Reviewing The Front Buttons And Display - Omega Engineering PAX-1/8 Manual

Din preset timer (paxtm) & real-time clock (paxck)
Table of Contents

Advertisement

4.6 REAL-TIME CLOCK WIRING (PAXCK)
Time
synchronization
between
PAXCK meters can be accomplished through a
hardware interface on the Real-Time Clock option
card. This RS485 type interface allows connection
of up to 32 PAXCK meters in a two-wire
multidrop network, at distances up to 4000 ft.
In a synchronization network, one PAXCK
meter is programmed as the Host, while all other
meters are programmed as Slaves. Once every
hour,
the
Host
meter
outputs
synchronization pulse onto the network. Upon
receiving the synchronization pulse, each Slave
meter automatically adjusts the minutes and
seconds of its RTC Time setting to synchronize
with the Host.
5.0 R
EVIEWING THE
KEY
DISPLAY MODE OPERATION
DSP
Index display through Timer, Cycle Counter, Date, and Time
PAR
Access Programming Mode
V V
F1
Function key 1; hold for 3 seconds for Second Function 1 **
W W
F2
Function key 2; hold for 3 seconds for Second Function 2 **
RST
Reset (Function key) ***
* Cycle counter and Real-Time Clock displays are locked out in Factory Settings.
** Factory setting for the F1 and F2 keys is NO mode.
*** Factory setting for the RST key is
multiple
a
time
F
RONT
ES4U &
(Reset Display)
Real-Time Clock Synchronization Figure
B
UTTONS AND
PROGRAMMING MODE OPERATION
Exit programming and return to Display Mode
Store selected parameter and index to next parameter
Increment selected parameter value or selections
Decrement selected parameter value or selections
Selects digit location in parameter values
9