Firmware: v.2.0 or higher
Input type: voltage
Dedicated for DAQ systems
Read the user's manual carefully before starting to use the unit or software.
Producer reserves the right to implement changes without prior notice.
2015.02.25
User manual
MODULE
SLI-8
Assisting the automation
industry since 1986
SLI-8_INSSXEN_v.1.08.002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLI-8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Simex SLI-8

  • Page 1 Assisting the automation industry since 1986 User manual MODULE SLI-8 Firmware: v.2.0 or higher • Input type: voltage • Dedicated for DAQ systems • Read the user's manual carefully before starting to use the unit or software. Producer reserves the right to implement changes without prior notice.
  • Page 2: Table Of Contents

    User manual - MODULE SLI-8 CONTENTS 1. BASIC REQUIREMENTS AND USER SAFETY..................3 2. GENERAL CHARACTERISTICS........................3 3. TECHNICAL DATA............................3 4. DEVICE INSTALLATION..........................4 4.1. UNPACKING............................5 4.2. CONNECTION METHOD........................5 4.3. MAINTENANCE..........................7 5. PRINCIPLE OF OPERATION........................7 6. THE MODBUS PROTOCOL HANDLING....................9 6.1. LIST OF REGISTERS........................10...
  • Page 3: Basic Requirements And User Safety

    User manual - MODULE SLI-8 1. BASIC REQUIREMENTS AND USER SAFETY - The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment. - Installation should be conducted by qualified personnel . During installation all available safety requirements should be considered.
  • Page 4: Device Installation

    User manual - MODULE SLI-8 Minimum duration of LOW and HIGH state 50 µs Counters capacity 4 294 967 295 (32 bits) Galvanic isolation All inputs are galvanically isolated from module supply and RS-485 interface Communication interface RS 485, 8N1 / Modbus RTU Baud rate 1200 ÷...
  • Page 5: Unpacking

    User manual - MODULE SLI-8 4.1. UNPACKING After removing the unit from the protective packaging, check for transportation damage. Any transportation damage must be immediately reported to the carrier. Also, write down the unit serial number on the housing and report the damage to the manufacturer.
  • Page 6 User manual - MODULE SLI-8 In the case of interference from the power supply side the use of appropriate anti- – interference filters is recommended. Bear in mind that the connection between the filter and the unit should be as short as possible and the metal housing of the filter must be connected to the earthing with largest possible surface.
  • Page 7: Maintenance

    User manual - MODULE SLI-8 4.3. MAINTENANCE The unit does not have any internal replaceable or adjustable components available to the user. Pay attention to the ambient temperature in the room where the unit is operating. Excessively high temperatures cause faster ageing of the internal components and shorten the fault-free time of unit operation.
  • Page 8 User manual - MODULE SLI-8 It is essential that pulses have fulfil some time restrictions - see Figure 5.1). These restrictions depend on settings of internal digital filter implemented in firmware. Filter allows to eliminate signal oscillations corresponding to contacts bouncing (of mechanical sensors). Filter is factory switched off.
  • Page 9: The Modbus Protocol Handling

    User manual - MODULE SLI-8 Forcing of 0xFF address New devices has set to Modbus addresses 0xFE. To enhance system installation process special operation mode has been developed. It allows to force address 0xFF in single module using internal momentary switch mounted on module mainboard (Figure 4.1).
  • Page 10: List Of Registers

    User manual - MODULE SLI-8 6.1. LIST OF REGISTERS Register Write Range Register description Higher byte of counter corresponding to input 1 0000 ÷ FFFFh Lower word of counter corresponding to input 1 0000 ÷ FFFFh Higher byte of counter corresponding to input 2 0000 ÷...
  • Page 11: Transmission Errors Description

    User manual - MODULE SLI-8 6.2. TRANSMISSION ERRORS DESCRIPTION If an error occurs while write or read of single register, then the device sends an error code according to Modbus RTU specifications. Error codes: 01h - illegal function (only functions 03h and 06h are available),...
  • Page 12 FUNC BYTE C DATA H,L CRC L,H DATA H, L - counter's no.4 content equals E41Dh = 58397 4. Simultaneous zeroing of all counters in all SLI-8 modules connected to the network ADDR FUNC REG H,L COUNT H,L CRC L,H...
  • Page 13 User manual - MODULE SLI-8 The answer (the same as the message): ADDR FUNC REG H,L COUNT H,L CRC L,H In the result of that query counter no. 2 will be zeroed. The same result can be obtained by writing 0000h to register 04h.
  • Page 14 User manual - MODULE SLI-8...
  • Page 15 User manual - MODULE SLI-8...
  • Page 16 SIMEX Sp. z o.o. ul. Wielopole 11 80-556 Gdańsk Poland tel.: (+48 58) 762-07-77 fax: (+48 58) 762-07-70 http://www.simex.pl e-mail: info@simex.pl...