Download Print this page

Toshiba MV13K2R Service Manual page 22

Advertisement

Alignment Tape
ST-N5
ST-NF
VTR cleaning kit
JG022 Master Plane
Tentelometer
Part No.
JG002B
JG002E
JG002F
JG153
JG022/JG024A
JG154
How to use the Servicing Fixture
1.
Unplug the connector CP353, CP354, then remove the TV/VCR Block from the set.
2.
Remove the Operation PCB from the set, then connect it with the Syscon PCB.
If necessary, connect CP353 (Front A/V Jack Input Terminal)
3.
Short circuit between TP1001 and Ground with the cable JG154.
(Refer to MAJOR COMPONENTS LOCATION GUIDE)
4.
The EOT, BOT and Reel Sensor do not work at this moment.
At that time, the STOP/EJECT button is available to insert and eject the Cassette Tape.
SERVICING FIXTURES AND TOOLS
Back tension cassette gauge
70909103
VTR lubrication kit
JG024A Reel Disk Height
Adjustment Jig
VSR Torque, Brake Torque (S Reel/T Reel Ass'y)
Brake Torque (T Reel Ass'y)
VSR Torque, Brake Torque (S Reel)
X Value Adjustment
Reel Disk Height Adjustment
Used to connect the test point of SERVICE and GROUND
PREPARATION FOR SERVICING
Torque cassette gauge
(KT-300NR)
70909199
Grease
JG153 X Value Adjustment
Screwdriver
Remarks
Taper nut driver
70909228
JG002B
Adapter
JG002E
Dial Torque Gauge
(10~90gf•cm)
JG002F
(60~600gf•cm)
JG154 Cable

Advertisement

loading