  • Page 1 Electromechanical Tripod Turnstile with Automatic Anti-Panic Arms TTR-08 Assembly and Operation Manual...
  • Page 2: Table Of Contents

    CONTENT APPLICATION......................3 OPERATION CONDITIONS..................3 TECHNICAL SPECIFICATIONS .................4 DELIVERY SET......................5 Standard delivery set ..................5 Optional equipment supplied on request............5 BRIEF DESCRIPTION ....................6 Main features .....................6 Design........................6 Control devices of the turnstile................9 Input and output signals and their parameters when operating the turnstile ..10 Control modes of the turnstile ................12 Operation with the RC panel ................12 Operation with the WRC ..................13...
  • Page 3: Application

    TTR-08 Electromechanical Tripod Turnstile Dear Customer, Thank you for purchasing the TTR-08 turnstile. Please follow the instructions given in the Manual carefully, and this quality product will provide many years of trouble-free use. Assembly and Operation Manual (hereinafter Manual) TTR-08 electromechanical tripod turnstile with automatic anti-panic folding arms contains data that is necessary for the fullest use of operating advantages of the turnstile as well as chapters on packaging, installation and maintenance.
  • Page 4: Technical Specifications

    Assembly & Operation Manual 3 TECHNICAL SPECIFICATIONS Operating voltage ................... 121.2 V DC Consumption current ....................max. 6A Power consumption .................... max. 72 W Throughput rate in the free passage mode ..........60 persons/min Throughput rate in the single passage mode ..........30 persons/min Passage width ......................
  • Page 5: Delivery Set

    ID GATE 6000 Electromechanical Tripod Turnstile 4 DELIVERY SET 4.1 Standard delivery set Basic equipment: Turnstile housing ......................1 Hub with barrier arms and fastening ................1 RC panel with cable ...................... 1 Allen key SW3 to remove the cover to the turnstile ............1 Installation tools: Plug ..........................
  • Page 6: Brief Description

    Assembly & Operation Manual 5 BRIEF DESCRIPTION 5.1 Main features • The turnstile is designed either for indoor application or outdoor (see Clause 2). Turnstile housing is produced from high quality stainless steel with ABS plastic covers. • The turnstile plastic side covers are radio transparent that allows concealed mounting of the ACS readers inside the turnstile housing.
  • Page 7 ID GATE 6000 Electromechanical Tripod Turnstile Figure 2. Turnstile components 1 – turnstile housing; 2 – cover; 3 – barrier arm; 4 – LED indication, dynamic; 5 – hub; 6 – hub fastening bolts; 7 – LED indication, side; 8 – AC power cable ;...
  • Page 8 Assembly & Operation Manual Figure 3. RC panel overall view 1, 2, 3 – buttons LEFT, RIGHT, STOP for setting the passage mode; 4, 5 – green indicators «Left», «Right»; 6 – red indicator «Stop», 7 – RC cable. The RC panel / WRC / ACS controller (13), emergency unblocking device Fire Alarm (10), remote LED indicators, control mechanism and the turnstile power supply unit (9) are connected to the CLB with the cables in accordance with the connection layout (see Fig.
  • Page 9: Control Devices Of The Turnstile

    ID GATE 6000 Electromechanical Tripod Turnstile Figure 4. Control Logic Board (CLB) The CLB (Fig. 4) includes: • X1 (LED), X2 (SENS), X3 (MOTOR) connectors to connect the indication module, optical arm rotation sensors and control mechanism with a locking device (from the X1, X2, X3 connectors with the turnstile cable);...
  • Page 10: Input And Output Signals And Their Parameters When Operating The Turnstile

    Assembly & Operation Manual Note: At the parallel connection of the above devices to the turnstile the superposition of the control signals from them may occur. In that case the turnstile response will conform to response to the obtained combination of input signals. (App. 1 and 2). Connection of the devices is made in accordance with the connection layout (Fig.
  • Page 11 ID GATE 6000 Electromechanical Tripod Turnstile Figure 5. ACS control element — normally open relay contact Figure 6. ACS control element — circuit with open-collector output The relays PASS A (contacts PASS A and Common), PASS B (contacts PASS B and Common), Ready (contacts Ready and Common), Detector (contacts Det Out and Common) and Alarm (contacts Alarm 1 and Alarm 2) have normally open contacts.
  • Page 12: Control Modes Of The Turnstile

    Assembly & Operation Manual 5.5 Control modes of the turnstile There are two modes of the turnstile control - a pulse control mode and a potential control mode. They determine available operating modes of the turnstile (Tables 3 and 4). The control mode is set by the jumper on the J1 connector (the J1 connector location is shown on Fig.
  • Page 13: Operation With The Wrc

    ID GATE 6000 Electromechanical Tripod Turnstile Operation logic of the turnstile at the single passage in the A(B) direction at the pulse control mode: 1. When the button, corresponding to the A (B) passage direction, is pressed on the RC panel, the closing of the contact “Unlock A(B)” to the contact “GND” occurs (i.e. forming of the low-level signal on the contact “Unlock A(B)”...
  • Page 14: Additional Devices Connectable To The Turnstile

    Assembly & Operation Manual 5.9 Additional devices connectable to the turnstile The following external devices can be connected to the turnstile: • intrusion detector; • siren; • emergency unblocking device “Fire Alarm” (10); • remote indicators. The intrusion detector is connected to the XT1.L, connector block, and the siren is connected to the XT1.H connector block of the CLB according to the connection layout (Fig.
  • Page 15: Emergency Unblocking Of The Turnstile

    ID GATE 6000 Electromechanical Tripod Turnstile Figure 8. Output cascades for Light A and Light B 5.10 Emergency unblocking of the turnstile Emergency unblocking of the turnstile is performed by input of the “Fire Alarm” signal to the turnstile. At that the barrier arm automatically falls down ensuring free passage. Green indication with momentary changing into red will be activated on the side LED indication and dynamic LED indication.
  • Page 16: Marking And Packaging

    Assembly & Operation Manual 6 MARKING AND PACKAGING The turnstile has the marking on the turnstile housing in the form of a label located on the inner panel of the turnstile housing. The label contains manufacturer’s trademark and contact details, year and month of production, operating voltage and power consumption of the turnstile.
  • Page 17: Installation Instructions

    ID GATE 6000 Electromechanical Tripod Turnstile 8 INSTALLATION INSTRUCTIONS Follow the safety requirements during the installation (see Clause 7.1) 8.1 Installation details Correct turnstile installation provides its functionality and lifetime. Please carefully study and follow the installation instructions. It is recommended: •...
  • Page 18: Length Of Cables

    Assembly & Operation Manual • Horn-type and socket wrenches: S17, S13 and S10; • Set square 90º; • Allen key S3; • Level; • Measuring tape (2 m); • Hard wire 1.5 m long for cable pulling; • Slide caliper. Note: It is allowed to use other testing equipment and measuring tools provided the equipment in use ensures the required parameters and measurement accuracy.
  • Page 19 ID GATE 6000 Electromechanical Tripod Turnstile Figure 10. Floor anchor position and cable entries for housing installation (turnstile housing is dotted) Figure 11. Turnstile with cover removed 1 – reinforcement plate; 2 – fixing screws of reinforcement plate; 3 – turnstile housing; 4 – back panel; 5 – readers installation place 8.
  • Page 20 Run a test switch on of the turnstile as specified in clause 9.1 «Power-up». IDTRONIC produces IP-based entrance control systems KT-08.3A with similar design which has got built-in ACS controller and built-in card-readers. Their read range is at least 6 cm from...
  • Page 22 Assembly & Operation Manual Figure 13. Turnstile cover connection layout Table 2. Connection layout description Legend Name Q-ty Note Control mechanism Turnstile cover A3, A4 Indication blocks, side (IB1, IB2) For IM1 – jumper in position L, A3.1, A4.1 Indication modules (IM1, IM2) for IM2 –...
  • Page 23: Operation Instructions

    ID GATE 6000 Electromechanical Tripod Turnstile 9 OPERATION INSTRUCTIONS Follow the turnstile operation safety requirements (see Clause 7.2 «Operation safety requirements». It is prohibited! • To move through the turnstile passage area any objects with dimensions exceeding the width of the passageway. •...
  • Page 24 Assembly & Operation Manual Table 3. Pulse control mode (the jumper is set on the J1 connector) Indication The turnstile Actions operating Turnstile status on the RC to do on the LED display modes panel The “Red cross” for Always locked Press the STOP The red indicator each passage...
  • Page 25: Operating Modes Of The Turnstile At Potential Control Mode

    ID GATE 6000 Electromechanical Tripod Turnstile Note: Pressing the button on the RC panel corresponds to the low-level signal supply to the contacts (“Unlock A”, “Unlock B” and “Stop”) of the XT1.L connector block relatively to the contact “GND”. 9.3 Operating modes of the turnstile at potential control mode See Table 4 for the operating modes set from the RC panel.
  • Page 26: Troubleshooting

    Assembly & Operation Manual 9.5 Troubleshooting Possible faults, which can be cleared by the users themselves, are listed in Table 5. Table 5. Possible faults and remedy POSSIBLE FAULT REMEDY CAUSE Switch off the turnstile power supply from the At the power-up the turnstile No supply AC mains, open the turnstile housing cover.
  • Page 27: Maintenance

    ID GATE 6000 Electromechanical Tripod Turnstile 10 MAINTENANCE The turnstile housing maintenance is required once a year or in case of some technical failures. The maintenance should be carried out by qualified mechanic only. Caution! Prior to the turnstile maintenance works disconnect the turnstile power supply from the AC mains.
  • Page 28: Transportation And Storage

    (15) with S17 socket wrench. Before it is necessary to remove plastic plugs (16) out of the holes in the turnstile housing base. In case of any defects revealed during visual check please apply to the IDTRONIC Technical Support Department (the IDTRONIC TSD).
  • Page 29: Appendix 1. Control Signal Algorithm At Pulse Control Mode

    ID GATE 6000 Electromechanical Tripod Turnstile APPENDIX 1. Control signal algorithm at pulse control mode Note: For the RC panel: • active front — pressing of the relevant button on the RC panel; • low level— the relevant button on the RC panel has been pressed; •...
  • Page 30 Assembly & Operation Manual Free passage in the direction B (open for free passage in the direction B) Active front is at the contact “Unlock B” while there is a low level at the contact “Stop” and a high level at the contact “Unlock A”, or active front is at the contact “Stop”...
  • Page 31: Appendix 2. Control Signal Algorithm At Potential Control Mode

    ID GATE 6000 Electromechanical Tripod Turnstile APPENDIX 2. Control signal algorithm at potential control mode Note: For an ACS controller outputs: • low level — either contacts of the output relay are closed or the output transistor is open. • high level — either contacts of the output relay are broken or the output transistor is closed.