Page 2
Please use with caution. All information is subject to change without notice This product contains some codes from GPL. In compliance with GPL agreement, AirLive will publish the GPL codes on our website. Please go to www.airlive.com and go to the "Support->GPL" menu to download source code.
Page 3
When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. AirLive SI-104 User Manual...
The device adopts the Z-Wave 500 series chip, when your Z-Wave network system is all made by Z-Wave 500 series devices. The network system will have the advantages as below. • Concurrent multi-channel support reduces external interference. AirLive SI-104 User Manual...
2. Pressing tamper key three times within 1.5 seconds to enter the association mode. Association Note: The device supports 1 group. This group is for receiving the report message, like triggered event etc. These groups support 8 nodes maximum. AirLive SI-104 User Manual...
Smoke Sensor test (0x03) report to the nodes in the group 1. Notification Report (V4) Notification Type: Smoke (0x01) Event: Smoke detected, Unknown Location (0x02) Smoke Alarm Test (0x03) Sensor Binary Report (V2) AirLive SI-104 User Manual...
Let the controller into the firmware update mode, and then press the button once to start the update. Please don't remove the battery, otherwise it will cause the firmware broken, and the device will no function. AirLive SI-104 User Manual...
Smoke Sensor does not go into alarm, test it by pressing the test button to ensure if it works properly. Notice : To keep the Smoke Sensor in good working condition, testing the device weekly is necessary. AirLive SI-104 User Manual...
1. Install Smoke Sensor as close to the center of ceiling as possible. If this is not practical, put the sensor on the ceiling, no closer than 4inches(10 cm) from any wall or corner. AirLive SI-104 User Manual...
Install Smoke Sensor at least 5 feet (1.5 meters) from such lights. 1.11 Installation At the place where you are going to install your Smoke Sensor, draw a horizontal line six inches long. Remove the mounting bracket from your device by rotating it counterclockwise. AirLive SI-104 User Manual...
The reserve bit or not supported bit is allowed any value, but no effect. NO. Name Def. Valid Description 7(*) Customer Customer function switch, using bit control. Function Bit0: Reserve. Bit1: Reserve. Bit2: Reserve. Bit3: Reserve. Bit4: Notification Type, 0: Using Notification Report. AirLive SI-104 User Manual...
Need help?
Do you have a question about the Z-Wave Plus SI-104 and is the answer not in the manual?
Questions and answers