Nivetec EchoTREK ST-400 Series Installation And Programming Manual

Four-wire compact ultrasonic level transmitters

Advertisement

Quick Links

EchoTREK
ST/SB-400 series four-wire
compact ultrasonic level transmitters
Installation and Programming Manual
nd
2 edition
sba4802a0600p_02 ♦ 60/1

Advertisement

Table of Contents
loading

Summary of Contents for Nivetec EchoTREK ST-400 Series

  • Page 1 EchoTREK ST/SB-400 series four-wire compact ultrasonic level transmitters Installation and Programming Manual 2 edition sba4802a0600p_02 ♦ 60/1...
  • Page 2 BASIC CONCEPTS AND ELEMENTS OF THE ULTRASONIC MEASUREMENT Close end blocking (programmed value DIST= distance (measured) Programmed measurement range of the application LEV= level calculated; H - DIST) VOL= volume (calculated from DIST LEV) Far end blocking 60/2 ♦ sba4802a0600p_02...
  • Page 3: Table Of Contents

    CONTENTS 1. INTRODUCTION..................5 6. PARAMETERS – DESCRIPTIONS AND PROGRAMMING....27 6.1 M ............27 EASUREMENT ONFIGURATION 2. ORDER CODES..................6 6.2 C ................33 URRENT UTPUT 6.3 R ................34 ELAY UTPUT 3. TECHNICAL DATA................7 6.4 M ............35 EASUREMENT PTIMISATION 6.5 D ..................39 ATA LOGGER 3.1 A ..................11 CCESSORIES...
  • Page 4 60/4 ♦ sba4802a0600p_02...
  • Page 5: Introduction

    Thank you for choosing a NIVELCO instrument. We are sure that you will be satisfied throughout its use. 1. INTRODUCTION Application A Total beam angle of 5°-7° at –3 dB as is featured by most of Nivelco’s SenSonic transducers ensuring a reliable measurement in narrow silos with The EchoTREK compact ultrasonic level transmitters from NIVELCO are an uneven side walls as well as in process tanks with various protruding objects.
  • Page 6: Order Codes

    2. ORDER CODES Note: not all combinations are possible EchoTREK S RANSDUCER EASURING OUNTING UTPUT OUSING ANGE Transmitter PP/Aluminium 25 m BSP thread 4…20 mA + R1+R2 / 230V AC PVDF/Aluminium 12; 15 m NPT thread 4…20 mA + R1+R2 / 24V AC / DC Transmitter with local indicator PTFE/Aluminium...
  • Page 7: Technical Data

    3. TECHNICAL DATA ENERAL DATA Transducer materials Polypropylene (PP) Kynar (PVDF) Teflon (PTFE) Stainless Steel (DIN 1.4571, AISI SS316Ti) ® Housing material Plastic: Glass fibre plastic PBT (DuPont ) Aluminium: Powder paint coated PP,PVDF and PTFE transducers: –30 °C ... +90 °C Process temperature Stainless Steel transducer : -30°…...
  • Page 8 EchoTREK PVDF PECIAL DATA OF THE FOUR WIRE WITH TRANSDUCERS ST -49 - ST -48 - ST -47 - ST -46 - ST -44 - ST -42 - SB -49 - SB -48 - SB -47 - SB -46 - SB -44 - SB -42 - Transducer material...
  • Page 9 Dimensions of the four-wire EchoTREK EchoTREK S -49 - / PP, PVDF, PTFE EchoTREK S -48 - / PP, PVDF, PTFE EchoTREK S -47 - / PP, PVDF, PTFE 2xM20x1,5 2xM20x1,5 2xM20x1.5 2xNPT1/2” 2xNPT1/2” 2x N PT1/2" BSP, 15mm BSP, 15 mm BSP, 15mm NPT, 22mm NPT, 22 mm...
  • Page 10 EchoTREK S S-46 - / SS316 Ti EchoTREK S S-44 - / SS316 Ti 2xM20x1,5 2xM20x1,5 2xNPT1/2” 2xNPT11/2” Ø170 DIN DN80 PN10 DIN DN125 PN10 ANSI 3” 150 psi ANSI 5” 150 psi Ø133 Ø185 Ø200 Ø250 EchoTREK S S-42 - / SS316 Ti 2xM20x1,5 2xNPT1/2”...
  • Page 11: Accessories

    3.1 A CCESSORIES − Certificate of Warranty — 2 x M20x1.5 cable gland − Installation and Programming Manual — SAP-200 Display Module (option) − Declaration of Conformity — CD-ROM (EViewLight, DataScope softwares) (option) 3.2 M AINTENANCE AND REPAIR The EchoTREK B/ST series do not require maintenance on a regular basis. In some very rare instances, however, the transducer may need a cleaning from deposited material.
  • Page 12: Installation

    4. INSTALLATION 4.1 L IQUID EVEL EASUREMENT POSITION The optimal position of the EchoTREK is on the radius r = (0.3 … 0.5) R of the (cylindrical) tank / silo. (Take also sonic cone on page 1 into consideration.) SENSOR ALIGNMENT TEMPERATURE The sensor face has to be parallel to Make sure that the transmitter will...
  • Page 13 OBSTACLES STAND-OFF PIPE Make sure that no in-flow path or objects The structure of the stand off pipe should be rigid; the inner rim where the ultrasonic (e.g. cooling pipes, ladders, bracing beam leaves the pipe should be rounded. members, thermometers, etc.) or no tank wall of the ragged surface protrude into D min the sensing cone of the ultrasonic beam.
  • Page 14: Open Channel Flow Measurement

    4.2 O HANNEL EASUREMENT • For ultimate accuracy, install the sensor as close as possible above the expected maximum water level (see minimum measuring range). • Install the device in a place defined by the characteristics of the metering channel along the longitudinal axis of the flume or weir. In case of Parshall flumes supplied by NIVELCO the location of the sensor is marked.
  • Page 15: Programming

    Transmitter Display Module Connector 230 V AC Power Supply C OM NO Rel a y1 Power Supply Unit Indicator 4 ... 20 mA Power supply e.g. e.g. PPK-331 PDF-401-2 Current Output + I - (HART)* 24 V DC Rel a y2 1/2"NPT 1/2"NPT 4...20 mA...
  • Page 16 Devices with the type number EchoTREK SG... are already equipped with the SAP-200. The EchoTREK is fully operational without the SAP-200. The SAP-200 is only needed for programming and/or displaying measurement values. The unit will measure during programming in accordance with the previous parameters. The new, modified parameters will only be effective after returning to the Measurement Mode If the transmitter is left in Programming Mode by mistake, it will automatically return to Measurement Mode after 30 minutes and will operate with the parameters entered during the last completed programming.
  • Page 17: Rogramming Without

    5.1 P ROGRAMMING WITHOUT ISPLAY ODULE Programming is only possible if the EchoTREK is in Level Measuring Mode and receives valid echo i.e. “VALID” LED is lit! The following can be programmed without display module • Assignment of the 4 mA to a required e.g. min. level / max. distance •...
  • Page 18 Maximum level (100%, full tank) assignment to 20 mA Action Led state following the action 1) Check for a valid ECHO Valid ECHO, transmitter programmable 2) Press NEXT button steadily EchoTREK in programming mode 20 mA as signed to the distance 3) Press DOWN button steadily (see picture)
  • Page 19 Damping time setting (Check for a valid echo as above) Action Led state following the action 1) Press ENTER button steadily EchoTREK in programming mode 2) Press any of the NEXT – 10 sec – 30 sec DOWN – 60 sec buttons steadily 3) Release buttons Programming completed...
  • Page 20 5.2 P SAP-200 D ROGRAMMING WITH THE ISPLAY ODULE The EchoTREK should be adjusted to the process by programming the parameters. The SAP-200 Display Module can be used to display the parameters during programming and measurement values during measurement. The SAP-200 supports two separately accessible programming modes representing 2-layers of programming complexity, depending on user choice. PLUG-IN DISPLAY MODULE FULL QUICKSET...
  • Page 21: Sap-200 Display Module

    5.2.1 SAP-200 Display Module Symbols used on the LCD: Symbols used on the frame: • DIST – Distance (measuring) mode • M – Metric system • LEV – Level (measuring) mode • US – US calculation system • VOL – Volume (measuring) mode •...
  • Page 22: Indications Of The Sap-200 And Led Status

    Enter into or quit programming modes Basic steps while parameter address is blinking Basic steps while parameter value is blinking Return to default* Display default value * cancellation immediately active * LOAD readout ** CANCEL readout GET LEVEL function Special function used only in level and distance measurement modes + DOWN Notes: If after pressing ENTER...
  • Page 23: Quickset

    SAP-200 indications The following process values can be displayed Depending on the measurement one of the below symbols will lit and the process value • Volume / Flow – if programmed so (Vol/Flow) displayed (see P01 chapter 6.1). Engineering • Level –...
  • Page 24 Keys Function + DOWN (press for min 3 secs!) Enter or exit QUICKSET programming mode ENTER , DOWN , NEXT Increase/decrease and move left the blinking digit + DOWN “GET LEVEL" - display actual level measured by the EchoTREK Save readout and step to the next screen ENTER NEXT + UP...
  • Page 25: Full Parameter Access

    Screens Actions 20 mA xxxx – level value assigned to 20 mA current output Manual: set level value (Use UP / DOWN / NEXT keys) and save it (by ENTER 20:xxxx Automatic: use the “GET LEVEL” function (UP + DOWN ) to obtain actual measured value with level in tank or a fixed target, i.e.
  • Page 26 Measuring is going on during programming in accordance with the old parameter set. New parameter set will be valid after returning to the Measurement to the Programming Mode. Steps and indications of the Full Parameter Access programming mode pressing Keys while Parameter Address is blinking while Parameter Value is blinking Save the modification of the Parameter Value and return...
  • Page 27: Parameters - Descriptions And Programming

    6. PARAMETERS – DESCRIPTIONS AND PROGRAMMING 6.1 M EASUREMENT ONFIGURATION P00: - cba Application/Engineering Units Programming of this parameter will result in loading the factory default with the corresponding engineering units. Operating (measurement) mode Liquid level measurement Engineering units (according to “c”) Attention: mind the sequence! When programming this parameter the Metric...
  • Page 28 P01: - ba Measurement Mode – Bargraph Parameter value „a” will determine the basic measurement value that will be displayed and proportional with the current output. Depending on the value of “a” process values as listed in the 3d column can also be displayed by pressing NEXT .
  • Page 29 P03: - - - a Values displayed - Rounding It is important to keep in mind that the instrument is measuring distance as basic quantity. Measured Distance Resolution The resolution depending on the distance can be considered as a kind of rounding that will be contained in all further value (of level, volume or volume –...
  • Page 30 Maximum Distance to be Measured (H) The maximum distance to be measured is the greatest distance between the surface of the transducer and the level to be measured. This is the only parameter that has to be programmed for each application other than distance (however to avoid disturbing effect of possible multiple echos it is suggested to do this in distance measurement applications too).
  • Page 31 P05: Minimum measuring distance (Dead zone- Close-end blocking) The EchoTREK will not accept any echo within the blocking distance set here. Automatic Close-end-blocking (Automatic Dead Band control) By using the factory default value, the unit will automatically set the smallest possible close-end-blocking distance i.e. the dead band. Manual close-end-blocking Manual close-end-blocking should be used for example to block out the echo originating from the bottom rim of a stand-off pipe or from any object protruding into the ultrasonic cone near to the transmitter.
  • Page 32 P06: Far end blocking Far end blocking is used to neglect incorrect level/volume readings and output actions below a pre-set level programmed in P06. A). Level measurement The far-end blocking can be used to avoid disturbing effect of stirrer or heaters at the bottom of the tanks. If the level of the medium sinks below the blocked out range: "SUB 0"...
  • Page 33: Current Output

    6.2 C URRENT UTPUT P10: Value (of distance, level, volume or flow) assigned to 4 mA current output P11: Value (of distance, level, volume or flow) assigned to 20 mA current output Values are interpreted according to P01(a). Please note that in case of programming for (LEV or VOL) % measurement the min and max value has to be entered in the relevant engineering units of LEV (m, ft) or VOL (m , ft Assignment can be made so that the proportion between the change of the (measured or calculated) process value and the change of the current...
  • Page 34: Relay Output

    6.3 R ELAY UTPUT P13: - - - a Relay function Relay function Also set DIFFERENTIAL LEVEL CONTROL P14, P15 (Hysteresis control) There is a need to set (in level Relay is energised if the measured or min 20mm) hysteresis between calculated value exceeds the value set in P14 P14 and P15 Relay is de-energised if the measured or...
  • Page 35: Measurement Optimisation

    6.4 M EASUREMENT PTIMISATION P20: - - - a Damping This parameter can be used to reduce unwanted fluctuation of the display and output. Damping LIQUIDS time None/moderate Heavy/dense fume or (seconds) fume or waves turbulent waves no filter applicable not recommended recommended applicable...
  • Page 36 P25: - - - a Selection of Echo within the measuring window A so-called measuring window is formed around the echo signal. The position of this measuring window determines the flight time for calculation of the distance to the target. (the picture below can be seen on the test oscilloscope) Received Echo 1.
  • Page 37 P28: - - - a Echo loss indication Echo loss indication Remark During echo-loss, display and analogue output will hold last value. If the echo-loss prevails for 10 sec plus the time period set in P20 (damping time), the reading on the display will change to "no Echo"...
  • Page 38 P29: Blocking out of disturbing object One fixed object in the tank, disturbing the measurement, can be blocked out. Enter distance of the object from the transducer. Use the Echo Map (P70) to read out the precise distance of disturbing objects. FACTORY DEFAULT: 0 P31: Sound velocity at 20°C (m/sec or ft/sec depending on P00(c) )
  • Page 39: Data Logger

    6.5 D ATA LOGGER The logger of the device can store 12288 events. The registry is in a non-volatile (FLASH) memory, so the registry will retain its contents even in case of a power failure. The on-board clock of the device is protected against short power-outs, and keeps working for at least 15 days after the device is switched off.
  • Page 40 P34: - cba Logging mode Operating mode Parameters to be programmed No logging Linear logging P35 – interval (minute) Event-controlled logging when the primary value changes P35 – absolute value of variation Event-controlled logging when primary value changes P35 – variation in % Event-controlled logging when the primary value gets out P35, P36 –...
  • Page 41 P35-36: Log value 1 and log value 2 P34a Operating mode Function of P35 and P36 No logging Linear logging P35 = 0 One entry after every measurement cycle. P35 <> 0 Logging interval (minutes) Value is indifferent Event-controlled logging when the Absolute value of the change in the primary measured value primary value changes (according to P01a)
  • Page 42: Reading Data Out From The Logger

    P37: yyyy Real-time clock, year Year setting for date of the on-board clock. (e.g.: 2005) P38: mmdd Real-time clock, month and day Month (mm) and day (dd) setting for date of the on-board clock. P39: HHMM Real-time hour and minute Hour (HH) and minute (MM) setting of the on-board clock.
  • Page 43: Volume Measurement

    6.6 V OLUME EASUREMENT P40: - - ba Tank shape Tank shape Also to be set Standing cylindrical tank shape (value of “b” as below) P40 (b), P41 Attention! Standing cylindrical tank with conical bottom P41, P43, P44 The value „a” determining the shape of the tank should be Standing rectangular tank (with chute) P41, P42, (P43, P44, P45)
  • Page 44: Volume Flow Measuring

    6.7 V OLUME EASURING P40: - - ba Devices, formula, data Devices, formula, data Also to be set Type Calculation formula Qmin [l/s] Qmax [l/s] “P” [cm] GPA-1P1 Q[l/s]= 60.87*h 0.26 5.38 1.552 GPA-1P2 Q[l/s]= 119.7*h 1.553 0.52 13.3 GPA-1P3 Q[l/s]= 178.4*h 1.555 0.78...
  • Page 45 P41-45: Flume/weir dimensions FACTORY DEFAULT: P40= 00 Nivelco Parshall flumes (GPA1P1 … GPA-1P9) For further details see the Manual of the Parshall flume EchoTREK EchoTREK P40= 09 General Parshall flume 0.305 < P42(width) <2.44 ⋅ ⋅ ⋅ 2.5 < P42 EchoTREK /s]= K*P42*h P42[m]...
  • Page 46 P40= 10 Palmer-Bowlus (D/2) flume /s]= f(h1/P41)*P41 where h1[m]= h+(P41/10) D/10 P40= 11 Palmer-Bowlus (D/3) flume /s]= f(h1/P41)*P41 where h1[m]= h+(P41/10) D/10 P40= 12 Palmer-Bowlus (Rectangular) flume /s]= C*P42*h where C= f(P41/P42) D/10 60/46 ♦ sba4802a0600p_02...
  • Page 47 P40= 13 15cm Khafagi Venturi flume /s]= P42*1.744*h + 0.091*h EchoTREK EchoTREK P40= 14 P40=14 Bottom step weir 0.0005 < Q[m /s] < 1 0.3 < P42[m] < 15 0.1 < h[m] < 10 /s]= 5.073*P42*h Accuracy: ±10% P40= 15 P40=15 Suppressed rectangular or BAZIN weir 0.001 <...
  • Page 48 P40= 16 P40=16 Trapezoidal weir 0.0032 < Q[m3/s] < 82 20 < P41[°] < 100 0.5 < P42[m] < 15 0.1 < h[m] < 2 Q[m3/s]= 1.772*P42*h1.5+1.320*tg(P41/2)*h2.47 Accuracy: ±5% P40= 17 P40=17 Special Trapezoidal (4:1) weir 0.0018 < Q[m3/s] < 50 0.3 <...
  • Page 49 P40= 19 P40=19 THOMSON (90°-notch) weir 0.0002 < Q[m3/s] < 1 0.05 < h[m] < 1 Q[m3/s]= 1.320*h2.47 Accuracy: ±3% P40= 20 P40=20 Circular weir 0.0003 < Q[m /s] < 25 0.02 < h[m] < 2 /s]= m*b*D m= 0.555+0.418h/P41+(P41/(0.11*h)) Accuracy: ±...
  • Page 50: 32-Point Linearisation

    6.8 32-P OINT INEARISATION P47: - - - a Linearisation Linearisation is the method of assigning requested (calibrated or calculated) level, volume or flow to values measured by the transmitter. It can be used for instance if the sound velocity is not known (LEVEL⇒LEVEL) or in the case of tank with other shape than under 6.4 or open channel other than under 6.5 (LEVEL ⇒...
  • Page 51: Informational Parameters

    Conditions of correct programming of the data pairs Left column “L” Right column “r” L(1)= 0 r(1) L(i) r(i) L(j) r(j) The table must always start with: L(1)= 0 and r(1)= value (assigned to 0 level) The table must be ended either with the 32 data pair i.e.
  • Page 52 P70: Number of Echoes / Echo Map Number of echos EchoTREK is monitoring the echo yy : xxxx yy : xxxx 70 : _ _ XX conditions. (DISTANCE) (AMPLITUDE) Entering this parameter will save the actual echo map. yy Serial number of the echo Number, distance and amplitude of these echoes can be read-out one by one.
  • Page 53: Additional

    6.10 A DDITIONAL ARAMETERS OF THE ETERING P76: Head of flow (LEV) The Headwater value can be checked here. This is the “h” value in the formula for flow calculation. P77: TOT1 volume flow totaliser (resetable) P78: TOT2 volume flow totaliser (non-resetable) Resetting TOT1 totaliser: 1).
  • Page 54: Test Parameters

    6.12 T ARAMETERS P80: Current output test (mA) Going to this parameter, the actual current output (corresponding to the measured process value) will be displayed. By pressing ENTER (now blinking) current value can be set for any value between 3,9 and 20.5 mA. The current output has to show the same value which can be checked by an ampere meter, according to the description under 4.4.
  • Page 55: Simulation

    6.13 S IMULATION This function enables the user to test the settings of the outputs. The EchoTREK can simulate the static or continuous change of level according to the simulation cycle time, high level and low level set in P85, P86 and P87. (The simulation levels must be within the programmed measuring range set in P04 and P05.) After selecting simulation type in P85 and setting simulation values Measurement Mode has to be re-entered.
  • Page 56: Error Codes

    7. ERROR CODES Error Error description Causes and solutions Code Memory error Contact local agent No echo received (no reflection) No Echo Echo loss See Action 5 and 6 Hardware error Contact local agent Display overflow Check settings Sensor error or improper installation/mounting, level in Verify sensor for correct operation and check for correct mounting the dead band according to the User’s Manual...
  • Page 57: Parameter Table

    8. PARAMETER TABLE Par. Page Description Value Par. Page Description Value d c b a d c b a Application/Engineering Units Echo loss indication Measurement Mode Blocking out of disturbing object Calculation units N.A. Rounding Sound velocity in different gases Maximum Measuring Distance Specific gravity Minimum Measuring Distance...
  • Page 58 Par. Page Description Value Par. Page Description Value N.A. TOT2 volume flow totaliser N.A. N.A. N.A. Current generator test N.A. Relay test Overall operating hours of the unit N.A. Time elapsed after last switch-on N.A. Operating hours of the relay Simulation mode Number of switching cycles of the relay Simulation cycle time...
  • Page 59: Sound Velocities In Different Gases

    9. SOUND VELOCITIES IN DIFFERENT GASES The following table contains the sound velocity of various gases measured at. Gases Sound Velocity (m/s) Gases Sound Velocity (m/s) Acetaldehyde 252.8 Ethylene 329.4 Acetylene 340.8 Helium 994.5 Ammonia 429.9 Hydrogen sulphide 321.1 Argon 319.1 Methane 445.5...
  • Page 60 sba4802a0600p_02.doc April, 2009 60/60 ♦ sba4802a0600p_02...