Hide thumbs Also See for AT5800:

Advertisement

Quick Links

AUTOMATIC POOL CLEANER
ABOUT SAFETY
• Before installing the cleaner, review and
understand all warnings and safety information
on inside cover of manual.
ABOUT INSTALLATION
• Please use the convenient, water resistant
Installation Instructions card.
AquaTools
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
© 2003, AquaTools
O
W
N
E
R '
OPERATION, TROUBLESHOOTING & PARTS
S
M
A
N
1873 0795
Model AT5800
About Safety .............................................................2
About Your Pool and Filter System ...........................2
About Installation .....................................................3
About the Cleaner Operation....................................4
About the Cleaner and Accessories...........................6
About Troubleshooting .............................................7
About Disassembly ...................................................8
About Assembly........................................................9
Repair Parts.............................................................10
About Maintenance ................................................11
Warranty.................................................................12
Printed in U.S.A.
U
A
L
INDEX
AT364 (Rev. 5/7/03)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT5800 and is the answer not in the manual?

Questions and answers

Summary of Contents for AquaTools AT5800

  • Page 1: Table Of Contents

    AUTOMATIC POOL CLEANER R ’ 1873 0795 Model AT5800 OPERATION, TROUBLESHOOTING & PARTS INDEX ABOUT SAFETY About Safety .............2 • Before installing the cleaner, review and understand all warnings and safety information About Your Pool and Filter System ......2 on inside cover of manual.
  • Page 2: About Safety

    Please read the following before installing your new automatic pool cleaner! ABOUT SAFETY: This is the safety alert symbol. When you see Hazardous suction. this symbol on your system or in this manual, Can trap and tear look for one of the following signal words and be hair or body parts.
  • Page 3: About Installation

    ABOUT INSTALLATION Please use the convenient, water resistant, “Installation Instructions” card. Step 1: Straighten hose (Figure 1) Remove and uncoil the hose from the carton. Lay it out in the sunlight, flat and straight. Step 2: Check parts (Figure 2) Cleaner, black plastic swivel assembly, white rubber reducer cone, one 20’, one 8’, and one 4’...
  • Page 4: About The Cleaner Operation

    ABOUT THE CLEANER OPERATION: shallow end a few times. Clicking sound This sound is the oscillator moving back and forth in Rotating motion – The cleaner will rise up on one side the oscillator chamber. The best speed for it is about and pivot a few times per minute.
  • Page 5 ABOUT “FINE-TUNING” VACUUM ADJUSTMENTS AND CONNECTIONS: Too much vacuum? Skimmer connection You have too much vacuum if the cleaner climbs up the Some pool owners remove the skimmer basket and pool wall past the water line to the point that the clean- connect the hose directly into the bottom of the skim- er sucks air and the pump loses prime.
  • Page 6: About The Cleaner And Accessories

    If not, the pump the specially designed 8’ extension hose from your will suck air through the regulator and lose prime. This Aquatools dealer (order replacement part No. AT5111). could damage the pump. Use of another manufacturer’s hose will hinder cleaner coverage (this also holds true for the 20’...
  • Page 7: About Troubleshooting

    6. In hot water, the hose may kink. The hose, when old, may have developed leaks (cracks or holes) or may get brittle. Purchase new hose. NOTE: It must be an AquaTools hose for proper operation. Cleaner climbs past water 1.
  • Page 8: About Disassembly

    ABOUT DISASSEMBLY 1. Remove swivel assembly (Figure 13) from the top of Swivel "Click" at the cleaner by turning it 1/4-turn counterclockwise assembly this point and pulling straight up on it. 2. Turn cleaner upside down. Remove 4 screws and remove lower body assembly from shroud.
  • Page 9: About Assembly

    ABOUT ASSEMBLY 1. Put both white seals in the oscillator; hold them in place. 2. Install the oscillator on the long gear shaft. Install the ratchet gear on the shaft so that the teeth engage the ratchet on the oscillator. Install the spring, ratchet drum, pinion gear (large gear first), and cam (gear end first) on the shaft (See Figure 19).
  • Page 10: Repair Parts

    Repair Parts Optional Accessories Vacpole Vacpole Unidapt Unidapt Handle, Handle No. AT5119 No. GW9019 1897 0795 Part Part Description Swivel Assembly AT5112 Bumper AT5802 Bumper Insert Kit (Set of 4) AT5820 Screw Kit (4 short, 2 long) AT5804 Shroud AT5801 Brush Ring AT5805 Oscillator Chamber Cap...
  • Page 11: About Maintenance

    ABOUT MAINTENANCE AND CARE • If necessary to remove oscillator, see "Disassembly", Hazardous suction. Stop pump before Page 8. attempting to clean pool cleaner. • Don’t store the cleaner with the hose connected to the • Keep skimmer basket and pump strainer basket clean cleaner body or with the hose coiled.
  • Page 12: Warranty

    Retain Warranty Certificate (upper portion) in a safe and convenient location for your records. DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation to: ▼ AquaTools, Attn: Warranty Dept., 293 Wright St., Delavan, WI 53115 Warranty Registration Card ■ ■...

Table of Contents