Gestetner 27AO Technical Manual

Gestetner 27ao: technical manual
Hide thumbs Also See for 27AO:

Advertisement

Quick Links

RW-470
T e c h n i c a l
M a n u a l
Final Version

Advertisement

Table of Contents
loading

Summary of Contents for Gestetner 27AO

  • Page 1 RW-470 T e c h n i c a l M a n u a l Final Version...
  • Page 2 Trademarks   Adobe , Acrobat , PostScript Adobe Systems Incorporated. Apple, Macintosh, Mac and TrueType are registered trademarks of Apple Computer, Incorporated.  AutoCAD and DWG are registered trademarks of Autodesk, Inc. HPGL, HPGL/2 and HP-RTL are registered trademarks of Hewlett-Packard Company. ...
  • Page 3: Table Of Contents

    CONTENTS Contents Technical Manual...4 Package list ...4 System requirements...5 Memory requirements ...6 Printer Controller RW-470 ...7 Technical Data ...7 Installing the Controller into your PC ...8 Troubleshooting ...8 Frequently asked questions ...10 Overview of the file formats...14 Additional font paths...17 Producing SSL files ...18 Structured commands ...18 SSL commands ...20...
  • Page 4: Technical Manual

    Technical Manual This technical manual explains some problem solutions, pro- vides you with technical data and background information for the RW-470 plot management system programs. We wish you every success in working with the RW-470 pro- grams. Package list The delivery includes •...
  • Page 5: System Requirements

    System requirements Please read through the following recommendations carefully. They can be very helpful in finding the optimum hardware for your needs. • Operating system: Microsoft Windows 2000 Professional with ServicePack 1 or higher • Processor: Pentium III, 800 Mhz or higher. •...
  • Page 6: Memory Requirements

    • Monitor: At least 1024 x 768 pixels resolution Memory requirements In the following chart the possible sizes of plots were calculated. The sizes of plots depend on the size of the main memory. In the first chart you can see the results for documents with an av- erage complexity and in the second the results for documents with high complexity.
  • Page 7: Printer Controller Rw-470

    PCI style Bus-Width max. PCI bus clock physical dimension PCB dimension power supply max power consumption max memory on board Connection to copier max. cable length fault tolerance onboard processor copier interface PC resources scanning plotting max pix per line...
  • Page 8: Installing The Controller Into Your Pc

    Changes to the Controller RW-470 are possible and the manu- facturer does provide separate information of them. The technical specifications comply with Installing the Controller into your PC Note: The Printer Controller RW-470 is – like all other high integrated circuits – sensitive to electrostatic charge.
  • Page 9 PRINTER CONTROLLER RW-470 If the kernel driver (device driver) „Printer Controller RW- 470Drv“ is not running: Start event-viewer START->Programs- >Administration->Eventviewer and find out reason for failure. Only if the PRINTER CONTROLLER RW-470DRV Driver is run- ning, you can use the controller. RW-470...
  • Page 10: Frequently Asked Questions

    Frequently asked questions This chapter contains an overview of which commonly asked questions can arise when working with RW-470 PLOTBASE and how you can solve them. See also the explanations about “error messages” in the RW-470 PLOTBASE manual. The topics are arranged in groups under terms, which are sorted alphabetically: •...
  • Page 11 d. Carry out a “Test plot“, to check correct function of the plotter. For that select “Job – Test Print”. e. Check whether the “Interrupt“ switch at the scanner display has been activated. Deactivate it. Check the connection cable between the scanner and server.
  • Page 12 format. Either you enter the gray scale for each individual color in percent or you set pens the pens to “Gray“ and enter the required percentage value. • Lines are not visible If the file to be plotted is in a HPGL or Calcomp format, the color can be set too light or the pen widths are too small.
  • Page 13 FREQUENTLY ASKED QUESTIONS 2. Note the minimum pen widths when scaling. C.f. Pen widths. • Pen widths Ensure that you observe the minimum pen widths for vector images. Scaling a drawing smaller and scaling the pen widths too can lead to loss quality and information in the printout.
  • Page 14: Overview Of The File Formats

    Overview of the file formats In the following chart all file formats are listed. The standard formats are listed in the first chart and the optional formats are listed in the second chart. In the column „Read“ you can see, which file format can be opened and read.
  • Page 15 CALS DODISS, De- partment of Defense Index of Specifica- tions and Standards MIL-STD- 1840B MIL-STD- 28002A „SDN 84-007 / Version 3.2.0“, Inter- graph Corpo- ration HPGL, „The HPGL HPGL/2 and HPGL/2 command set“, Hewlett Packard HP-RTL „HP-RTL, Raster Transfer Language“, Hewlett Pack- Calcomp „Calcomp 906/907...
  • Page 16 The following file formats are optional. You can use the DWG format only, if you have installed an AutoCAD program on your Autodesc “RW-470PS 470PS Level III Com- patible Op- tion” „NIST CGM ATA, Release 2.0“, National Institute of Standards and Technology, Gaithersburg, MD 20899...
  • Page 17: Additional Font Paths

    Additional font paths To enter additional font paths and thus additional fonts proceed (if you are the administrator) as follows: 1. Open the registry editor. Select the following file: \\HKEY_LOCAL_MACHINE\SOFTWARE\RW- 470\PLOTBASE\PLOTSERVER\3.0\FORMATS\RW-470PS EPS\ FontPath Open an edit dialog by double clicking on the file name. 2.
  • Page 18: Producing Ssl Files

    Producing SSL files The structure and commands of the SSL files are described in this chapter. You can use the SSL commands to configure the print job yourself. There are three classes of SSL commands: Structured commands, SSL commands and parameters. This description explains the structured commands first, there then follows an alphabetical list of the SSL commands with the corresponding parameters.
  • Page 19 EndOutput EndJob Example 2: BeginJob Copyright CreationAppl Comment JobName UserName Account Notes Distribution Copies JobCollate JobFlagSheet ; Input Defaults OrigDirectory HpglPens FileEmulation ; Output Defaults Stamp Zoom Rotate BeginOutput Stamp Zoom Rotate MediaType Name EndOutput Floorplan "1998 Schmidt" "BSP R1.01" Job Settings "TEST_1"...
  • Page 20: Ssl Commands

    BeginOutput Stamp Name EndOutput EndJob SSL commands For each SSL command you will find descriptions, which are la- beled with the abbreviations SC, C, SY, D. They mean the fol- lowing: • SC (Scope): This describes where the command can be placed.
  • Page 21 Any number of symbols (including none) by round brackets with asterisk: ( <Digit> )* More than one symbol with round brackets with Plus : ( <Digit> )+ One or no symbols with round brackets with question mark: ( <Whitespace> )? A normal arithmetic bracket is also round: ( a | b ) •...
  • Page 22 = any text, which is stored in the archive, to label the draw- ing. Any alphanumeric string is valid. SY = ArchiveReference <string> = – CalComp SC = JOB, ENTRY = settings for Calcomp files SY = CalComp ( <calcomp> )+ <calcomp>...
  • Page 23 <custompen> = ( number ( <int> | <int> - <int> | all ) <pensettings> )+ <pensettings> = width <real> color <int> saturation <per- cent> ( pattern <patterntype> )? <patterntype> = circle | random = off Comment or ‘;’ SC = JOB, ENTRY = any comment up to the end of the row is ignored and is lost when processed by the program.
  • Page 24 = – CostCenter SC = JOB = Text, which identifies the account. Interesting for an ac- counting module. SY = CostCenter <string> = – CreationAppl SC = JOB = Text, which identifies the generating applications. SY = CreationAppl <string> = – Customer SC = JOB = Text, which identifies the job’s customers.
  • Page 25 SY = DeleteAfterPlot ( on | off ) = off Directory SC = ENTRY = The directory, in which the plot file is, absolute paths are not currently possible, therefore, SSLs can not be simply copied with your image directories. SY = Directory <string>...
  • Page 26 = Gives the file format of the plot file, if auto, the plot soft- ware decides which format is available. SY = FileEmulation ( auto | CalComp | CALS | HPGL | HPGL2 | PCX | TIFF | RLC | MTF ) = auto HeaderPosition SC = JOB, ENTRY...
  • Page 27 green, 2 = blue dithermode: for HPGL / RTL SY = Hpgl ( <HpglStatement> )+ <HpglStatement> = ( filepensize ( on | off ) ) | ( filepcolor ( on | off ) ) | ( penscale ( on | off ) ) | ( minwidth <real> ) | ( maxwidth <real>...
  • Page 28 = inverts the plot SY = Invert ( on | off ) = off JobCollate SC = JOB = on: Sorts the plots in sets ( 123123); off: Prints the same plots after only effective if SetCopies > 1: SY = JobCollate ( on | off ) = on JobFlagsheet SC = JOB...
  • Page 29 SY = JobName <string> = – JobPlotter SC = JOB = Controls the printout on a certain plotter, if several plot- ters are connected to the plot server ( PLOTSERVER ) SY = JobPlotter ( auto | <string> ) = auto JobPriority SC = JOB = Priority of the jobs in the queue...
  • Page 30 = exact MediaPosition SC = JOB, ENTRY = Position of the plot on the paper. SY = MediaPosition ( auto | <position> ) <position> = ul | upperleft | uc | uppercenter | ur | upper- right | lc | leftcenter | cc | centercenter | rc | rightcenter | bl | bottomleft | bc | bottomcenter | br | bottomright = ul...
  • Page 31 Notes SC = JOB, ENTRY = Comment on job / Plot, is retained during processing SY = Notes <string> = – OnError SC = JOB = Reaction to errors; abort = abort set and continue with the next set; continue = continue with the next entry; query = display message and hold the plot until operator inter- cedes.
  • Page 32 SY = OrigName <string> = – OutputBin This is for the Input tray. SC = JOB, ENTRY = Roll to be plotted from. SY = OutputBin ( auto | manual | Bin <int> ) = auto OutputSize SC = JOB, ENTRY = choice of the paper format.
  • Page 33 if e.g. only one tray is accessible. front / rear: the specific output SY = OutputTray ( auto | default | front | rear ) = auto Pens SC = JOB, ENTRY = now → HpglPens Placement SC = JOB, ENTRY = Position of the plot on the paper: in x and y co- ordinates, or as a simple position SY = Placement ( <real>...
  • Page 34 = – Rotate SC = JOB, ENTRY = Rotate the image SY = Rotate ( auto | 0 | 90 | 180 | 270 ) = auto SecurityPrint This is for “Locked Print”. SC = JOB = The set remains in the queue and is not plotted, until a password is entered.
  • Page 35 Name and path of the image. bmporientation : where is the image with relation to the stamp text. bmpdis- tance : Distance between stamp text – stamp image. framesize : Thickness of the frame surrounding the stamp. frametextdistance : Distance of the frame from the text.
  • Page 36 SC = JOB = The first copy of the set is plotted, then an operator input is waited for, to say whether the other copies are also to be printed. SY = TrialPrint ( on | off ) = off Units SC = JOB = Unit of the job size information.
  • Page 37: Producing Cfg Files

    PRODUCING CFG FILES Producing CFG files This chapter explains the CFG file structure and commands. CFG files are usually produced normally automatically and are sent with the corresponding drawing files to the RW-470 PLOTBASE. They contain the settings for the print off. You can use the CFG commands explained in this chapter to produce your own CFG file.
  • Page 38 A CFG file contains the following entries: ENTRY VALUES INPUTBIN AUTO 1..n COPYCOUNT 1..999 ROTATE AUTO INVERT MIRROR FOLD 1..xx SCALEMODE ORIGINAL PERCENT FORMAT WINDOW SCALEAUX1 ORIGINAL: not used PERCENT Percent times 100 FORMAT: DIN A0..DIN A6 WINDOW: Width in 1/1200 inches SCALEAUX2 WINDOW:...
  • Page 39 ORIGINALFILE CALCOMP Pen width of the pen PEN01 01 in 1/1000 mm CALCOMP 0..32Pixel PEN02..PEN16 STEPSPERCM 1..9999 CCCHECK CCSYNC01 <Characters> CCSYNC02 <Characters> CCENDCHAR <Characters> HPGL / HPGL2 0..9.99 mm, PEN000 <COLOR> HPGL / HPGL2 0..9.99 mm, PEN001 <COLOR> HPGL / HPGL2 0..9.99 mm, PEN002..PEN255 <COLOR>...
  • Page 40 BORDERTOP 0..xxxx BORDERBOTTOM 0..xxxx BORDERLEFT 0..xxxx BORDERRIGHT 0..xxxx RW-470 Borders in mm as above as above as above...
  • Page 41: Hpgl/2 Commands And Pens

    HPGL/2 commands and pens In this chapter we have listed all the HPGL/2 commands that the program fully or partially supports: + = command is fully supported ~ = command is partially supported • Configuration and status group: DF = IW = PG = RO =...
  • Page 42 • Line and Fill Attributes Group: • Character Group: • Technical Graphics Extensions: RW-470...
  • Page 43 • Palette Extension: • Dual-Context Extension: No commands are supported • Digitizing Extension: No commands are supported • Default values for HPGL pens: All 256 HPGL pens have the pen thickness 0.35 mm as their default value. They have the following default values as colors: Color white black...
  • Page 44: Calcomp Commands And Pens

    Calcomp commands and pens In this chapter we have listed all the Calcomp commands and their implementation status in RW-470 PLOTBASE. The standard pen widths for the 16 Calcomp pens are given at the end of the chapter. + = command is fully supported −...
  • Page 45 • Symbols Commands: font selection symbol string count plotter symbol scaling controller symbol scaling symbol characteristics extended characters select symbol set 0-4 plotting symbol from selected symbol set + user defined symbol erase user symbol set • Circles Commands: chordal tolerance circle command for circles circle command for arcs •...
  • Page 46 Pen width in mm RW-470 Pen width in pixels 0.25 0.32 0.38 0.44 0.51 0.57 0.64 0.70 0.76 0.83 0.89 0.95 1.02...
  • Page 47: Registry Entries

    REGISTRY ENTRIES Registry entries In the registry editor you can alter several sub-trees for RW-470 PLOTBASE. The following lists a selection of entries from the registry editor, which can be entered during the installation of RW-470 PLOTBASE and can then be changed by you. However, not all the entries have been listed, as either some of them should not be changed by you or they occur several times with respect to their meaning.
  • Page 48 REGISTRY ENTRIES Type:REG_SZ Data: 00000000 [Comment: 0: At the end of the roll only use identical roll, oth- erwise wait,1: At end of roll only use compatible roll, otherwise wait}] Name: SpoolTimeout Type:REG_DWORD Data: 00000000 [Comment: Timeout for incomplete jobs in seconds] Name: Dao Type:STRING Data: C:\RW-470\PLOTBASE\PROGRAM\CBDB.mdb...
  • Page 49 REGISTRY ENTRIES Data: 00000000 [Comment: Percentage, how much HDD capacity can be used by the plot server] Name: ErrorHandling Type:REG_DWORD Data: 00000000 [Comment: Strategy for errors that occur: 0: In case of error do not plot any further jobs,1: In case of error plot next jobs] Name: JobHistoryDeleteCapacity Type:REG_DWORD Data: 00000001...
  • Page 50 REGISTRY ENTRIES Name: LogFileName Type:STRING Data: %temp\\COPYBASELoggingPlot [Comment: Path + Name of the log file, if switched on (for er- ror detection)] Name: Logging Type:REG_DWORD Data: 00000000 [Comment: logging on/ off] Name: Server Type:STRING Data: RW-470 PLOTBASE - Server [Comment: Name of the plot server] Name: ServerExe Type:STRING Data: C:\RW-470\PLOTBASE\PROGRAM\PbDbRu.exe...
  • Page 51 REGISTRY ENTRIES Type:REG_DWORD Data: 00000000 [Comment: FilePrint on/ off- if on, then plot to file] Name: View Type:STRING Data: PLOTBASE - UI [Comment: Name of the plot server controller] Name: ViewOn Type:REG_DWORD Data: 00000001 [Comment: Fileview on/ off] Name: DBOn Type:REG_DWORD Data: 00000001 [Comment: internal value for the start of the controller and the...
  • Page 52 REGISTRY ENTRIES Name: ResponsePath Type:STRING Data: C:\SPOOL\response [Comment: Path for Response file (uses RW-470 PLOTCLIENT WEB)] Name: FilePrintDestination Type:STRING Data: f:\\fileprint [Comment: if UseFilePrint = 1, directory, where the FilePrint is to be written to] Name: Logging Type:REG_DWORD Data: 00000000 [Comment: 1: If logging switched on, 0: Logging switched off] Name: LogLevel Type:REG_DWORD...
  • Page 53 REGISTRY ENTRIES Type:REG_DWORD Data: 00000000 [Comment: Direction of the drawing rotation, clockwise or anti- clockwise] Name: SizeTolerance [mm] Type:REG_DWORD Data: 00000002 [Comment: If the printout is this value larger than the roll avail- able, then nevertheless plotted] Key name:SOFTWARE\ RW-470\PLOTBASE \ PLOTSERVER\ 3.0\PBWnd These values give the colors of the jobs in the job list.
  • Page 54 REGISTRY ENTRIES Name: ColorSecurityPlot Type:REG_DWORD Data: 00ff8000 [Comment: Color for “Password“ status] Name: ColorTrialPrint Type:REG_DWORD Data: 00ff8000 [Comment: Color for “Test Print“ status] Key name: SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.0\ PBReader\Config\Registration Name: ConfigCount Type:REG_DWORD Data: 00000002 [Comment: Number of spool paths] Key name:SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.0\ PBReader\Config\Registration\0 [Comment: settings for the first spool path] Name: TypeName Type: REG_SZ...
  • Page 55 REGISTRY ENTRIES Name: ConfigParserTime Type:REG_DWORD Data: 00001388h [Comment: Timeout for the parser] Name: ConfigReadyFile Type:REG_DWORD Data: 00000000 [Comment: Activate Ready File Action; 0: False, 1:True] Name: ConfigParserOn Type:REG_DWORD Data: 00000001 [Comment: Activate reader; 0: False, 1:True] Name: ConfigDefSSLFile Type: REG_SZ Data: default.ssl [Comment: Name of the default SSL file] Name: ConfigDefCFGFile...
  • Page 56 REGISTRY ENTRIES [Comment: Reference to the reader types] Name: ConfigWindowName Type:REG_DWORD Data: SSL [Comment: Name of the input queue] Name: ConfigParserPath Type: REG_SZ Data: F:\\SPOOL\\SSL [Comment: Spool path] Name: ConfigParserTime Type:REG_DWORD Data: 00001388h [Comment: Timeout for the parser] Name: ConfigReadyFile Type:REG_DWORD Data: 00000000 [Comment: Activate Ready File Action;...
  • Page 57 REGISTRY ENTRIES Key name: SOFTWARE\RW-470\PLOTBASE\ PLOTSERVER\3.0\ PBReader\Type\Registration Name: ReaderCount Type:REG_DWORD Data: 00000002 [Comment: Number of reader types] Key name: SOFTWARE\RW-470\PLOTBASE\ PLOTSERVER\3.0\ PBReader\Type\Registration\0 [Comment: settings for a reader type] Name: TypeExePath Type: REG_SZ Data: C:\RW-470\PLOTBASE\PROGRAM\ReSslru.exe [Comment:Path of the reader] Name: TypeName Type: REG_SZ Data: SSL - Interpreter [Comment: Name of the reader]...
  • Page 58 REGISTRY ENTRIES Name: TypeExePath Type: REG_SZ Data: C:\RW-470\PLOTBASE\PROGRAM\ReCfgru.exe [Comment: Reader path] Name: TypeName Type: REG_SZ Data: CFG - Interpreter [Comment: Reader name] Name: TypeReadyFilePossible Type:REG_DWORD Data: 00000001 [Comment: Setting, whether the Reader ReadyFiles are proc- essed; 0:False, 1:True] Name: TypeWithDeaultSsl Type:REG_DWORD Data: 00000001 [Comment: Setting, whether a default SSL is used;...
  • Page 59 REGISTRY ENTRIES Data: C:\RW-470\PLOTBASE [Comment:Path for RW-470 SCANTOOL] Name: Path Type: REG_SZ Data: C:\RW-470\SCANTOOL\samples\ [Comment:last path used in the file selection] Name: LastFilterRead Type:REG_DWORD Data: 00000001 [Comment: saves the file extension that was last used, do not change] Name: ScannerDriver Type: REG_SZ Data: SeIfD1Ru.dll [Comment: File name of the scanner driver]...
  • Page 60 REGISTRY ENTRIES Name: ScanBaseTempPath Type: REG_SZ Data: C:\DOCUME~1\ADMINI~1\LOCALS~1\Temp\ [Comment:Path of the temporary directory for RW-470 SCANTOOL] Name: EnableScanner Type:REG_DWORD Data: 00000001 [Comment: Switch the scan switch on, off; do not change] Name: ViewBrightness Type:REG_DWORD Data: 000000ffh [Comment: Save the brightness values in the file view] Name: HpglCfgFile Type: REG_SZ Data: C:\RW-470\PLOTBASE\HPGL.HCF...
  • Page 61 REGISTRY ENTRIES Data: 00000000 [Comment: Add scan result to the drawing set; 0:Off, 1:On] Name: ScanToFilePath Type: REG_SZ Data: F:\\ [Comment: Path for ScantoFile files] Name: ScanToFileName Type: REG_SZ Data: SBAUTO [Comment:Name for ScanToFile file] Name: ScanToFileStartNo Type:REG_DWORD Data: 0000002f [Comment: Start number for ScanToFile file] Name: ScanToFileDigits Type:REG_DWORD...
  • Page 62 REGISTRY ENTRIES [Comment: Activation of the “Scanner settings” window; 0:Off, 1:On] Name: StampActive Type:REG_DWORD Data: 00000000 [Comment: Activation of the stamp function; 0:Off, 1:On] Name: StampIFConfigName Type: REG_SZ Data: C:\RW-470\PLOTBASE\SCANTOOL [Comment:Path and basic name of the stamp configurations] Name: StampListConfigCnt Type:REG_DWORD Data: 00000000 [Comment: Number of stamps used;...
  • Page 63 REGISTRY ENTRIES RW-470...
  • Page 64 REGISTRY ENTRIES Key name:SOFTWARE\RW-470\PLOTBASE\ SCANTOOL\3.0\ [Comment: settings for the character set] Name: SSLEntryViewing Type:REG_DWORD Data: 00000001 [Comment: Display of the entries selected in the file view; 0:Off, 1:On] Name: Ssl-Name Type: REG_SZ Data: SCANBASE.SSL [Comment: File name of the last drawing set saved] Key name:SOFTWARE\RW-470\PLOTBASE \ SCANTOOL\3.0\ Splitter\0 [Comment: Window division]...
  • Page 65 REGISTRY ENTRIES [Comment: Only for internal management] Name: CALCOMP_CONFIG_FILE Type: REG_SZ Data: [Comment: This is the path for the Config File, where the basic settings for Calcomp are saved] Key name: SOFTWARE\RW- 470\PLOTBASE\PLOTSERVER\3.0\FORMATS\HPGL / HPGL2 Name: HP-FONTPATH Type: REG_SZ Data: [Comment: This is the path for the Ratio HPGL font files.] Name: HPGL_CONFIG_FILE Type: REG_SZ...
  • Page 66 REGISTRY ENTRIES Name: HP-SETTINGS Type: REG_SZ Data: DATA-STRUCT [Comment: Only for internal management] Key name: SOFTWARE\RW-470\PLOTBASE\PLOTSERVER\3.0\FORMATS\ Intergraph Name: TileDX Type: REG DWORD Data: This is where the tile width is when saving this format, there are no facilities in the application for adjusting this value. [Comment: Default value 512] Name: TileDY Type: REG DWORD...
  • Page 67 REGISTRY ENTRIES Key name: SOFTWARE\RW- 470\PLOTBASE\PLOTSERVER\3.0\FORMATS\Windows Metafile Name: Default Dpi Type: REG DWORD Data: This is where the default Dpi is. [Comment: Default value 400] Name: Default Lpi Type: REG DWORD Data: This is where the default Lpi is. [Comment: Default value 400] Name: Default DX Type: REG DWORD Data: This is where the default image width is with which the...
  • Page 68 [Comment: Default “.;.\Font“ ] Name: IncludePath Type: REG_SZ Data: Additional path for font files [Comment:] Name: Device Type: REG DWORD Data: 0 No color channel 1 Red 2 Green 3 Blue [Comment: Default 0, color channel for BiColorMode] Name: EnableBiColor Type: REG DWORD Data: 0 BiColorMode switched on...
  • Page 69 Data: ComboBox selection (0 - 4) Additional entries possible [Comment: Default 0] Name: HalfToneFrequency Type: REG DWORD Data: 1 - 999 [Comment: Grayscale manipulation] Name: HalfToneManual Type: REG DWORD Data: 0 Manual settings off 1 Manual settings on [Comment: Grayscale manipulation] Name: HalfToneMode Type: REG DWORD Data: 0 Background manipulation...
  • Page 70 REGISTRY ENTRIES [Comment:] Name: PDFSettings Type: REG_SZ Data: DATA-STRUCT [Comment:] Name: UseHalftoning Type: REG DWORD Data: 0 Halftoning switched off 1 Halftoning switched on [Comment: Default 0] Name: UseScaling Type: REG DWORD Data: not used for PDF [Comment: Default 1] Key name: SOFTWARE\RW- 470\PLOTBASE\PLOTSERVER\3.0\FORMATS\RW-470PS / EPS...
  • Page 71 Name: IncludePath Type: REG_SZ Data: Additional path for font files [Comment:] Name: Device Type: REG DWORD Data: 0 No color channel 1 Red 2 Green 3 Blue [Comment: Default 0, Color channel for BiColorMode] Name: EnableBiColor Type: REG DWORD Data: 0 BiColorMode switched on 1 BiColorMode switched off [Comment: Is set internally]...
  • Page 72 [Comment: Default 0] Name: HalfToneFrequency Type: REG DWORD Data: 1 - 999 [Comment: Grayscale manipulation] Name: HalfToneManual Type: REG DWORD Data: 0 Manual settings off 1 Manual settings on [Comment: Grayscale manipulation] Name: HalfToneMode Type: REG DWORD Data: 0 Background manipulation 1 General manipulation 2 Grayscale manipulation [Comment: Grayscale manipulation]...
  • Page 73 REGISTRY ENTRIES Name: RW-470PSSettings Type: REG_SZ Data: DATA-STRUCT [Comment:] Name: UseHalftoning Type: REG DWORD Data: 0 Halftoning switched off 1 Halftoning switched on [Comment: Default 0] Name: UseScaling Type: REG DWORD Data: 0 Scaling switched off 1 Scaling switched on [Comment: Default 1, should usually be switched on.
  • Page 74: Index

    Index Calcomp Commands... 44 Pens ... 45 CE-Certification ... 8 CFG-File Commands... 38 File formats ... 14 Font path ... 17 Front Side Bus ... 5 Hard drive... 5 Hardware... 5 HPGL/2-Commands... 41 Memory ... 6 Monitor ... 6 Network ... 5 RW-470 PCI Bus ...

This manual is also suitable for:

Rw-470

Table of Contents