SMBS-T4-PROD-MAN v1 Sigfox Access Station Micro SMBS-T4 Product manual February 2020 ote: Only the last version of this document available on the Sigfox technical system documentation is official and applicable. This document is confidential and is the property of Sigfox. It shall not be copied and / or disclosed to third parties, in any form without...
The Access Stations Micro include a complete system described in the Network overview below. Sigfox Access Station Micro series are ultra-wide range, high linearity transceivers units and feature first class performance radio and innovative software defined radio processing, for use in Ultra Narrow Band Machine-To-Machine wireless communication systems.
3. Package contents • Sigfox Access Station Micro SBMS-T4 • Mounting kits (2 ties and 2 set of screws and anchors) • PoE DC injector • Ethernet cable CAT6 1.5m • Power adaptor 110/220V AC to 24V DC 18W •...
4. Installation recommendation Access Station Micro has been developed for indoor and outdoor operation. For temporary location, the base station is perfectly stable sitting on a table, a desk or a shelf. For permanent installation, we recommend using the mounting kits for long-term fixation.
4.1. Access Station Orientation The table below describes the preferred orientation to maximize the radio performances of the access station: Preference Orientation Illustration order Standing up Upside down Aside 4.2. Access Station Mounting The following table describes the different mounting options offered with the kit...
4.3. Sealing Cover To install the Access station micro outside, or in an environment exposed to high humidity, dust, or even to prevent thief, you must use the sealing cover to protect the connectors and the USB dongle if used. The sealing cover provides an Ingress Protection IP65.
Page 8
• Avoid installation on the last floor in case of cellular BS on the roof and away from windows to reduce RF interferers from cellular/broadcasters” Note: When installed vertically on a wall, the connector must be facing downward.
4.4.2. Outdoor: For outdoor deployment, it is recommended to place the Access Station Micro above, facing and in the periphery of the connected devices for best result.
5. Connection and commissioning 5.1. Interface USB port Ethernet port 5.2. Power supply The station is powered with a passive PoE. The PoE splitter is integrated in the station. The power is conveyed from the AC/DC adapter through the DC injector and the ETH cable (all provided in the box).
Standard installation (24v): Cable length < 40m (without heating, length < 60m) 5.2.3. Power consumption The power consumption depends on the station mode, use of cellular dongle and external temperatures. Typical: 2.3W (RX mode) or 4W (TX mode) with Ethernet connection.
5.3. Connectivity The Access Station Micro needs Internet access to operate. It can be connected via Ethernet cable (RJ45 port on PoE injector) or Cellular USB dongle (USB port on station). When both connections are used to improve link robustness, the Ethernet one is automatically set as primary and Cellular is set as secondary backup.
Access Station Utility application. Access Station Utility in available for download from Google Pay to suitable phones or tablets. https://play.google.com/store/apps/details?id=com.sigfox.accessstation.utility Once installed, connect the device to the Sigfox Access Station Micro (powered) with a USB cable and provide the required information.
5.5. LED status Meaning Troubleshooting Check power supply, injector and Ethernet No power cable (for ≈30 secs) Power on If the light remains red after 2 minutes, try to unplug and plug again the station. If the – Solid (> 1 Hardware issue problem persists, contact your support.
6. Annexes 6.1. Labels 6.1.1. Product ID Model : SMBS-T4 Input : 12V / 5.4A S/N : 00003421 OF number : sigfox 425 rue Jean Rostand 31670 Labège, France www.sigfox.com Designed in France Assembled in Spain GTIN/EAN : 3665306000207 6.1.2.
6.2. Specifications RADIO CHARACTERISTICS Standard Sigfox Ultra Narrow Band Protocol for M2M and IoT Max range of operating frequencies * 865 to 928 MHz Receiver Sensitivity -132dBm @ 100bps / -124dBm @ 600bps Data Rate and Modulation 100 bps D-BPSK (UL) 600 bps GFSK (DL) Max Transmit Power * (EIRP) 23 dBm ±...
Page 17
MECHANICAL AND ENVIRONMENTAL Product weight 450g (1 lb) Operating temperatures -20°C to +55°C Storage temperatures -30°C to +85°C Robustness MTBF 92,000 hours Casing material Plastic ASA/PC Dimensions (in mm): Sealing cover:...