  • Page 1 Reach Ins Installation, Operation and Maintenance Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components immediately. See page 2. IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS! Printed 05/2020...
  • Page 2 Service and Installation Manual COMMERCIAL REFRIGERATOR SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. Our product instructions will be uploaded on our company official website. This is the Safety Alert Symbol.
  • Page 3 Service and Installation Manual The key for the appliances electric box should be kept safe by qualified persons in order to avoid a hazard WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Page 4 Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENT………………………………………..…………………4 SPECIFICATIONS…………………………………………………….……………………….………5 INSTALLATION………………………………………………………………………….…………..….6 OPERATION………..……………………………………………………………………..……………7 MAINTENANCE……………………………………………………………………….……………….9 WIRING DIAGRAM………………………………………………………………………………..11 All rights reserved. Reproduction of this manual without written permission is prohibited. SERIAL NUMBER INFORMATION The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand side near the top on the wall.
  • Page 6 Service and Installation Manual INSTALLATION Location Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds.
  • Page 7 Service and Installation Manual OPERATION Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet. CAUTION Refrigerated cycle Refrigerators: During the refrigeration cycle, the evaporator fans will run continuously even when one or more doors are open.
  • Page 8 Service and Installation Manual 1.1 Function of LEDS MODE SIGNIFICATO Compressor enabled Flashing Anti-short cycle delay enabled (AC parameter) Defrost in progress Flashing Dripping in progress Fans output enabled Flashing Fans delay after defrost Measurement unit Flashing Programming mode Measurement unit Flashing Programming mode 2.
  • Page 9 Service and Installation Manual MAINTENANCE The unit must be turned OFF and disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. DANGER Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and water or a nonabrasive liquid cleaner.
  • Page 10 Service and Installation Manual MAINTENANCE Cleaning solutions need to be alkaline based or non-chloride based. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used, be sure to rinse and dry thoroughly.
  • Page 11 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB19R MODEL:IB27R...
  • Page 12 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB54R MODEL:IB81R...
  • Page 13 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB27RG MODEL:IB54RG...
  • Page 14 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB19F MODEL:IB27F...
  • Page 15 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB54F MODEL:IB27FG OVERLOAD PROTECTOR PLUG LAMP SWITCH CONDENSEN COMPRESSOR DRIVER DOOR THERMOSTAT SWITCH LAMP DISPLAY CURRENT RELAY STARTING CAPACITOR ROOM EVAP SENSOR...
  • Page 16 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB54FG OVERLOAD LAMP PROTECTOR PLUG SWITCH CONDENSEN COMPRESSOR DRIVER DOOR SWITCH CURRENT LAMP THERMOSTAT DISPLAY RELAY STARTING CAPACITOR CAPACITOR EVAP ROOM SENSOR...
  • Page 17 Service and Installation Manual WIRING DIAGRAM MODEL: IB19R...
  • Page 18 Service and Installation Manual WIRING DIAGRAM MODEL: IB27R...
  • Page 19 Service and Installation Manual WIRING DIAGRAM MODEL: IB54 R...
  • Page 20 Service and Installation Manual WIRING DIAGRAM MODEL: I B81R...
  • Page 21 Service and Installation Manual WIRING DIAGRAM MODEL: I B27 RG...
  • Page 22 Service and Installation Manual WIRING DIAGRAM MODEL: IB54RG...
  • Page 23 Service and Installation Manual WIRING DIAGRAM MODEL: I B19F...
  • Page 24 Service and Installation Manual WIRING DIAGRAM MODEL: I B27F...
  • Page 25 Service and Installation Manual WIRING DIAGRAM MODEL: IB54F...
  • Page 26 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB27FG...
  • Page 27 Service and Installation Manual ELECTRICAL DIAGRAM MODEL:IB54FG...
  • Page 28 IBB81FDV THERMOSTAT DISPLAY...
  • Page 29 Two Year Parts & Labor Warranty MVP Group (IKON) warrants, to the original purchaser, all of its new equipment to be free from defects in material and workmanship, under normal use and maintenance service, for a period of two (2) years from the date of original purchase or 27 months after shipment date from the manufacturer, whichever occurs first.
  • Page 30 Service and Installation Manual BLANK PAGE...