Heat pump technology and refrigerant:
this tumble dryer uses a gaseous refrigerant which is condensed by
the compressor. The refrigerant, which is brought to a higher temper-
ature level and liquefied by condensing, is led in a closed circuit
through the heat exchanger unit where heat exchange with the circu-
lating drying air takes place.
 Damage to the tumble dryer by switching it on too soon.
This can damage the heat pump.
After setting up the tumble dryer wait for at least one hour before
switching it on.
– The humming noises caused by the heat pump during the drying
process are normal. They do not impair the efficient functioning of
the dryer.
– The refrigerant is not flammable or explosive.
– This tumble dryer contains fluorinated greenhouse gases. Her-
metically sealed.
Designation of refrigerant
Refrigerant quantity
Ozone-depletion potential of
refrigerant
Ozone-depletion potential of
appliance
The designation and quantity of refrigerant that apply to this tumble dryer, and
the ozone-depletion potential, can be found on the data plate (at the back of the
tumble dryer).
10
R134a
R134a
0.48 kg
0.30 kg
1430 kg CO
e 1430 kg CO
2
686 kg CO
e
429 kg CO
2
R450A
0.31 kg
e 605 kg CO
2
2
e
188 kg CO
2
2
e
e