Serial ATA BIOS Setting Utility Introduction

A.RAID Levels
RAID (Redundant Array of Independent Disks) is a method of combining two hard disk drives into one
logical unit. The advantage of an Array is to provide better performance or data fault tolerance. Fault
tolerance is achieved through data redundant operation, where if one drives fails, a mirrored copy of the
data can be found on another drive. This can prevent data loss if the operating system fails or hangs. The
individual disk drives in an array are called .members. The configuration information of each member is
recorded in the .reserved sector. that identifies the drive as a member. All disk members in a formed disk
array are recognized as a single physical drive to the operating system.
Hard disk drives can be combined together through a few different methods. The different methods are
referred to as different RAID levels. Different RAID levels represent different performance levels, security
levels and implementation costs. The RAID levels which the VIA VT8237 southbridge chipset supports
are RAID 0, 1, and JBOD.
RAID 0 (Striping)
RAID 0 reads and writes sectors of data interleaved between multiple drives. If any disk member fails,
it affects the entire array. The disk array data capacity is equal to the number of drive members times the
capacity of the smallest member. The striping block size can be set from 4KB to 64KB. RAID 0 does
not support fault tolerance.
RAID 1 (Mirroring)
RAID 1 writes duplicate data onto a pair of drives and reads both sets of data in parallel. If one of the
mirrored drives suffers a mechanical failure or does not respond, the remaining drive will continue to
function. Due to redundancy, the drive capacity of the array is the capacity of the smallest drive. Under
a RAID 1 setup, an extra drive called the .spare drive. can be attached. Such a drive will be activated
to replace a failed drive that is part of a mirrored array. Due to the fault tolerance, if any RAID 1 drive fails,
data access will not be affected as long as there are other working drives in the array.
JBOD (Spanning)
A spanning disk array is equal to the sum of the all drives when the drives used are having different
capacities. Spanning stores data onto a drive until it is full, then proceeds to store files onto the next drive
in the array. When any disk member fails, the failure affects the entire array. JBOD is not really a RAID
and does not support fault tolerance.