Black & Decker Price Pfister R89-1TU Manual page 3

Table of Contents

Advertisement

Available languages

Available languages

7
7B
7A
DECREASE
MAXIMUM
TEMPERATURE
INCREASE
MAXIMUM
TEMPERATURE
7D
7A
7B
Adjustment Gear (7A) is factory-set to prevent stem from reaching full hot
position. To determine if factory setting is satisfactory, turn on valve and rotate
Stem (7B) counterclockwise to full hot and test. If not, remove Adjustment Gear
(7A) with valve at full hot setting. To adjust valve to a colder setting, rotate
Stem (7B) clockwise or counterclockwise to a hotter setting (Use a thermometer
for measuring). Price Pfister recommends a maximum temperature setting
of 110°F (43°C). Replace Adjustment Gear (7A) onto Stem (7B) by aligning
the surfaces of Valve Stop (7C) and Adjustment Gear Stop (7D) as shown.
Once placed, Stem (7B) should not rotate any further in the counterclockwise
direction.
Clockwise
Rotation
7B
Counterclockwise
Rotation
7B
7C
ENGLISH
8
8A
8D
8C
8E
8 TRIM FLANGE ATTACHMENT
Position Flange (8A) on Valve (8B) with Drain Hole (8C) at the bottom. Place
Protective Washer (8D) on the short end of the reversible Retainer Sleeve
(8E). Screw Retainer Sleeve (8E) onto threaded section of the Stem and
Bonnet (8G). Tighten Retainer Sleeve (8E) by hand until Flange (8A) is snug
to finished wall surface. If the short end of the Retainer Sleeve (8E) is too
short, reverse it to use the longer end.
9
9B
9A
9C
9 FLOW FUNCTION HANDLE ATTACHMENT
With valve in "CLOSED" position, place and align Handle Hub (9A) onto
Cartridge Gears (9B). Be sure Lever (9C) is facing down. Secure with Set
Screw (9D).
10
10B
10A
3
8G
8C
9D
8B

Advertisement

Table of Contents
loading

Table of Contents