Electrolux EFLW317TIW Installation Instructions Manual page 4

Hide thumbs Also See for EFLW317TIW:
Table of Contents

Advertisement

Available languages

Available languages

4
Installation Requirements
Electrical system requirements
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt
single phase, 60 Hz, Alternating Current.
NOTE
Because of potentially inconsistent voltage
capabilities, the use of this washer with power
created by gas powered generators, solar
powered generators, wind powered generators
or any other generator other than the local
utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded
3-prong receptacle to be located so the
power supply cord is accessible when the
washer is in an installed position.
Grounding
Grounding
type
type
wa
wall ll
receptacle
receptacle
Grounding requirements
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment
grounding conductor can result in a risk
of electrical shock. Check with a licensed
electrician if you are in doubt as to whether
the appliance is properly grounded.
1. The washer MUST be grounded. In the event
of malfunction or breakdown, grounding will
reduce the risk of electrical shock by a path
of least resistance for electrical current.
2. Since your washer is equipped with a power
supply cord having an equipment-grounding
conductor and a grounding plug, the plug
MUST be plugged into an appropriate, cop-
per wired receptacle that is properly installed
and grounded in accordance with all local
codes and ordinances or in the absence
of local codes, with the National Electrical
Codes, ANSI/NFPA 70 (latest edition), or in
Canada, the Canadian electrical code C22.1
part 1. If in doubt, call a licensed electri-
cian. DO NOT cut off or alter the grounding
prong on the power supply cord. In situations
where a two-slot receptacle is present, it is
the owner's responsibility to have a licensed
electrician replace it with a properly ground-
ed three prong grounding type receptacle.
Do not, under any circumstances,
Do not, under any circumstances,
cut, remove, or bypass the
cut, remove, or bypass the
grounding prong.
grounding prong.
Po Power cord
wer cord
with 3-prong
with 3-prong
gr grounded plug
ounded plug
Water supply requirements
Hot and cold water faucets MUST be installed
within hose length of your washer's water inlet.
The faucets MUST be 3/4 inch (1.9 cm) with
threading for laundry hose connection. Water
pressure MUST be between 20 and 120 psi. Pres-
sure diff erence between hot and cold cannot
be more than 10 psi. Your water department can
advise you of your water pressure.
Drain system requirements
1. Drain capable of eliminating 17 gals (64.3 L)
per minute.
2. A standpipe diameter of 1-1/4 in. (3.18 cm)
minimum.
3. The standpipe height above the fl oor should be:
Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)
96"
(244 cm)
max.
24"
(61 cm)
min.
NOTE
Drain hose length is 59 in. (150 cm). For
installations requiring a longer drain hose,
use hose P/N 137098000, available from an
authorized parts distributor.

Advertisement

Table of Contents
loading

Table of Contents