ABB HT599017 Operation Manual page 70

Table of Contents

Advertisement

Operation Manual / A150-M56/66/57/67 - A155-M..
7 Periodic maintenance work / 7.4 Cleaning components mechanically
Cleaning the absorption segments
(see Fig. 31: Cleaning the filter silencer →67)
Loosen the tension bands (81270).
u
Remove the cover grid (81266).
u
Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
u
ments (81136).
Clean the absorption segments (81136).
u
When cleaning, note that the absorption segments (81136) must only be cleaned lightly
with compressed air, a soft brush or a moist cleaning cloth.
Have any heavily contaminated absorption segments replaced by an ABB Turbocharging
u
Service Station.
Fitting the filter silencer
(see Fig. 31: Cleaning the filter silencer →67)
Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u
Bend the sheet-metal coverings (81137) back to their original shape and insert into the
u
slotted guides in the filter silencer body (81135).
Fit the cover grid (81266).
u
Fit the tension bands (81270) and tighten them at the locks (81271).
u
Any tension bands that have become damaged must be replaced.
u
Fit the filter ring (81265), if present.
u
© Copyright 2021 ABB. All rights reserved.
HZTL4032_EN
Rev.Q
January 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

A155-m57

Table of Contents