Advertisement

Quick Links

OFRC10TI
OFRC10, OFRC15, OFRC20, OFRC25
OFRC10TI, OFRC15TI, OFRC20TI & OFRC25TI
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
As with all portable heating appliances - This product is only suitable for well insulated spaces or occasional use
08/19819/0 (UK)
Issue 6
The product complies with the European Safety Standards EN60335:2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014:1,
EN55014:2, EN61000:3-2 and EN61000:3-3 which cover the essential requirements of EMC Directive 2014/30/EU and the LVD Directive 2014/35/EU.

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex OFRC15

  • Page 1 OFRC10TI OFRC10, OFRC15, OFRC20, OFRC25 OFRC10TI, OFRC15TI, OFRC20TI & OFRC25TI THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE As with all portable heating appliances - This product is only suitable for well insulated spaces or occasional use...
  • Page 2: All Models

    Thermostat Neon ALL MODELS On/Off Heat Switches ALL TI MODELS ONLY 24 Hr Timer Cable wrap ALL MODELS 5 Fin 7/9/11 Fin OFRC10/OFRC10TI OFRC15/OFRC15TI On/Off Table 1 OFRC20/OFRC20TI MANUAL ON 13 : 17 AUTO ADVANCE OFRC25/OFRC25TI...
  • Page 3: Important Safety Advice

    Dimplex Dry Column Heater IMPORTANT: If the mains lead of this appliance Model Description Watts is damaged, it must be replaced by the OFRC10(Ti) Fin, Thermostat, 2 Heat Settings, Neon, (Electronic Timer) 1000 manufacturer or its service agent or a similarly...
  • Page 4: Operation

    Electrical Operation WARNING – THIS APPLIANCE MUST BE EARTHED IMPORTANT – Objects or clothing must not be placed on this heater. Before using the heater ensure that all warnings If the socket outlets in your home are not of the 13 amp and instructions have been read carefully.
  • Page 5 Heat Selector Switches (see Fig. 5) Selector switches located on the control panel provide a choice of heat output to suit varying conditions and for economy of operation. Model Switch Switch OFRC10(TI) 700W 1000W OFRC15(Ti) 1000W 1500W OFRC20(Ti) 1400W 2000W OFRC25(Ti) 1700W 2500W...
  • Page 6: Initial Operation

    Digital Timer Operation (see Fig. 6) Setting Programmes IMPORTANT: Remember to observe all safety warnings Press the ‘PROGRAM’ key to set the programs. when operating the heater on auto setting, either attended You are now setting the programs starting with P1 ‘ON’. or unattended.
  • Page 7 The Dimplex Guarantee does not cover any of the following: Authority or retailer for recycling advice in your country. Any fault or damage to your Dimplex product due to faulty materials or workmanship occurring outside the [three year] Guarantee Period.