Fetal Doppler
Operation Manual
:
MODEL
i100

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fetal Doppler i100

  • Page 1 Fetal Doppler Operation Manual MODEL i100...
  • Page 2 T O L i s t e n A n g e l ' s H e a r t b e a t...
  • Page 3: Table Of Contents

    Contents Chapter one Userattention............1 Chapter two Safety instructions...........2 Chapter three Product introduction..........4 3.1 review.................4 3.2The instrument features..........4 Intended use..............4 The standard configuration........4 Chapter four Product appearance..........5 host..............5 Display icon ...............5 Controlling Keys............6 4.4 Indicator light..............6 4.5 probes................6 Chapter Five Basic operation.............7 Used to prepare............7...
  • Page 4 Chapter Maintenance and troubleshooting......9 6.1 maintenance..............9 6.2 troubleshooting............9 Chapter seven Warranty and after-sales service......11 7.1 The warranty...............11 7.2 After-sales service............11...
  • Page 5: Chapter One Userattention

    Chapterone User attention Please read the manual carefully before using and notice the notice, the information prompt and the warning. 1.This manual if there is any modification, and software upgrades, the contents of this manual contains advice can not be making changes, without the prior written consent, should not be allowed to copy or any part of this manual translated into other languages.
  • Page 6: Chapter Two Safety Instructions

    GB 9706.1-2007 to allow the leakage current and dielectric strength. Carefully check the Fetal doppler (the instrument) and the attachment to ensure that the host and accessories have no visible impact on patient safety and instrument performance. The recommended check period is once a week.
  • Page 7 laboratory testing, clinical trials and clinical applications, it is safe to ensure that the doppler energy of this instrument is safe for fetuses, pregnant women and others. However, it is not appropriate to use this instrument for a long time or for a long time. 2.Don't throw the battery into the fire to prevent the explosion from being dangerous.
  • Page 8: Chapter Three Product Introduction

    This instrument is a high-performance fetal heart rate test instrument for the detection of fetal heart rate. This instrument consists mainly of main engine and ultrasonic doppler probe. 3.2 Product FeaturesFunction Different models have different features as follows. Function i100-I i100-II i100-III i100-IV Display Colour...
  • Page 9: Chapter Four Product Appearance

    ( 7 ) volume down ( 8 ) Probes ( 9 ) Battery cover ( 10 ) Probe connection port To display the meaning of the object 4.2.1 i100-I Show the number of placental heart rate and work parameter. 4.2.2 i100-LED Display menu, heart rate number, heart rate curve and working parameters.
  • Page 10: Controlling Keys

    Battery capacity There is no fetal heart rate or no fetal heart signal Alarm on/off Voice volume Number of fetal movements Bluetooth at work Controlling Keys 4.3.1 The volume button When the instrument is turned on or at work, if the sound is too small, the volume control will rotate downward, increasing the volume.
  • Page 11: Chapter Five Basic Operation

    Chapter Five Basic operation Used to prepare Check the equipment for damage and the attachment is intact.If not in good condition,please stop using the instrument and contact the local distributor immediately. Keep the packaging material for future transportation or storage. To use the battery 5.2.1 The installation battery Flip the instrument, turn on the battery cover, and press the battery to the positive...
  • Page 12: Power Off

    5.5.4 The alarm switch:Used to set alarm function. 5.5.5 The voice switch : It is used to set up the speech function, in the open condition, after the fetal heart data is stable, the instrument broadcasts the fetal heart rate once every 8 seconds. 5.5.6 Storage function:used to store fetal heart rate data.
  • Page 13 Chapter Maintenance and troubleshooting Maintenance Please turn off the Close the machinebefore cleaning and remove the battery from the host.Use a soft cloth to wipe off the remaining coupling agent on the probe.Keep the outer surface of the instrument clean, and there is no dust. ( Including LCD display )。...
  • Page 14 Solution: ( 1 ) Adjust the sound up big; ( 2 ) The battery recharges or changes the battery; ( 3 ) Apply enough the coupling agent. 6.2.3 noise main reason: ( 1 ) probes too close to the host; ( 2 ) Interference of external signals; (...
  • Page 15 chapter seven Warranty and after-sales service 7.1 The warranty The warranty liability of this product is limited or the replacement of an examination certificate is within the warranty period and the warranty scope the whole machine or part. The following is not covered under warranty: (...