B5. LED blinks seven times, then repeats (IPM Fault: A & E Inverters)
Protection Logic
Blink
Blink
Blink
Blink Blink Blink Blink OFF
- Purpose: Prevent high current due to IPM Short
- Cause: Damaged IPM (Dead Short)
- Test for a dead short at Point A with a VOM.
- Logic: Compressor is forced off and tries to restart in 20 seconds.
Protection
A
Blink 7 times
logic
(Lock Piston Trip) Check B5
Check B
Y
Check IPM
Short
N
Compressor
Replace
visual inspection
Test
Doesn't work
Drive PCB
(turn off)
Point A
Y
Modify
N
Repeat
Check Procedure
Compressor
Y
Power
Damage
Reset
Check C3
NG
Replace
Compressor
- 72 -