Dismantling Insulation, Gas Inlet Casing And Nozzle Ring (A175-L And Smaller) - ABB A175-L35 Operation Manual

Hide thumbs Also See for A175-L35:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
8
Disassembly and assembly
8.8
Dismantling insulation, gas inlet casing and nozzle
ring (A175-L and smaller)
Dismantling the insulation
Dry cleaning
The dry cleaning does not have to be removed to dismantle the insulation.
NOTICE
Figure 37: Removing the insulation (A175-L and smaller).
1. Loosen and remove screws of insulation jackets (51200) from gas outlet casing (61001).
2. Loosen and remove all connecting plates of insulation jackets.
3. Remove insulation jackets.
4. Detach flange connection between gas inlet casing (51001) and bellows.
© Copyright 2016 ABB. All rights reserved.
HZTL4034_EN
Page 72 / 113
Revision H
November 2016