTS
D-Sub 9
.
TV
3
TXD
2
RXD
5
GND
6
DSR
4
DTR
8
CTS
7
RTS
D-Sub 9
25

Advertisement

Table of Contents
loading

Table of Contents