How to Use the Wall Plate Controller..................10 b. Connecting to a Touch Screen Controller (External Controller)..........11 9. Accessory Installation..........................11 10. Mounting the Projector...........................11 11. Cable Management..........................12 12. Setting the Show Position........................13 13. Maintenance and Adjustments.......................14 14. Troubleshooting............................15 SVS 12EX Lift Installation Instructions Page 2 of 16...
Lift's scissors to minimize the vertical height of the equipment in a closed position.). Figure 1. shows the SVS 12EX Series Projector Lift with projector, Accessory #9 Projector Mount (projector not included, Accessory #9 sold separately). Figure 1. SVS 12EX Series Lift 2.
3. SVS 12EX LIFT WARRANTY SVS, Inc. 's limited warranty only covers failures due to defects in materials or workmanship that occur during normal use. This limited warranty DOES NOT cover failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper installation and set-up adjustments, improper maintenance or alteration.
Do not remove the lift's shipping blocks until instructed to do so in Section 7. SVS scissor lifts are shipped in a slightly open position to eliminate stress on the limit switches and to maintain a tight cable pack on the cable drum. If physical height measurements are taken before the blocks are removed from the Lift, they may not accurately reflect the height of the closed Lift.
Consider if the lens is offset from the center of the projector and thus the center of the Lift. Figure 2. SVS 12EX Front & Side Views 6. LIFT SUPPORTING STRUCTURE The SVS 12EX Lift should be mounted from six 1/2” rods. The mounting hole locations are marked with a <M> in Figure 3. The thread rods must be supported by a rigid structure.
Figure 6 Recommended Lift Support Structure for Flat Ceilings. This allows for front-to-back and side-to-side adjustments of the Lift for alignment to the screen. Figure 5a. Recommended Lift Support Structure for Flat Ceilings SVS 12EX Lift Installation Instructions Page 7 of 16...
Figure 5b. Recommended Lift Support for Beam Ceilings Important When attaching the Lift to a flat concrete ceiling, SVS suggest two (2) pieces of P1000T Unistrut (or equivalent) approx. 10-feet (3.04 m) long, to be installed on the ceiling first. Proper spacing between the two pieces will be based on the distance between the four (4) mounting holes of the Lift as shown in Figure 4.
8. ELECTRICAL CONNECTIONS Electrical connections should be made at this time. The SVS 12EX Lift requires 110V/60Hz at 2.3 Amps and is supplied with a six foot power cord. The SVS 12EX Lift is controlled with a 24VAC Low Voltage Controller called the Wall Plate Controller.
Lift is secure. WALL PLATE CONTROLLER VIEW FROM BACK RP2 (CONNECTS TO RJ2) SHOW-OFF-SERVICE (SERVICE) (24vac) (SHOW) DOWN MO TOR POWER ON Figure 8. Wall Plate Controller Wiring Diagram SVS 12EX Lift Installation Instructions Page 10 of 16...
3. Program an exclusive lockout on up and down so that both cannot be activated at the same time. (Note: SVS Lifts have a lockout function that disables the Lift when it receives a up and down command at the same time.
Figure 11. Dual Accessory #7 Cable Retractor are standard equipment on all SVS 12EX Series Lifts. The Cable Retractors are a spring-loaded reel on the rear of the Lift. The retractor automatically retracts your cable as the Lift ascends and releases your cable as the Lift descends.
Figure 12. Show Position Adjust Show position and press the toggle switch down. The Lift will lower and stop at the Show position SVS 12EX Lift Installation Instructions Page 13 of 16...
Here are a few common and simple things to check. If at anytime you are unsure of the check, please contact SVS, we will be happy to help you troubleshoot your problem.
Page 16
Turn contacts the Lift will go into a Lock off the external controller when Out. using the wall Plate Controller SVS 12EX Lift Installation Instructions Page 16 of 16...