Dynamo Power DPX7500 Owner's Manual

Dynamo Power DPX7500 Owner's Manual

Diesel generator

Advertisement

Quick Links

DYNAMO
---:::::::a
Diesel Generator
1
Owner
DPX7500
customerservice@dynamopower.net or 1-888-914-2210
Monday
-
Friday 9am
-
3pm EST
productsupport@dynamopower.net or 1·888-914-2210
Monday - Friday 9am - 3pm EST
This manual provides information regarding the. operation and maintenance of
We have made every effort to ensure tile accuracy of tl'le Information In this mMoal.
We
the right
change this product at any timl' without prior notice.
reserve
to
POVVf=:R
s Manual
these
produc.t:S.
DANGER
CARBON MONOXIDE
Using a generator indoors WILL KILL YOU IN MINUTES!!
Generator exhaust contains high levels of carbon monoxide
(CO), a poisonous gas you cannot see or smell. If you can smell
the exhaust, you could be breathing CO.
• NEVER use a generator inside homes, garages, crawl
spaces or other partly enclosed areas. Deadly levels of
carbon monoxide can build up in these areas. Using a fan
or opening windows and doors does NOT supply enough
fresh air.
• ONLY use a generator outdoors and far away from open
windows, doors and vents. These openings can pull in
generator exhaust.
• Even when you use a generator correctly, CO may leak into
the home. ALWAYS use a battery-powered or battery­
backup CO alarm in the home.
• If you start to feel sick, dizzy or weak after the generator
has been running, move to fresh air RIGHT AWAY. See a
doctor. You could have carbon monoxide poisoning.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPX7500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynamo Power DPX7500

  • Page 1 Using a fan Owner s Manual or opening windows and doors does NOT supply enough DPX7500 fresh air. • ONLY use a generator outdoors and far away from open windows, doors and vents. These openings can pull in generator exhaust.
  • Page 2: Table Of Contents

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR CHAPTER 1. TECHNICAL SPECIFICATIONS AND DATA TABLE OF CONTENTS 1-1 Technical specifications and data Page number CHANGFA Single-cylinder diesel generator Chapter 1 Technical Specifications and Data 1-1 Technical specifications and data Rated frequency (Hz)
  • Page 3: Basic Operating Instructions

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 1-2 Basic operating instructions C: recoil starter C: recoil starter Starter system 1-2.1 Under the given conditions, the generator will output the specified power in the table E: recoil starter/electric E: recoil starter/electric starter listed below.
  • Page 4: Chapter 2 Operating The Diesel Generator

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR CHAPTER 2 OPERATING THE DIESEL GENERATOR Note: When connecting devices to the generator, make sure all other devices are rated lower than the generators output. Any generator socket should not be 2-1 General main points of safety during operation of the generator set.
  • Page 5: Preparation Before Operation

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 2-2 Preparation before operation 2-2.2 Filling engine oil 2-2.1 Fuel choices and fuel treatment Remove the dipstick from the engine Fuel tank Make sure the generator is on level ground, and fill the engine with 15W40 engine oil.
  • Page 6: Checking The Operation Of The Diesel Engine

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 2-2.3 Checking the air filter 2-3.3 Engine break in (1) Loosen the butterfly nut, take the cover of the air When you purchase a brand new engine, the engine must be properly broken filter off and take the air filter element out.
  • Page 7: Procedures For Starting The Generator

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR The electromagnetic iron will be triggered, now turn it clockwise to the “START” 2-5 Procedures for starting the generator position. This procedure applies to the CF series recoil starting style models. 4. After the diesel engine is started, remove your hand from the switch handle; the switch will automatically reset itself to the “ON”...
  • Page 8: Proper Operation Of The Generator

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 2-6 Proper operation of the generator 2-6.1 Operating the diesel engine 1. Pre-heat the diesel engine for 3 minutes under no load conditions. 2. First check the height of the lubricating oil level, if it is low, refill it.
  • Page 9: Stopping The Generator

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR Connect the large loads onto the generator first. If everything is functional, smaller loads can then 2-8 Stopping the generator be added. If the generator shuts off, it may be because the load being drawn by all the various devices are too high.
  • Page 10: Chapter 3 Maintenance

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 3-1.1 Changing the engine oil (every 200 hours) CHAPTER 3 MAINTENANCE 3-1 Maintenance schedules Keeping your generator well maintained will prolong the life of your generator. Everything needs to be Take the oil cover off. Remove the oil checked including the diesel engine, generator, control cabinet, and frame.
  • Page 11: Storing For A Long Period Of Time

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR 4-1 Questions and doubts 3-1.5 Battery check If you do not understand anything or have any questions, please feel free to Make sure the battery acid is full. The engine uses a 12V battery. Due to contact your local dealer or with our company directly.
  • Page 12: Chapter 5 Generator Parts Diagrams And Listings

    DPX7500 DIESEL GENERATOR DPX7500 DIESEL GENERATOR CHAPTER 5 GENERATOR PARTS DIAGRAMS AND LISTINGS...

Table of Contents