Form The Pipe - LG LP-X809FE0 Installation Manual

Floor standing type
Table of Contents

Advertisement

Installation of Unit
Form the Piping
1. Wrap the connecting portion of indoor unit
with the insulation material and secure it with
two Plastic Bands. (for the right piping)
• If you connect an additional drain hose,
the end of the drain-outlet should be kept
distance from the ground. (Do not dip it
into water, and fix it on the wall to avoid
swinging in the wind.)
In case of the outdoor unit is installed below
position of the indoor unit.
2. Tape the Piping, and Connecting Cable from
down to up.
3. Form the piping gathered by taping along the
exterior wall and fix it onto the wall by saddle
or equivalent.
In case of the outdoor unit is installed upper
position of the indoor unit.
1. Tape the piping and connecting cable from
down to up.
2. In order to prevent water from entering the
room, form a trap and tape the piping.
3. Fix the piping onto the wall with saddle or
bracket.
18 Floor Standing type Air Conditioner
Main cable
Gas side piping
Connecting Cable
(For heater)
Connecting Cable
Trap is required to prevent the electrical parts
from entering the water.
Seal a small opening around
the piping with gum type sealer.
Tube PE
Foam
Trap
Trap