CAUTION!
Do not drill or solder the wire
ends. This is strictly forbidden!
One phase connection — 230 V~
8.3 Assembly
B
< 20 mm
A
12 mm
28 mm
38 mm
230V~
N
L
Green — yellow
N
Blue and gray
L
Black and brown
min.
500mm
A
min. 500 mm
B
57 mm
41 mm
31 mm
Two phase connection — 400 V 2 ~
Green — yellow
Blue and gray
Black
Brown
min.
50mm
min.
2mm
min. 2 mm
> 20 mm
min
30 mm
A
12 mm
28 mm
38 mm
WARNING!
Do not connect the cable with-
out cable end sleeve.
400V 2~N
N
L1
L2
N
A
B
min. 500 mm
B
57 mm
41 mm
31 mm
N
L1
L2
min. 2 mm