  • Page 1 Installation Manual Domestic Hot Water Heat Pump Monobloc type Installation manual English Domestic Hot Water Heat Pump - Monobloc type RKHH2E200AAV33 RKHH2E260AAV33 RKHH2E260PAAV33...
  • Page 3 RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 4: Table Of Contents

    9 Maintenance and cleaning ..36 9.1 Resetting of safety equipment ....36 9.2 Quarterly inspections ......37 9.3 Annual inspections ......... 37 9.4 Cleaning of the ventilation filter ....37 RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 5: General Safety Precautions

    For more information, contact your installer or local authority. INFORMATION Indicates useful tips or additional information. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 6: For The Installer

    Do NOT touch the air inlet or aluminium fins of the unit. NOTICE • Do NOT place any objects or equipment on top of the unit. • Do NOT sit, climb or stand on the unit. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 7: Refrigerant

    • NOTICE When the refrigerant system needs to be opened, refrigerant must be treated Make sure water quality complies with EU according to the applicable legislation. directive 98/83 RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 8: Electrical

    Failure to do so may cause electric shock or fire. • When installing the earth leakage protector, make sure it is compatible with the inverter (resistant to high frequency RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 9: Glossary

    Field supply Equipment not made by Daikin that can be combined with the unit according to the instructions in the accompanying documentation. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 10: Introduction

    In the interest of achieving technical perfection, we reserve the right to carry out modifications to the equipment construction or to data at any time whatsoever. We therefore do not accept any RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 11: Available Versions And Configurations

    Air source heat pump for the production of RKHH2E260AAV33 domestic hot water RKHH2E260PAAV33 Air source heat pump for the production of domestic hot water suitable for use with the solar power system. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 12 When transporting the equipment horizontally, the display must be facing up. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 13: Construction Characteristics

    (G 1” ; 1 m surface). Cold water inlet connection joint (G 1”). 50 mm polyurethane insulation. Automatic resetting safety pressure switch. Air inlet filter. ½”G fitting for thermistor immersion sleeve RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 14: Technical Characteristics

    AUTOMATIC cycle Compressor Rotary Compressor protection Thermal circuit breaker with automatic reset thermodynamic circuit protection Safety pressure switch with automatic reset type Centrifugal Ejection outlet diameter Revolutions per minute 1650÷2100 RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 15 UNI EN 12897-2006 measurements carried out according to UNI EN 16147-2011 measurements carried out according to EN 12102-2013 automatic activation every 30 days of operation RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 16: Important Information

    N.B. being caused. Moreover, it is necessary Maintenance and disposal operations must be to arrange for a back-up service in case carried out by qualified personnel. of failure! RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 17: Installation And Connections

    Have containment systems in case of serious water leaks; • Be sufficiently lit (where appropriate); • Fig. 4 – Example of dual duct connection Be larger than 20 m • Be frost-proof and dry. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 18: Particular Installation Conditions

    Fig. 5b – Example of installation in winter Keep the doors to the boiler room closed and hermetically sealed if there is no combustio air supply between the inhabited areas and the boiler room.” RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 19: Device Mounting And Connection

    Fig. 6 – Overall dimensions  D   2000 1391 1085 (*1) (*1)  P 337,5  (*1) I and J only for RKHH2E260PAAV33 Fig. 7 – Water supply connections RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 20: Condense Drain Connections

    The residual hardness should not fall below 15°F. PLEASE NOTE! It is advisable for the system installer to install a 7-bar safety valve on the cold water intake pipe (Fig. 8a). RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 21: Solar Power System Integration

     Spring check valve  Drain tap  Solar thermal power coil  Hot water outlet pipe Fig. 10 – Example of solar power system integration RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 22: Electrical Connections

    62°C to 70°C occurs because of the immersion electric heating element (if SP6 is the same as SP5, the electric heating element will never activate). RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 23: Wiring Diagram

    Press the power key (see paragraph 0), the equipment will start in “ECO” mode (default setting) 5 minutes after pressing the key. port 1 (upon request) supply Fig. 15 – Wiring diagram RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 24: Operation And Use

    Maintenance If lit: maintenance of the air switch on at certain time slots and filter is required (if independently enables the anti-Legionella and present) defrosting functions. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 25: Operating Logic

    Automatic or Economy mode, depending on which one was previously set by the user; RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 26 8.1.3.6 Timeslot settings for the switching on/off • Press and hold the and the keys until: of the equipment “Loc” will appear on the display for 1 second. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 27 Carefully evaluate enabling of time slot operation the evaporator; in order to avoid malfunctions caused by If the equipment is in the “stand-by” mode, the users. • display will be switched off. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 28 - Switch off the equipment and restart it, or equipment is restored. disconnect the equipment from the mains power supply. Main consequences: - Compressor will be switched off; RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 29 60 seconds. Alternatively: • Press and release the key. Prior to performing operations within timeslots, you should have carried out the settings relating to the day and the real time. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 30 Press and release the key. To exit the procedure: • Press and release the key or do not carry out any other operation for 60 seconds. Alternatively: • Press and release the key. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 31: Particular Operations

    The system verifies the environmental conditions cyclically (i.e. every 120 minutes) and activates the heat pump mode only when the conditions are adequate for its operation. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 32: List Of Equipment Parameters

    Minimum auto cycle set point °C/°F 10.0 40.0 Maximum auto cycle set point °C/°F 100.0 70.0 Minimum economy cycle set point °C/°F 10.0 40.0 Maximum economy cycle set point °C/°F 100.0 56.0 RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 33 1 = Absolute Minimum level AL1 alarm delay due to equipment start-up (only warning) AL1 and AH temperature alarm delays (only warning) Alarm hysteresis 30.0 Heating element start-up interval (Anti- days Legionella) RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 34 00:00 23.59 --:-- --:-- = Function excluded Equipment address ---- 0 = 2400 1 = 4800 Baud Rate ---- 2 = 9600 3 = 19200 Parity ---- 0 = NONE RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 35 Parameter description Code U.M. Default Notes 1 = ODD 2 = EVEN RESERVED ---- RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 36: Maintenance And Cleaning

    4 mm; elements but not the heat pump system • within the permitted operating limits. Reassemble the upper cover that was previously removed. Fig. 18 – Removal of upper cover RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 37: Magnesium Anodes

    9.5 Magnesium anodes The magnesium anode (Mg), also "sacrificial" anode, avoids any parasitic currents, generated inside the boiler, that can trigger corrosion processes on the device surface. RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 38: Troubleshooting

    The main materials that are used in the production of the equipment are as follows: • Steel; • Magnesium; • Plastic; • Copper; • Aluminium; • Polyurethane. RKHH2E-(P)AAV33 Installation Manual ROTEX Domestic Hot Water Heat Pump 2018.8...
  • Page 39 Annual electricity consumption in kWh 1091 1826 1826 under colder climate conditions Annual electricity consumption in kWh 1296 1296 under warmer climate conditions Sound power level Lwa outdoors in dB RKHH2E-(P)AAV33 ROTEX Domestic Hot Water Heat Pump Installation manual 2018.8...
  • Page 42 Unsere Partner im Ausland Our partners abroad • Unsere Partner im Ausland Nos partenaires à l’étranger • Le nostre sedi all'estero Neustros representantes en el extranjero Nasi partnerzy za granicą • Naši partneři v zahraničí http://de.rotex-heating.com > ueber-rotex > international 2018.8...