Love CR10 Operation Manual

Temperature, humidity & dew point recorder

Advertisement

Quick Links

Bulletin E-90-CR10
LOVE CONTROLS Division of Dwyer Instruments, Inc.
Michigan City, IN U.S.A. 46360
OPERATION MANUAL
CR10
Temperature, Humidity & Dew
Point Recorder

Advertisement

Table of Contents
loading

Summary of Contents for Love CR10

  • Page 1 Bulletin E-90-CR10 LOVE CONTROLS Division of Dwyer Instruments, Inc. Michigan City, IN U.S.A. 46360 OPERATION MANUAL CR10 Temperature, Humidity & Dew Point Recorder...
  • Page 2: Quick Start

    Pens and a chart have already been installed for your conve- reading. nience. All you need to do to start using your CR10 recorder with the settings listed above is follow these quick start instructions: After you get started using the “Quick Start Instruction”, we rec- ommend that you also read the rest of the manual to ensure that 1.
  • Page 3 Instrument Anatomy...
  • Page 4: Operating Information

    The 120V AC adapter plugs into the back of the Probe recorder beneath the probe cradle. The CR10 probe sits in the cradle in the back of the unit. The CR10 probe comes with the standard 8˝ cord. An extension cord can be Display Symbols Reading update indicator.
  • Page 5: Keypad Operations

    Keypad Operations Alarm On/Off Alarm On/Off This button turns the alarms on and off. When alarms are “on”, the alarm symbol appears on the display. When alarm sounds it will sound audibly for approximately 1 minute and then it will stop. For a visual alarm, the variable that has moved outside of the minimum or maximum points that you set will flash.
  • Page 6: Dip Switch Setup

    °F/°C Keypad Lock You can record in °F or °C with the CR10 by using dip switch #3. For security purposes it is possible to lock the keypad to prevent unauthorized persons from using the keypad to set alarms or °F...
  • Page 7: Pen Installation

    4. To raise temperature reading, press the “Alarm Set” key. To 4. Match the CR10 reading with either 11% or 75%, depending lower the temperature reading press the “Alarm On/Off” key. on the salt capsule being used. To raise the RH/Dew Point Each key press adjusts the reading by 1°F.
  • Page 8: Replacement Parts

    Replacement Parts Description Quantity Part# Charts -20° - +120°F/24-hour CR721 -20° - +120°F/7-day (included) CR771 -20° - +50°C/0 - 100% RH/24-hour 100` CR725 0° - +100°F/7-day CR776 +40° - +110°F/0 - 100% RH/24-hour CR724 Note: If you will be using the 14 day recording time, you can use a 7 day chart in the range desired and divide up each day by two. Accessories Replacement Pen Pack 6/pack (3 red, 3 blue)
  • Page 9: Warranty

    4. The problem you’re experiencing with unit. Warranty Dwyer Instruments, Inc. warrants the CR10 will be free from defects in material and workmanship for a period of twelve months The foregoing warranty and remedy are exclusive and in lieu of all after delivery.