TABLE OF CONTENTS PAGE GENERAL INFORMATION …........ PRODUCT DATA AND SPECIFICATIONS.... UNIT DESCRIPTION Standard Features........Applications / Operation......Electrical Configurations......Use of Extension Cords…………………. Condensate..........Accessories………......... 8 - 14 Inspection/Installation......Deluxe Electronic Controller....16-18 SERVICE Replacement Parts Procedure....Troubleshooting Guide......Preventive Maintenance......
GENERAL INFORMATION The OceanAire 2OAC is a portable air-cooled spot cooler designed for permanent or temporary spot cooling applications. The entire unit has been built in a premium sheet metal cabinet, equipped with heavy-duty casters for mobility. All 2OAC models come standard with a 10-foot power cord for electrical connection and added mobility in service.
STANDARD FEATURES CABINET The 2OAC Series spot cooler has a cabinet that is constructed of 18 gauge steel with a polyester powder coated finish that will compliment any decor. The cool blue front compliments any surrounding space, and is insulated with sound-absorbing insulation for cool, quiet comfort.
APPLICATIONS COOLING MODE—SPOT COOLER The 2OAC can be used in an open environment to cool specific objects or "spots". Spot Cooling is a convenient and economical way to provide air conditioning, where cooling the entire space is impractical. Cool air is discharged from the unit and is directed where it is needed.
ELECTRICAL CONFIGURATION All 2OAC-Series units are equipped with a standard 10-foot long service cord with plug configurations and receptacle requirements as shown in this chart. 2OAC1211, 2OAC1811, 2OAC2412 and 2OAC3612 units come with LCDI (Leakage Current Detection & Interruption) devices that serve as a means of electrical protection. CAUTION DO NOT USE THE LCDI AS AN ON/OFF SWITCH FOR THE UNIT All 3-phase models are equipped with locking plugs for added connection reliability.
USE OF EXTENSION CORDS CAUTION FOR MODEL 2OAC1211 AN EXTENSION CORD CAN BE USED, PROVIDED IT IS RATED AT LEAST 15 AMPS @ 115 VOLTS WITH GROUNDING-TYPE ATTACHMENT PLUG AND GROUNDING TYPE CONNECTOR (LOAD FITTING) FOR MODEL 2OAC1811 AN EXTENSION CORD CAN BE USED, PROVIDED IT IS RATED AT LEAST 20 AMPS @ 115 VOLTS WITH GROUNDING-TYPE ATTACHMENT PLUG AND GROUNDING TYPE CONNECTOR (LOAD FITTING) FOR MODEL 2OAC2412...
CONDENSATE For Models 2OAC1211, 2OAC1811, 2OAC24 and 2OAC36, a 5-gallon polyethylene tank is provided to collect condensate. The tank is located in the lower front section of the unit, and can be accessed though the condensate tank door. When the high water level is reached, a cut-out switch will AUTOMATICALLY cycle off the compressor/condenser fan.
Page 10
2OAC ACCESSORIES NOTE IT IS IMPORTANT TO SPECIFY MODEL NUMBER AND SERIAL NUMBER WHEN ORDERING ACCESSORIES CONDENSER CONDENSER RETURN DISCHARGE CEILING CEILING PANEL PANEL (CK) (CK-PL) NOZZLE KIT DISCHARGE DUCT ADAPTER DUCT FLANGE ROUND FLEX-DUCT (SOLD SEPARATELY) EVAPORATOR CONDENSER RETURN AIR RETURN AIR PLENUM PLENUM...
ACCESSORIES CEILING PANEL DUCT KIT 2 x 2 CEILING DUCT-PANEL A ceiling panel kit is available for discharging the condenser air above a drop ceiling. The ceiling panel duct kits are furnished with a white vinyl VINYL COATED coated flexible duct that allows for convenient FABRIC DUCT installation.
Page 13
ACCESSORIES DISCHARGE AIR NOZZLE KIT ASSEMBLY The optional discharge nozzle kits are used to direct the conditioned air to a specific target area. By concentrating the airflow, the nozzles increase the air velocity towards production lines to cool personnel and/or equipment. In server rooms, the nozzles can be used to direct the airflow through the rack, and remove the hot air from the equipment area.
Page 14
ACCESSORIES CONDENSER RETURN AIR PLENUM Condenser return air plenums are available for installations where it is required to duct air to the inlet of the condenser. The plenum easily fits into place on the back of the unit, and is provided with a flange for connecting 12-inch or 16-inch flexible ducting. A con- denser return air plenum can substantially reduce air noise and allow the unit to operate without drawing condenser air from the conditioned space.
Page 15
ACCESSORIES EVAPORATOR RETURN AIR PLENUM Evaporator return air plenums are available for installations where it is required to duct air to the inlet of the evaporator. The evaporator return air plenums allow the user to connect round duct (flexible or rigid) to the return air intake to reduce air noise and increase the number of options for solving difficult application problems.
Page 16
ACCESSORIES DISCHARGE DUCT ADAPTER Discharge duct adapters are available for applications where ducted evaporator discharge is required. The adapters can be easily installed on the unit without fasteners, and can be used for either vertical or horizontal ducting. The standard discharge grille is removed and the 2DDA is attached in the grille opening.
INSTALLATION INSTRUCTIONS RECEIVING—INSPECTION Upon receiving your 2OAC unit, inspect the packaging for any damage. All units are shipped on a skid, and packaged in a triple-wall carton for added protection. BEFORE INSTALLING Check the unit for any damage. All OceanAire products are thoroughly inspected at the factory and carefully packaged.
DELUXE ELECTRONIC CONTROLLER The 2OAC controller is equipped with many features for a more precise level of cooling and operation. Additionally, the controller can be removed from the unit and installed for remote operation, if needed (accessory parts may be required). POWER button OCEANAIRE DELUXE ELECTRONIC CONTROLLER...
Page 19
FAN SPEED —The operator can select between AUTO or MANUAL fan speed con- trol. Pressing the FAN SPEED button, will switch speed from AUTO to MANUAL. In MANUAL mode, pressing the FAN SPEED button will change fan speed from low to high. In AUTO mode, the fan speed is controlled automatically.
REPLACEMENT PARTS PROCEDURE IT IS RECOMMENDED THAT ALL OCEANAIRE UNITS BE SERVICED BY A LICENSED TECHNICIAN WARNING —TO AVOID INJURY, DISCONNECT UNIT POWER PRIOR TO SERVICING A. FAN MOTORS 1. Remove cabinet's left-side panel (when looking at the front of the unit). 2.
TROUBLESHOOTING GUIDE The following steps and procedures are recommended for correcting the problems indicated. In the event that the problem can not be corrected, service may be required. SERVICE SHOULD BE PERFORMED BY A QUALIFIED AIR CONDITIONING SERVICE TECHNICIAN PROBLEM: UNIT DOES NOT POWER UP CAUSE: Power interruption REMEDY: Check LCDI (on models with LCDI), and reset LCDI.
PREVENTIVE MAINTENANCE 2OAC Spot Coolers are designed to last a long time and to give maximum performance and reliability with minimum maintenance. To prolong the life of the unit, regular maintenance must be performed as specified below: BLOWER MOTORS The motors on all units have permanently lubricated bearings. No oiling is necessary FILTERS A clogged filter will cause the unit to operate at greatly reduced efficiencies.
WIRING SCHEMATIC FOR 2OAC1211, 1811 and 2412 CONDENSATE DISCHARGE TANK FULL TEMP SENSOR SWITCH CEAN IRE POWER MODULE OPTIONAL CONDENSATE PUMP 2DPC-1 (115V) OR 2DPC-2 (208-230V) INSTALL SAFETY SWITCH IN LOW-VOLTAGE LOOP REPLACING TANK FULL SWITCH AIR-COOLED SPOT COOLER MODELS 2OAC1211, 2OAC1811 115 V / SINGLE-PHASE MODELS 2OAC2412 208-230 V / SINGLE-PHASE...
Page 27
WIRING SCHEMATIC FOR 2OAC3612 DISCHARGE CONDENSATE TEMP TANK FULL SENSOR SWITCH CEAN IRE POWER MODULE Plug 6-30P OPTIONAL CONDENSATE PUMP KIT 2DPC-2 (208-230V) INSTALL SAFETY SWITCH IN LOW-VOLTAGE LOOP REPLACING CONDENSATE TANK FULL AIR-COOLED SPOT COOLER MODELS 2OAC3612 208-230 V/ SINGLE-PHASE...
THREE PHASE MONITOR Three-Phase units are equipped with monitors for motor protetion. The OceanAire Three-phase Monitor safeguards the unit against incorrect compressor rotation, low-voltage and/or loss of power in any one of the power legs. The monitor is installed in the control box and is equipped with an LED for diagnosis of an improper electrical condition (see diagrams below).
LIMITED WARRANTY The Manufacturer (OceanAire, Inc.) warrants to the original owner that the Product will be free from defects in material or workmanship for a period not to exceed one (1) year from date of installation. If upon examination by the Manufacturer, the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective.
Page 36
END USER INFORMATION MODEL: ______________________________________ SERIAL NUMBER: _____________________________ Date Purchased: ______________________________ Purchased from: _______________________________ Date Installed: _________________________________ For Technical Support or service parts, contact our Keep Cool Team at 847-583-0311 In order to receive the benefits of our warranty, please register on-line at www.oceanaire-inc.com Form EISM-2OAC 01012019...