MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop This quick start guide will help you to configure data loggers and generate PDF/Excel/CSV reports of recorded readings from it.
Page 3
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Introduction MSR63 MSR83 MSR84 MSR64 MSR86 MSR83 temperature data logger (-30…+70 ⁰C) MSR63 temperature data logger (-30…+70 ⁰C) MSR84 temperature &...
Connect Data Logger MSR BudgetLine data loggers are available with integrated USB 2.0 A-Type plug. Hence, no additional hardware or cable is required to connect the logger with a PC. Note:The logger will be STOPPED automatically after 10 seconds when connected with a PC. You can also STOP the logger manually by pressing the STOP button continuously for 5 seconds until the Red LED is on.
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Configuring Data Logger Connect the data logger to the PC, open the data logger folder «PDF_LOGGER», double-click on UI4Report and...
Page 6
Check if configuration is completed successfully: MSR BudgetLine loggers with display will continuously indicate current reading only (START | STOP | RUN | OKAY will not be shown on the display). Press «START» button on the data logger once; twice blinking of the green LED will indicate that the configuration is completed successfully.
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop START Data Loggers MSR83, MSR84, MSR86 & AMPERPROOF OBUST NDICATION 2.0 A-T USB C ONNECTION Check the status of the data logger: During recording [RUN] & Stop [STOP] mode, press the START button once to view MIN | MAX | AVERAGE values.
Page 9
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Multi-Function LCD Display Logger Status Waiting to START Logger is STARTED Logger is in recording mode Logger is in STOP mode...
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Precautions for Sender Store the data logger in a cool and dry place. Don’texpose the data logger to direct sunlight and avoid condensation forming inside the unit.
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Precautions for Receiver Identify the box containing the data logger. Note down the time when the logger is removed from the box.
Report Generation MSR BudgetLine data loggers are available with integrated USB 2.0 A-Type plug. Hence, no additional hardware or cable is required to connect the logger with the PC. After stopping, when the logger is connected for the first time to the USB port of the computer, both LEDs (green & red) will start flashing to show the report generation is in process.
MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop Report Analysis Selected report format of recorded data will be automatically opened and saved at your selected location just after clicking «Process Report».
Battery change To change the battery, carefully remove the 4 screws from the back of the MSR BudgetLine data logger. Open the housing and remove the button battery. Do not throw the removed battery in the trash, take it to the nearest battery collection point. Insert a new 3.0 V lithium battery (Panasonic CR2032).
Need help?
Do you have a question about the BudgetLine MSR63 and is the answer not in the manual?