Seebacher ISYGLT I/O-08B-24V-1A Technical Data/Instruction Manual

Seebacher ISYGLT I/O-08B-24V-1A Technical Data/Instruction Manual

8-way switching actuator

Advertisement

Quick Links

Technical Data / Instruction Manual
I/O-08B-24V-1A
Article no. 80021000
8-way Switching Actuator
1
Seebacher GmbH
www.seebacher.de
Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz
info@seebacher.de
Fax: +49 (0) 80 41 / 77 77 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISYGLT I/O-08B-24V-1A and is the answer not in the manual?

Questions and answers

Summary of Contents for Seebacher ISYGLT I/O-08B-24V-1A

  • Page 1 Technical Data / Instruction Manual I/O-08B-24V-1A Article no. 80021000 8-way Switching Actuator Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6 Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2...
  • Page 2: Notes On Documentation

    1.1. Retention of documents use. 1.2. Symbols used SEEBACHER cannot accept any liability for damage or malfunctions resulting from failure to observe these instructions. 2. Safety instructions 1.1. Retention of documents These instructions and all other applicable documents are part 2.1.
  • Page 3: Safety Instructions

    SEEBACHER shall not be liable for any costs or damage incurred by the user or third parties as a result of the use of this 2.3. Safe handling...
  • Page 4: Warranty

    Switch off the power supply, check that there is no voltage, secure against being switched on again! The device may only be operated at voltages according to the tech- Seebacher GmbH nical data and loaded with the currents defined therein. Only use Marktstrasse 57 suitable equipment (system modules).
  • Page 5: Product Description

    Special function DIP switch 1 = Emergency operation • Switch „OFF“ = BUS operation • Switch „ON“ = Emergency operation (8x impulse switching function: input E1 switches output A1, input E2 switches output A2, etc.) Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6 Marktstrasse 57, 83646 Bad Tölz...
  • Page 6: 10. Technical Data

    @ Ub Operating voltage Operating voltage Subnet (BUS A, RS-485) Subnet (BUS B, RS-485) Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6 Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2...
  • Page 7 A1 A2 C.3 A3 A4 C.4 A5 A6 C.5 A7 A8 C.6 ~Ub 0V A A1 A2 C.3 A3 A4 C.4 A5 A6 C.5 A7 A8 C.6 ~Ub 0V A Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6 Marktstrasse 57, 83646 Bad Tölz...
  • Page 8 ISYGLT-I/O-08B-24V Art.-Nr.: 80021000 max. 24V/1A each relay Misprints and technical changes reserved. Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6 Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2...