A: Battery Separator; B: F1 Fuse 60 Amp (Maxi); C: F2 Fuse 15 Amp (Mini); D: F3 Fuse 20 Amp (Mini) - freightliner Park Smart Technical Information

A fully integrated electrical temperature management unit
Table of Contents

Advertisement

A: Battery Separator

The battery separator is used for separating
the trucks main starting batteries from the
AUX batteries. It also allows the charging
of the AUX batteries after the main truck batteries
are charged above 13.2 Volts. Mounting is outside the
truck on the frame rail.
This device should be protected from the elements
.
due to corrosion and exposure to short circuits

B: F1 Fuse 60 Amp (Maxi)

This fuse provides short circuit
F4
protection for the compressor.
Location: On the control center.
F2 F3 F5

C: F2 Fuse 15 Amp (Mini)

F1
This fuse provides short circuit protection
for the unit controls.
Location: On the control center
100 A
100 A
D: F3 Fuse 20 amp (Mini)-Heater
This fuse provides protection for the
fuel fired heater.
100 A
Location: On the control center
100 A

E: F4 Fuse 50 Amp (Maxi)

This fuse provides protection for the
evaporator blower.
Location: On the control center

F: F5 Fuse 15 Amp (Mini)

This fuse provides protection for the condenser
fan.
Location: On the control center
NEVER INSTALL FUSE F6. THIS IS FOR PROGRAMMING ONLY AND IF
INSTALLED IT WILL DISABLE THE PARKSMART UNIT!