Woodbridge GLO-18 Owner's Operation And Installation Manual

Woodbridge GLO-18 Owner's Operation And Installation Manual

18" and 24" outdoor gas log set

Advertisement

Quick Links

We recommend that our products be installed
and serviced by professionals who are certified
in the U.S. by NFI (National Fireplace Institute).
ANSI Z21.97-2014/CSA 2.41-2014 "Outdoor Decorative Gas Appliances"
CARBON MONOXIDE HAZARD
DANGER
This appliance can produce
carbon
has no odor.
enclosed space can kill you.
Never use this
in an enclosed space as a
camper, tent, car or home .
DANGER
If you smell gas:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the
appliance and immediately call your
gas supplier or fire department.
WARNING:
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Version française de ce manuel est disponible à partir du site WEB : www.woodbridgefp.com
F rench version of this Owners Manual is available at www.woodbridgefp.com
Woodbridge Fireplace Inc.
OW NER' S O PER AT ION AND IN ST ALL AT ION MANU AL
1 8" and 24" OUTDOOR GAS LOG SET
GLO-18(N,P), GLO-24-(N,P)
NATURAL GAS / PROPANE
C GA 2.17-M91(R2014) "Gas Fired Appliances for Use at High Altitudes"
monoxide
Using it in an
appliance
For Outdoor Use Only
Complies with
WARNING
which
Improper installation, adjustment, alteration, service,
or maintenance can cause injury or property damage.
Read the installation, operating and maintenance
instructions thoroughly before installing or servicing
this equipment.
WARNING
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
An LP-cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
R eport # 0401GM017S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GLO-18 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Woodbridge GLO-18

  • Page 1 Woodbridge Fireplace Inc. OW NER’ S O PER AT ION AND IN ST ALL AT ION MANU AL 1 8" and 24" OUTDOOR GAS LOG SET GLO-18(N,P), GLO-24-(N,P) NATURAL GAS / PROPANE We recommend that our products be installed and serviced by professionals who are certified in the U.S.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety Information ..........3 Local Codes ............4 Specifications............5 Locating Your Fireplace ........6 Gas Connection ..........7 Burner Assembly Instructions ......8 18" Log Set Installation ........10 24" Log Set Installation ........11 Lighting Instructions ...........
  • Page 3: Safety Information

    SAFETY INFORMATION WARNINGS 6 . Do not allow fans to blow WARNING: Any change directly into the fireplace. to this Gas Log Set or its WARNING: Keep flue Avoid any drafts that alter open when operating unit. controls can be dangerous. burner flame patterns, as it could increase soothing.
  • Page 4: Local Codes

    SAFETY INFORMATION 15 . Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a profesional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments,burners and circulating air passageway of the appliance be kept clean.
  • Page 5: Specifications

    (with logs installed) Width Depth Height Model Width Depth Height Front Rear 23" 14" 17” " 30 " 23" GLO-18 16 " 29" 15" 18” 16 " " 36" 24" GLO-24 G L O -18 Specifications Parameter / Model G L O -18 N...
  • Page 6: Locating Your Fireplace

    LOCATING YOUR FIREPLACE IMPORTANT This outdoor gas log set is designed to be placed and operated inside a custom built NON-COMBUSTIBLE FIREBOX. See previous page for the firebox specifications. If you are planing to locate your firebox inside of any outdoor structure (enclosure), please refer to the following. LOCATING YOUR OUTDOOR GAS FIREPLACE.
  • Page 7: Gas Connection

    GAS CONNECTION CHECK GAS TYPE Use proper gas type for the Log Set you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the Log Set for proper fireplace for your gas type or conversion kit. INSTALLING GAS PIPING TO FIREPLACE / BURNER SYSTEM LOCATION WARNING A qualified installer or service person must...
  • Page 8 GAS CONNECTION Test Pressures in Excess Of CONNECTING TO GAS traps moisture and contaminants. 1/2 psi (3.5 kPa) This keeps them from going into SUPPLY Outdoor Log Set controls. The appliance and its individual If sediment trap is not installed or WARNING: A qualified shutoff valve must be discon-...
  • Page 9: Burner Assembly Instructions

    BURNER ASSEMBLY INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to only parts specially approved with this appliance result property damage or personal injury. 1 . Carefully remove all parts from the box and inspect them for any damage. Read the Certification Tag attached. DO NOT REMOVE ANY LOG S FROM ORIGINAL PACKAGING TILL STEP # 7 AS BREAKAGE MAY EASILY OCCUR.
  • Page 10: 18" Log Set Installation

    18" LOG SET INSTALLATION GLO-18 LOG SET LOG PLACEMENT...
  • Page 11: 24" Log Set Installation

    24" LOG SET INSTALLATION GLO-24 LOG SET LOG PLACEMENT...
  • Page 12: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This apliance is equiped with a pilot which must be lit by hand while following these instructions exactly. B.
  • Page 13 LIGHTING INSTRUCTIONS LIGHTING PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD You may check for gas leaks with the following methods only: WARNING • Soap and water solution WARNING • An approved leak testing spray If using a soap and water solution to test •...
  • Page 14: Operating Instructions

    LIGHTING INSTRUCTIONS LIGHTING BURNER MAIN BURNER SWITCH / REMOTE The “ON/REMOTE/OFF” switch for the main burner can be found on remote control receiver be neath the base. This switch allo ws you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 15: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
  • Page 16: Troubleshooting

    TROUBLESHOOTING WARNING:Turn off appliance WARNING: If you smell gas • Shut off gas supply. and let cool before servicing. Only • Do not try to light any appliance. a qualified service person should • Do not touch any electrical switch; do not use any phone in service and repair this appliance.
  • Page 17 TROUBLESHOOTING POSSIBLE CAUSE OBSERVED PROBLEM REMEDY 1. Unit burning vapors from paint, hair Gas Log Set produces unwanted odors 1. Open flue to maximum. Stop using odor causing products while unit is running spray, glues, cleaners, chemicals, new carpet, etc. 2.
  • Page 18: Illustrated Parts Breakdow N , Parts List

    ILLUSTRATED PARTS LIST FOR PART DESCRIPTION SE E NE XT PAGE...
  • Page 19 ILLUSTRATED PARTS LIST This list contains replaceable parts used in your outdoor fire place . All replacement parts should be ordered from your installer or from Woodbridge Fireplace Inc. at 1-905- 564 - 3001 or on-line at www.woodbridgefp.com GLO-18" LOG SET PART NUMBER QT.
  • Page 20 Woodbridge Fireplace Inc. in the appliance are found to be defective in materials or workmanship, Woodbridge Fireplace Inc. will, at its option, replace or repair the defective components at no charge to the original owner. Woodbridge Fireplace Inc. will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation.

This manual is also suitable for: