It can be installed in all kinds of residential spaces where people work, relax or spend their time. In order to reduce any possible danger to human health and property, the stove Astra is equipped with special safety devices.
(available by special order). Only 6 mm wood pellets are used for fuelling the Astra stove. The appliance is not designed to be operated with any other kind of fuel because other fuels leave a greater content of ashes and slag. The latter then will cause the fire pot to clog, activating emergency stop of the appliance.
Page 5
2004/108/EEC– Electromagnetic compatibility directive; (EU) No 305/2011 – Construction Products Regulation. The following standards were applied for the Astra P-10 pellet stove: EN 14785 – Residential space heating appliances fired by wood pellets; EN 60335-1 – Safety of household and similar electrical appliances;...
Astra P-10 USER MANUAL • CIRCUIT DIAGRAM The electrical circuit diagram of the stove is presented below in Fig. 2. The denomination of elements is as follows: T1 – Room temperature sensor; T2 – Smoke temperature sensor; B1– Electrical (250 W) igniter; M1 – Fan 1- smoke exhaust fan;...
• If another heating installation (stove, fireplace) without autonomous air supply is present in the room of considered placement of the Astra stove, evaluate, whether there would be a sufficient air supply for both appliances working simultaneously and if that kind of double installation is allowed by local technical regulations;...
• The joints of chimney pipes must have temperature resistant gaskets in order to ensure sufficient tightness of the connections; • A separate chimney is mandatory for the Astra stove installation. It is not permitted to connect the stove to a shared flue;...
Page 9
FIG.10 FIG.5 FIG.8 Astra P-10 USER MANUAL Chimney cover plate This type of installation (Fig. 5) does not require Airtight steel sheeting an insulated flue as the smoke pipe is assembled partly inside the house and partly inside an existing flue. A chimney tee with a peephole cap is installed in the lower part of the flue.
Page 10
Astra P-10 USER MANUAL Two 90° bends cannot be assembled the Ashes accumulate in the 90° bend way shown in Fig. 7, because ashes would quickly obstruct a passage for smoke causing unexpected problems for draught of the flue. FIG.8 FIG.7...
Astra P-10 USER MANUAL The minimum height of chimney from the stove’s smoke pipe to the chimney top is 4 meters. The recommended lengths of various parts of combined internal/external flue are presented in Fig. 9. 2500 mm max. Insulated flue...
The remote control unit does not come in a standard delivery kit of a stove. It must be ordered separately. The Astra stove controller consists of two parts: a display and a control board mounted near the base of the stove. The display operates by principle of capacitive touchscreen.
Astra P-10 USER MANUAL The infrared remote control is intended for day-to-day use when the combustion system is fully configured and operational. It is used for changing the burning power and temperature settings, turning the combustion in the stove on and off.
Astra P-10 USER MANUAL • MENU STRUCTURE The menu structure tree (Fig. 11) exhibits all consisting menu entries. The values of parameters are chosen for purpose of illustration only. The buttons used to reach a particular menu entry are depicted near it.
Page 15
Astra P-10 USER MANUAL With buttons set the end time value. Press With buttons set the desired temperature of the program. Press confirmation. (the third, fourth, fifth programs are skipped for the purpose of illustration) Sixth program. Press button and enter the desired values.
Astra P-10 USER MANUAL P1 Program P2 Program P3 Program P4 Program P5 Program P6 Program On Off On Off On Off On Off On Off On Off 23:00 4:30 4:30 7:30 17:00 23:00 00:00 7:30 7:30 24:00 7:30 23:00 16°C...
Astra P-10 USER MANUAL The anti-freeze mode is operational only with the weekly timer mode. The timer programs can be undescribed but the timer mode must be switched on. The current temperature of smoke is shown on the screen. The current value of the smoke temperature.
Astra P-10 USER MANUAL • REGULATION OF THE ROOM VENTILATOR The controller enables you to change the rotational speed of the room ventilator. There are six levels of the speed: . We recommend you to let the stove itself decide upon the rotational intensity.
Astra P-10 USER MANUAL Beeper volume setting enables the user to change the volume of the display signals from 1 to 5 or switch the beeper off. The beeper is off. The sound level is 1. The sound level is 5.
Astra P-10 USER MANUAL • All stove components and ashes have cooled down sufficiently; • Suitable tools will be used for cleaning; • The electrical cable is unplugged when flue channels are to be cleaned. When cleaning the combustion chamber, be careful and do not clog the pressure sensor’s pipe which is...
Page 21
Astra P-10 USER MANUAL Fig. 17a Fig. 17 Removing the top cover of the stove. Fig. 18a Fig. 18b Fig. 18c Fig. 18 Opening the inspection hatches of the flue channels.
• VERMICULITE PLATES CLEANING The combustion chamber of the Astra pellet stove is lined with five vermiculite plates (Fig. 15). Vermiculite has high resistance to heat, is lightweight and has excellent insulation properties.
Astra P-10 USER MANUAL who has installed the stove. Use a drum-type vacuum cleaner only. The flue of the stove has two channels: at the left and at the right side of the combustion chamber. These channels join together into one smoke passage box near which the exhaust fan 16 (Fig.
Astra P-10 USER MANUAL 10. TROUBLESHOOTING The stove display provides warnings for alerts and errors which can occur during the operation of the controller. The alarm icons in the indicator line of the display signal a problem. An alert notification is indicated by blinking icons, errors are indicated with continuously lit icons.
Astra P-10 USER MANUAL • ERRORS Service required Indication: Code Cause: The combustion Solution: note the error E001: Keyboard error Icon Service lights system has malfunctioned code and contact service E002: IR communication error constantly and not operational. personnel. E003: RF communication error...
• all the warranty obligations of the manufacturer are listed in this chapter; the manufacturer cannot be held responsible for additional obligations undertaken by third parties. 12. ACCEPTANCE CERTIFICATE The stove Astra P-10, serial No........, conforms to the technical documentation, requirements of the standard EN 14785 and is approved as fit for operation. Manufacturing date 201 ..............
Astra P-10 USER MANUAL Other information concerning installation: ................................................................................................................The pellet stove was tested on site, the control and safety elements were checked and found to be operating properly. Person responsible for installation and testing: ............................. (Name, surname, signature of the employee) I accept the installation works: ................................
2004/108/EEC– Electromagnetic compatibility directive; (EU) No 305/2011 – Construction Products Regulation. The following standards were applied for the Astra P-10 pellet stove: EN 14785 – Residential space heating appliances fired by wood pellets; EN 60335-1 – Safety of household and similar electrical appliances;...
Need help?
Do you have a question about the P-10 and is the answer not in the manual?
Questions and answers