ebm-papst A2E250-AD05-05 Operating Instructions Manual

ebm-papst A2E250-AD05-05 Operating Instructions Manual

Advertisement

Quick Links

A2E250-AD05-05
SEW-USOCOME SA
CONTENTS
Item no. 10316-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 1 / 10
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
E-mail: zakaz@ventilatorry.ru

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A2E250-AD05-05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst A2E250-AD05-05

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA CAUTION → Do not wear any loose-fitting or dangling clothing or jewelry Electric charge on capacitor after device is switched off while working on rotating parts. Electric shock, risk of injury → Protect long hair with a cap.
  • Page 3: Intended Use

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Cable PFA, 4x crimped splices Direction of air flow "V" Max. clearance for screw 5 mm Item no. 10316-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 4 / 10...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M2E068-CA cycles. If you have special questions, consult ebm-papst for support. Phase ; Use the device in accordance with its degree of protection.
  • Page 6: Connection And Startup

    Bearing damage, shorter service life ; If the motor run capacitor was not installed by ebm-papst, check → The fan must not be subjected to force or excessive vibration whether the information on the motor run capacitor matches the from sections of the installation.
  • Page 7: Connecting The Cables

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA 4.3 Connecting the cables The device has external leads. ; First connect the "PE" (protective earth). Connect the cables according to your application. When doing so, ● observe Chapter 4.4 Connection diagram. 4.3.1 Cable routing Water must be prevented from reaching the cable exit along the cable.
  • Page 8: Connection Diagram

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA 4.4 Connection diagram blue brown black green/yellow Item no. 10316-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 8 / 10 E-mail: zakaz@ventilatorry.ru...
  • Page 9: Checking Connections

    Operating instructions A2E250-AD05-05 SEW-USOCOME SA 4.5 Checking connections 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible Do not perform any repairs on your device. Send the device to ebm- ;...
  • Page 10: Cleaning

    Right from the development stage, ecological design, technical safety electronic scrap. and health protection are fixed criteria. → Please contact ebm-papst for any other questions on disposal. The following section contains recommendations for ecological disposal of the product and its components.