Page 1
iX3M Dive Computer User Manual ver. 1.14...
Page 2
ATTENTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules . Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 3
Warning! To receive all updates of this manual and notice of future updates of the “iX3M” by e-mail, please send a message writing “iX3M” update@ratio-computers.com to the following address: This service is highly recommended and it is completely free of charge. For further support, have a look at the tutorial videos soon available on www.ratio-computers.com...
Page 4
Warning! This Manual DOES NOT replace an adequate diving training and should be used only by those divers who have been appropriately trained by a certified diver training organization. To completely understand the terminology used in this manual and the functions of the dive computer a proper diving training is required.
Page 5
Think Green If possible do not print this manual. Use your tablet or your PC to consult it . http://www.wwf.it/tu_puoi/vivere_green/ecoconsigli/ecoconsigli_in_ufficio/...
CONTENTS Introduction The RATIO iX3M outside the Water: 23 The main screen 27 The RATIO iX3M Menu 28 MAIN MENU DIVE SET for RATIO iX3M Deep Important Warnings DIVE SET for RATIO iX3M Tech+ & iX3M Reb DIVE SET for RATIO iX3M Tech+ & iX3M Reb 9 General Warnings Deco Stop for RATIO iX3M Tech+ &...
Page 7
CONTENTS The RATIO iX3M when diving 51 Dive Screen Main Data Current dive’s profile: Tissues saturation when diving: Decompression Chart: 56 Compass when diving Applications when diving Mix change during the dive 59 Setting change during the dive Mix change during the dive Change Conservatism during the dive Change the set point during a dive The iX3M in GAUGE mode...
Introduction Thank you for having purchased the RATIO® computer. RATIO®, with the quality of its products, always stands by you to guarantee comfort, leisure and safety when diving. The RATIO® computer that you have purchased is extremely innovative, with a software allowing you to carry out both recreational and technical dives.
Important Warnings General Warnings It is necessary read this manual carefully before using the computer RATIO®. A wrong use of this computer or its accessories will nullify the warranty and could cause permanent damages to the device and/or its accessories. •...
Page 10
• The computer doesn’t replace the learning of the diving decompression charts which we recommend to have always as backup along with a depth gauge and a watch. • Never share a unique computer for two divers while diving; every diver must have his/her device at his/her wrist, which can give information to him/her only.
Danger Warning The computer IS NOT meant for a PROFESSIONAL use. The computer is meant exclusively for a sport, recreational or technical use. • A use which is not compliant to what has been said above, could expose the diver to an increasing risk of incurring in the Decompression Sickness (DCS).
Page 12
• We recommend to do dives within the safety curve, to reduce the risks inherent to the Decompression Sickness (DCS). • We recommend dives not deeper than 40 mt or according to the oxygen percentage contained inside the tank. Maximum PPO2 1,4 BAR •...
Diving with Mix The safety approximation of the Mix has to be decided by the diver. If you are not sure about the EAN safety approximation to be set for your dive, ask your diving instructor or your diving certification agency •...
Limits of diving computers The computer takes into consideration the most updated safety guide lines, nevertheless, it is always necessary to know that such studies are theoretical and elaborated to reduce, not to avoid, the risk of Decompression Sickness (DCS). At the moment, the Hyperbaric Medicine doesn’t allow to eliminate totally the risk of DD.
Page 15
The EC laws require that the unit is checked periodically from the reading precision, depth and time point of view. • Warranty is voided if the computer is opened by a not authorised assistance centre. • The RATIO iX3M computer is designed to be waterproof in sea water but, at the end of every dive, it must be well rinsed in fresh water and it must not be dried exposing it at the direct sun light or at heat sources.
Computer’s technical characteristics Hardware The computer is fully built in POM C with Makrolon cover, allowing an extreme resistance to hits and to corrosion. The screen is provided with a Display TFT 100%; its matrix has 320x240 pixel resolution Particular commitment has been put in developing a navigation system allowing the diver to have an easy and intuitive access to all settings.
Software Algorithm: The computer uses either the Bühlmann ZHL-16B model or the VPM-B model. Every computer can be set up on one algorithm or the other, at the user’s discretion. For RATIO iX3M Deep: Operating on level systems it is possible to set up the conservatism desired. For RATIO iX3M Tech+ and iX3M Reb: Using the Bühlmann ZHL-16B algorithm there is the possibility of an exact choice of the Gradient Factors.
How to recharge the Battery The RATIO iX3M has a Li-Ion rechargeable battery without memory effect, with an autonomy of 20-50 diving hours. The autonomy data which are shown can change of +/- 15% depending on the environmental temperature, the device settings, the installed applications, the operative system version, the back light setting and the use of its inner (GPS - Bluetooth)or external (Analyser) peripheral devices.
Page 20
When connecting the USB cable to recharge the device, the symbol => will appear in the watch screen within 45 seconds. It means that recharging procedure is in progress. When the recharge is finished the symbol => will disappear. Once the battery charge is finished, even if the device remains connected to the plug, the computer automatically interrupts the electricity flow.
Diving in cold or freezing waters The RATIO iX3M can be used even in case of dives in cold or freezing waters (<3°C); however, the exposure at particularly low temperatures, may affect negatively on the battery residual voltage. When diving in cold or freezing waters, the battery voltage may decrease more rapidly than normal. So, we recommend to recharge the battery before diving in extreme conditions.
DAN DL7 The RATIO iX3M is 100% compatible with the program for gathering data DAN DL7 of DSL Level 5 100% compatible with The DAN DL7 is a format owned by DAN, which summarizes all necessary information which are DAN DL7 needed for the studies, arranging them to be sent directly to DAN Europe’s central database.
The RATIO iX3M outside the Water: The main screen To switch the RATIO iX3M on, press any button. The RATIO iX3M switches off automatically after 10 minutes of tatal inactivity. After diving the RATIO iX3M activates the Sleep mode modality: after 10 minutes of inactivity it switches the screen off and deactivates all processes which are not useful for the post-diving de-saturation calculation .
Page 24
First line: In the first line of the introductory screen the RATIO iX3M shows: - Battery indicator (on the top left side) the RATIOiX3M uses a colour code to advise you on its battery status Green colour (100%->50%): Everything is ok Yellow colour (50%->20%): Alert (do not make extremely demanding dives or in cold or freezing waters) Red colour (<20%): Battery almost dead, recharge as soon as possible.
Page 25
Second line: - Atmospheric Pressure expressed in millibar (on the left) The Atmospheric pressure is the one present in any point of the terrestrial atmosphere. It is measured in millibar (mbar) Attention: after diving, owing to the humidity on the sensor’s location, the read pressure might be slightly lower than the real one.
Page 26
Third line: - Barometric alitmeter (on the left) The height above the sea level is calculated on the basis of the barometric pressure. Attention: The altitude detection through the barometer can be affected by the presence of humidity in the sensor area. In case of case of bad weather or after diving, the error might also be of +/-80m.
The RATIO iX3M Menu DIVE MODE MAIN MENU DIVE SET DIL TABLE DECO STOP ALARM CCR SET PLANNER MIX TABLE LOGBOOK COMPASS SYSTEM SET MENU DISPLAY COMPASS GENERAL SET SENSOR BOARD PC MODE INFO DEFAULT SWITCH OFF APP MENU CHRONO MAGMETER MIX ANALYZER PITCH ROLL...
MAIN MENU From the main screen, press button A to have access to the menu. Use buttons A-B-C-D as described in the picture to navigate in the menu. The selected entry is indicated in red. (According to your RATIO iX3M model, some entries might not be visualized.) MAIN MENU Do you know what?: DIVE SET...
DIVE SET for RATIO iX3M Deep For iX3M Deep only To navigate the menu, follow the clues in the picture. To reach this menu from the main screen Algorithm: Select the decompressive algorithm you want to use for your dive. press in sequence: BUL: Bühlmann ZHL-16 B VPM: VPM-B...
DIVE SET for RATIO iX3M Tech+ & iX3M Reb For iX3M Tech+ iX3M Reb To navigate this menu follow the clues in the picture on the left. Algorithm: Select the decompressive algorithm you want to use for your dive. To reach this menu from the main BUL: Bühlmann ZHL-16 B screen press in sequence: VPM: VPM-B (go to the next page)
Page 31
DIVE SET for RATIO iX3M Tech+ & iX3M Reb For iX3M Tech+ iX3M Reb To navigate this menu follow the clues in the picture on the left. To reach this menu from the main Algorithm: Select the decompressive algorithm you want to use for your dive. screen press in sequence: BUL: Bühlmann ZHL-16 B VPM: VPM-B...
Page 32
S. STOP TIME: It sets the Safety Stop’s time in minutes. To reach this menu from the main screen press in sequence: You can set the time from 0 to 9 minutes (if 0 the Safety Stop is omitted) Do you know what?: The different diving agencies can recommend different times for the Safety Stop.
Page 33
WATER: Is set to what type of water you are about to dive in To reach this menu from the main screen press in sequence: (SALT= Sea water, FRESH= lake water) ATTENTION: The dive computers measure the pressure and convert it depth using the water density as constant. Without the SALT/FRESH setting the depth reading might be altered (If you dive in fresh water with WATER=SALT setting the depth detected by the iDive will be lower than the real one, vice versa if you dive in salt water with WATER=FRESH setting the depth detected will be higher than the real one.)
Deco Stop for RATIO iX3M Tech+ & iX3M Reb For iX3M Tech+ iX3M Reb To navigate the menu follow the instructions in the picture on the left. To reach this menu from the main The whole dive profile is divided in 3 depth zones. screen press in sequence: First Zone: from the surface to depth DEPTH1.
CCR Settings for RATIO iX3M Tech+ & iX3M Reb For iX3M Tech+ iX3M Reb To navigate the menu follow the instructions in the picture on the left. To reach this menu from the main CCR MODE: ON= CCR enabled in scuba mode. /// OFF= Deactivated. screen press in sequence: SETPOINT LOW: Range 0.40 a 1.60 (Step 0.05).
MIX Table To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. iX3M Deep It is possible to set up to 10 mixes (3 for RATIO iX3M Deep). iX3M Tech+ Select the command NEXT =>...
Diluent Table for RATIO iX3M Tech+ & iX3M For iX3M Tech+ iX3M Reb To navigate the menu follow the instructions in the picture on the left. To reach this menu from the main screen press in sequence: D D D D ATTENTION: The diluents are active ONLY if the CCR mode is ON ATTENTION: The diluent 1 is always the starting one.
Dive Alarms To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. iX3M Deep The RATIO iX3M is equipped with colour visual, acoustic and vibrating alarms iX3M Tech+ C C C Do you know what?:...
NDL (Non Decompression Limit) Planner To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. The RATIO iX3M integrates a complete planner for square dives for both BUL & VPM PlANNER Attention: To modify the dive parametres set the device as desired entering the DEPTH:...
Decompression Planner To reach this menu from the main screen press in sequence To navigate the menu follow the instructions in the picture on the left. The RATIO iX3M integrates a complete planner for square dives for both BUL & VPM PlANNER Attention: To modify the dive parametres set the device as desired entering the DEPTH:...
Logbook To reach this menu from the main screen press in sequence To navigate the menu follow the instructions in the picture on the left. The first visualized dive is the most recent one. Do you know what?: The dive diagram shown in the RATIO iX3M’s Logbook is in HD and exploits at maximum the device screen’s definition.
SYSTEM SETTINGS From the main screen press buttons to have access to the menu. Use buttons A-B-C-D as described in the picture to navigate the menu. The selected entry is indicated in red colour. (According to your RATIO iX3M model some entries might not be visualized) SYSTEM SET MENU Do you know what?: DISPLAY...
Display Set To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. LEVEL: Ratio iX3M luminous intensity. From 1 to 15 MODE: It activates/deactivates the automatic (AUTO) or manual (MAN) back light mode.
General Set (ora e data) To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. UTC: Main time zone (0:00 Greenwich) UTC2: Secondary time zone gENERAl SET UTC: 1:00 Attention: in the Logbook only the UTC is registered, not the UTC2)
Reset to Default (reset the factory data) To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. D D D SETTINGS: Yes/No. It resets all menu entries to the factory settings. The command SETTING resets all menu and settings (MIX, Alarms, Colours etc.) It doesn’t reset the diver’s tissues saturation.
iX3M after a Tissue Reset After performing a tissue saturation reset the alarm “TISSUE RESET” is shown on the iX3M’s main screen. It warns the user that a Tissue Reset has been performed on the device. The device have to be used only by a person who does not have carried out dives during the previous 48 hours. You can ignore the message if you have NOT carried out any dive during the previous 48 hours.
Compass settings (Compass) To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left C C C C DECLINATION: The declination is meant to compensate the difference between the geographic and the magnetic north;...
Model, serial number and operative system. To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left. In this page you can visualize: Model name, serial number (S/N) and the installed operative system version (FW).
Compass To reach this menu from the main screen press in sequence: To navigate the menu follow the instructions in the picture on the left Compass resolution: 1° Compass accuracy: +/-1° Do you know what?: 0° The RATIO iX3M is provided with the most innovative compass. Check always a compass’ resolution and accuracy before entrusting it your route .
The RATIO iX3M when diving To navigate the menu follow the instructions in the picture on the left. When the iX3M is in the main screen or if it is switched off, it activates the dive mode automatically, once a certain depth is passed.
Dive Screen Main Data BATTERY: (on left top) residual battery % . TIME: (on right top) main time zone time. Current depth: (left) With colour alarm code when passing the gas MOD, mandatory stop and depth alarm. Dive Mode: (centre) Type of dive and used algorithm: OC= Open Circuit, CCR=Rebreather BUL= Bühlmann ZHL-16 B, VPM= VPM-B Dive Time:...
Page 52
If Safety Stop is activated: If the Safety Stop (recommended for any kind of dive) is activated, it will be shown on the computer’s central line during the ascent starting from a depth of 9 m. Do you know what?: You can customize the Safety Stop’s duration and depth from the menu DIVE SET If Deep Stop is activted: If the function Deep Stop has been activated, this is visualized 5 m before the...
Page 53
MIX: Mix currently used (it flashes in red if in the set of the scheduled mixes a better mix is available) PP02: O2 partial pressure of the currently breathed mix ASC: Ascent or descent speed expressed in mt/min (or ft/min) Low alarm level: if the ascent speed is >8 mt/min Medium alarm level: if the ascent speed is >9 mt/min High alarm level:if the ascent speed is >10 mt/min...
Current dive’s profile: To reach this menu from the main screen press in sequence: Current depth: (left) with coloured alarm code when passing the gas MOD, the mandatory stop and the depth alarm. Dive Mode: (centre) Kind of dive and used algorithm: OC= Open Circuit, CCR=Rebreather BUL= Bühlmann ZHL-16 B, VPM= VPM-B Dive Time:...
Decompression Chart: To reach this menu from the main screen press in sequence: This menu is available only if during diving you have accumulated decompression. D D D D D In this menu it is possible to visualize all decompression stops and the Mix that can be used among the ones expected for the current dive status.
Compass when diving To reach this menu from the main screen press in sequence: To navigate this menu follow the instructions shown in the picture on the left. Compass resolution: 1° Compass accuracy: +/-1° 29.6 Do you know what?: The iX3M has a highly innovative compass. Check always a compass’ resolution and accuracy before entrusting it your route.
Applications when diving To reach this menu from the main screen press in sequence: To navigate this menu follow the instructions shown in the picture on the left.. When diving, it is possible to use the following Applications: CHRONO (Cronometer) PITCH&ROLL (Level) APP MENU 29.6...
Mix change during the dive To reach this menu from the main screen press in sequence: ATTENTION: possible only if a If besides the bottom mix in the mix chart, decompressive mixes are set as well, the a better mix is available. computer will warn the user when it’s the right moment to change the mix, making the MIX area (on bottom left of the main screen) flash in red.
Setting change during the dive To reach this menu from the main screen press in sequence: To navigate this menu follow the instructions shown in the picture on the left MODE: OC/CCR (only for iX3M Tech+ and iX3M Reb) MIX: Mix percentage %O2/%He and mix’...
Mix change during the dive ATTENTION: The use of more mixes requires a suitable training. To navigate this menu follow the instructions shown in the picture on the left DO NOT use mixes without having received a suitable training! Press button to select the MIX (the selection is in red) Press button C to browse the Mixes previously set Press button...
Change Conservatism during the dive ATTENTION: To modify the GF or the R0 an adequate training is necessary. To navigate this menu follow the instructions shown in the picture on the left. Do NOT modify hte GFor the R0 In the example it is shown the value GFL/GFH; if you have chosen the VPM algorithm sarà the R0 if you don’t have received it!! will be visualized (for the iX3M Deep you’ll visualize the conservatism levels).
Change the set point during a dive ATTENTION: In order to use CCR and Set Point a proper training is required! iX3M Reb and iX3M Tech+ allow to manually change the SET POINT during the dive If you have not received that special training DO NOT use CCR mode !!! ATTENTION: Refer to “CCR Settings”...
The iX3M in GAUGE mode Use the Gauge mode as described in the example on the left. ATTENTION: To use the iX3M in GAUGE mode an gAUgE adequate training is necessary! TIMER AVg DEPTh To start the dive in GAUGE mode select the desired mode with button and start the dive.
Connect your iX3M to a PC or a Mac The iX3M can be connected to a Pc or to a Mac in order to download the dive data and to update the device. To connect the iX3M to your follow step-by-step this tutorial: http://www.ratio-computers.com/support/divelogger_win.htm To connect the iX3M to your follow step-by-step this tutorial:...
Update your iX3M Is very important to keep your iX3M always up-to-date. Subscribe the “Update alerts” service for free following the instruction in the next page. The iX3M can be connected with the USB cable to a Pc or to a Mac in order to update the device. To connect the iX3M to your in order to update your device follow step-by-step this tutorial: http://www.ratio-computers.com/support/update_win.htm...
Page 66
Warning! To receive all updates of this manual and notice of future updates of the “iX3M” by e-mail, please send a message writing “iX3M” update@ratio-computers.com to the following address: This service is highly recommended and it is completely free of charge. For further support, have a look at the tutorial videos soon available on www.ratio-computers.com...
Need help?
Do you have a question about the iXM3 and is the answer not in the manual?
Questions and answers