Installation - GE AEC12 Owner's Manual And Installation Instructions

Room air conditioner
Table of Contents

Advertisement

Available languages

Available languages

Installation

Instructions
Questions? Call GE Appliances at 800.GE.CARES (800.432.2737) or Visit our Website at:
GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT
instructions for local inspector's use.
IMPORTANT
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time –
• We recommend that two people install
this product.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
installation procedures as described in these
instructions when installing this air conditioner.
ELECTRICAL REQUIREMENTS
Some models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall outlet
you plan to use is only a 2-prong outlet, it is your
responsibility to have it replaced with a properly
grounded 3-prong wall outlet.
Some models require 230/208-volt AC,
protected with a time-delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
49-7770-1
— Save these
— Observe all
Air Conditioner
CAUTION
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
Do not change the plug on the power cord
of this air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
TOOLS YOU WILL NEED
Phillips-head screwdriver
Flat-blade screwdriver
Pencil
Level
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on a periodic basis
by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of the
air conditioner and contact a qualified service
technician.
Ruler or tape measure
Scissors or knife
7

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Aec10Aed10Aec10awAec12awAed10av

Table of Contents