Raritan PURASAN EX Hold n' Treat Operation, Maintenance, And Installation Instructions

Raritan PURASAN EX Hold n' Treat Operation, Maintenance, And Installation Instructions

Advertisement

Quick Links

PURASAN
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
(Models PST*EX [*specify 12,24] Manufactured after December 2013)
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product.
Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering
Company, Inc. accepts no responsibility or liability for damage to equipment, or injury or death to personnel
that may result from improper installation or operation of this product.
WARNING: HAZARD OF SHOCK AND FIRE
Always use recommended fuse or circuit breaker and wire size.
WARNING: HAZARD OF FLOODING - When leaving the boat unattended always be sure seacocks are closed. Any
installation made below waterline should have double hose clamps securing lines. The halogen disinfectant
is corrosive to aluminum, copper and steel. The plumbing system must not include any aluminum,
copper or steel fittings, piping or holding tanks.
IMPORTANT SAFETY INSTRUCTIONS FOR HANDLING PURASAN
WARNING:
PURASAN
with oil, acids, petroleum products, reducing agents or other chlorine compounds such as swimming
pool tablets, is extremely dangerous
Fire or explosion could result. Improper use of this tablet may cause personal injury or property damage.
WARNING:
Tablets may be fatal if swallowed and tablet dust is irritating to the eyes, nose and throat. Keep out of
reach of children and do not allow tablets or solution of tablets to contact skin, eyes or clothing. Handle
and store tablets as per instructions provided with packaging. Contact Raritan if handling instructions
are missing. Store only in sealed original container in well-ventilated area. Read tablet container label
carefully prior to use. It is unsafe and violation of Federal law to use tablets in a manner inconsistent
with its labeling.
The PURASAN
EX is a U. S. Coast Guard Certified Type I Marine Sanitation Device for use on unin-
®
spected vessels 65 feet and under. It must be operated within navigable waters inside the three mile limit
that are not declared Federal No Discharge Zones (NDZ) by the U.S. Environmental Protection Agency
(EPA). Other countries - check with local authorities.
The PURASAN
EX is designed for recreational use and accommodates most marine toilets. The
®
PURASAN
EX is available in 12 or 24 VDC.
®
DESCRIPTION:
Each time the transfer pump cycles an equal amount of previously treated waste is discharged. The pump-
ing action of the transfer pump moves the waste through the PURASAN
Water is diverted to the Tablet Dispenser during the treatment cycle, creating a halogen solution during hold
time. After the hold time, the Drain Manifold and Air Pump turn on and the solution drains into the Treat-
ment Unit.The first chamber macerates to reduce particle size and uniformly mix the waste with injected
halogen solution. The second chamber mixes to ensure uniform treatment of its contents.
The Hold n' Treat is designed to integrate both a Type I and Type III MSD (Marine Sanitation Device) to
provide the user with a system that will be legal in all areas.
All waste is stored in a holding tank and the treatment mode will determine how the waste is processed.
This system eliminates the need for pump-out stations in most areas.
L519 _0919jlc
®
EX disinfecting tablets are a strong oxidizing agent and highly corrosive. Use or contact
®
EX Hold n' Treat
1
TABLETS AND SOLUTION
®
EX and out.
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PURASAN EX Hold n' Treat and is the answer not in the manual?

Questions and answers

Summary of Contents for Raritan PURASAN EX Hold n' Treat

  • Page 1 FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, or injury or death to personnel that may result from improper installation or operation of this product.
  • Page 2: Switch Panel

    TREAT/NO DISCHARGE MODE; FIG 2 SWITCH PANEL Press no discharge button on panel once to toggle mode from treat to no discharge. Manual Start/Stop If position sensing shutoff valve is installed Disabled for no discharge mode close valve to set no discharge mode Press to switch between Open Valve and press treat/no discharge button on Treat and No Discharge...
  • Page 3: Maintenance

    ® DO NOT add any other chemicals or cleaning products to the FIG 4 toilet or the treatment system. Raritan C.P. (part # 1PCP22) - REFILLING TABLETS Cleans Potties is the only factory-recognized cleaning product that may be used in the toilet.
  • Page 4 WINTERIZATION IMPORTANT: Recommissioning Improper winter lay up is a major cause of failure. IMPORTANT: WARNING: • Do not open shut-off valve feeding control module Do not use anti-freeze of any kind to winterize until Treatment Tank is full. the PURASAN EX system. •...
  • Page 5 U.S.C.G. Type I MSD Certification #159.015/0010133/0 (12V) 159.015/0010134/0 (24V) Maximum Roll/Pitch Angle: 30° Maximum Temperature Exposure: 120° F (49° C) Maximum Total Flush Volume: 1.5 gallons/flush (5.7 liters/flush) Water - fresh, salt or brackish Approximate Number of cycles per tablet--50 Hold n Treat capacity: 6 gallons (23 liters) per hour , 140 Gallon( 530 Liters) per day NOTES: for Wiring Distances are from source to unit and back to source...
  • Page 6 Parts Included in the Box: Inside the module: 6’ black and red Drain Manifold wire to connect Control Module Water Valve 6’ black and orange transfer pump SPC control box wire to connect tank SensaLevel sensor with cable Air Pump 16’...
  • Page 7: Location And Mounting

    LOCATION AND MOUNTING FIG 5 Crossover Plug Treatment Unit: DISCHARGE WARNING: Do not locate in an area where ambient temperature exceeds 120 F (49 INTAKE Locate top of treatment tank at or below 7” discharge of toilet and within six feet (1.5 m) 14 1/8”...
  • Page 8 C. Treatment Unit: PLUMBING NOTE: Use PTFE tape or nonpermanent thread WARNING: HAZARD OF FLOODING sealing compound on threaded PVC fittings and • Installations at or below waterline, at greatest connections. Avoid low areas in hose that would angle of heel, MUST have a VENTED LOOP allow untreated waste to collect.
  • Page 9 3. Run supply wire from source POS to Positive start blinking. If LED’s do not start blinking, (POS) terminal on control module, Install rubber check wiring or contact Raritan technical sup- boot on terminal. port. 4. Run supply wire from source NEG to Negative 5.
  • Page 10 FOR WIRE SIZE BLACK CIRCUIT PURASAN BREAKER/FUSE TREATMENT TANK MANUAL BLACK 12AWG RED 12AWG BATTERY CONTROL MODULE PURASAN EX RARITAN WALL SWITCH PANEL SensaLevel BLACK/WHITE OR RED BLACK CABLE 18AWG 2 CONDUCTOR BLACK FUSE 25 AMP 12V 15 AMP 24V...
  • Page 11 INITIAL SETTING OF “FILL” and “EMPTY” After hold time, air pump and drain valve will drain solution. Make sure that water is drained from entire Must be completed during installation to be sure water tube up to treatment tank. Increase empty time using reaches level mark on dispenser.
  • Page 12 PURASAN EX EXPLODED VIEW SPC** 162000WA (12V) 162000WA 162100WA (24V) 41-137W 42-137W (12V) 43-137W (24V) L518 0919 jlc...
  • Page 13 PURASAN PARTS LIST Item Part # Description TABLET DISPENSER 41-100AW 32-102AW Mixer Motor 2 1/2” Dia. 12 V DC 41-130A Dispenser Body. 33-102AW Mixer Motor 2 1/2” Dia. 24 VDC 41-177 Adapter 1/2”NPT x 1/2” barb (1) includes shaft seals and bushing for mixer motor) 41-153 Dispenser Basket 41-135A...
  • Page 14 Fig13 DRAIN MANIFOLD PORTS Water in Fill FILL CYCLE HOLD CYCLE Empty EMPTY CYCLE To tank Air in Air to disp CHECK VALVE SYMBOL TIME SEQUENCE Note: Fill time and Empty times are programmable. Total treatment time is 120 seconds Drain Solenoid Water Cycle sequence...
  • Page 15: Troubleshooting

    TROUBLESHOOTING WARNING: After the Tablet Dispenser has had water added, it contains a very strong halogen solu- tion. Always wear protective gloves and ventilate well to work on tablet dispenser. Before doing any maintenance or repairs, follow WINTERIZING/STORAGE procedures . CAUTION: Tablet Dispenser may be under pressure.
  • Page 16: Limited Warranty

    EXCLUSION MAY NOT APPLY TO YOU. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or to assume any other liability on behalf of Raritan in connection with its products except as specifically set forth in this warranty.

This manual is also suitable for:

21srp1512