Operation Manual / A150-M56/66/57/67 - A155-M..
10 Dismantling and fitting with removed air inlet and gas outlet / 10.12
Installing the cartridge group
Fig. 70: Turning the cartridge group
Product
A150
A155
Table 49: Tightening torque (90012-01)
4. Re-fit the cross-piece of the service support (90012). Observe the tightening torque.
5. Place the protective cover over the compressor wheel.
6. Secure the second set of lifting gear to the cross-piece with a swivel lifting eye. The
length of the lifting gear must be selected in such a way that the compressor wheel is
not touched.
7. Turn the cartridge group into the vertical position of the rotor axis.
© Copyright 2021 ABB. All rights reserved.
Position
01
01
HZTL4032_EN
Tightening torque [Nm]
150
150
Rev.R
August 2021