Majestic fireplaces PVS-1 Homeowner's Installation & Operating Manual
Majestic fireplaces PVS-1 Homeowner's Installation & Operating Manual

Majestic fireplaces PVS-1 Homeowner's Installation & Operating Manual

Power venting system for use with decorative gas appliance models: nvc33vn/vp, nvc36vn/vp, nvc39vn/vp, nvc43vn/vp

Advertisement

Quick Links

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
WARNING: If the information in this
manual is not followed exactly, a fire
or explosion may result causing prop-
erty damage, personal injury or loss of
life.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbors phone. Follow
the gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Open windows / Extinguish all flames.
Power Venting System
Model: PVS-1
for use with
Decorative Gas Appliance Models:
NVC33VN/VP, NVC36VN/VP,
NVC39VN/VP, NVC43VN/VP
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Homeowner's Installation &
Operating Manual
C E R T I F I E D
51810 1/06 Rev. 2

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces PVS-1

  • Page 1 If you cannot reach your gas supplier, call the fire department. • Open windows / Extinguish all flames. PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Power Venting System Model: PVS-1 for use with Decorative Gas Appliance Models: NVC33VN/VP, NVC36VN/VP, NVC39VN/VP, NVC43VN/VP Homeowner’s Installation &...
  • Page 2: Installation Instructions

    ® Installation Instructions General information and instructions for the power vent system model No. PVS-1. NOTE: The PVS-1 will only work in conjunction with a VN Gas Valve P/N 57588 or VP Gas Valve P/N 57587. 1. This power vent system must be installed by a quali- fied installer in accordance with all applicable local...
  • Page 3 3. Vent System Termination Before installing Power Venter, determine location of vent system termination. 4. Location of the Fan To keep the noise level to a minimum, the fan should be located as far from the appliance as possible. A storage cupboard, or laundry area are preferred locations.
  • Page 4: General Venting Information - Termination Location

    Majestic Fireplaces Power Venting System ® General Venting Information - Termination Location VENT TERMINATION CFM145a A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window or door that may be opened C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’...
  • Page 5: Installation Restrictions

    Installation 1. Slip Sound Reducer into flue collar and press on to fireplace top. 2. Fasten Sound Reducer to fireplace top with four (4) sheet metal screws supplied. 3. Continue with the power venter installation as per instructions supplied with same. Fig.
  • Page 6 Majestic Fireplaces Power Venting System ® 18” (457mm) Minimum Fig. 5 An 18” (457mm) minimum vertical rise is necessary before a 90° elbow. FP1421 Min. vertical rise 11/25/03 djt Incorrect Fig. 6 Vent pipe transitions should be gradually tapered. Power Venter FP1423 Negative Pressure pipe transitions...
  • Page 7: Electrical Wiring

    Electrical Wiring WARNING: All 120 volt wiring must com- ply with applicable codes and ordinances. The optional power venter Model PVS-1 is equipped with a plug-in cord and an elec- tric knockout. When unit is wired directly the cord must be removed.
  • Page 8: Maintenance

    Majestic Fireplaces Power Venting System ® Operation and Checking the Draft 1. Insofar as is practical, close all doors, windows and air inlets to the building. Turn on all exhaust fans (range hood, bathroom exhaust, etc.) so they will operate at maximum speed. 2.
  • Page 9 Vibration Isolation Field Installed Power Venter Junction Box CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Power Venter Part List Mounting Bracket 1” Mounting Bracket 6”...
  • Page 10 Majestic Fireplaces Power Venting System ® 51810...
  • Page 11 Majestic Fireplaces Power Venting System ® 51810...
  • Page 12 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-525-1898 • www.cfmcorp.com...

Table of Contents