Do Not kink, crush, drag or drive over the mains cable and protect it from sharp edges oil and heat.
8
Do Not use extension cables.
8
Always disconnect from the mains supply before attempting any maintenance etc.
9
When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
9
location.
WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.
2. iNtroDuctioN
manufactured from heavy-duty corrosion resistant materials with polypropylene motor case and base cover. Fitted with an automatic cut-out,
which can be set at multiple heights using an innovative cable fixed mounting bracket. Minimum water depth of just 5mm. Designed for clean
water although these pumps will accept small particles up to 5mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the
general transfer of water.
3. SpeciFicatioN
model no
wpc100p
Cut out
Automatic
outlet od
32mm
maximum output/min
100ltr (22gal)
maximum output/hr
6000ltr (1320gal)
maximum head
6mtr
maximum water depth
7mtr
minimum water depth
5mm
maximum particle size
5mm
motor power
250W
Supply
230V
Weight
4.09kg
4. iNStallatioN
4.1.
Attach a sufficiently long and strong rope to the handle
before first use. The pump is submerged into the liquid
on this holding rope and can also be carried with it as
well as the handle.
Note: Do Not suspend unit by the power cable.
Note: With continuous use of the pump, the condition
of the rope must be regularly checked as it can decay
and break over time.
4.2.
coNNect preSSure pipe
4.2.1.
For occasional use, use a suitable water hose.
4.2.2.
The use of rigid pipes with a non return valve is
recommended for use at a fixed location. This prevents
return flow of liquid when switching off.
4.2.3.
Screw the pressure line onto the pressure connection.
4.2.4.
All threaded connections must be sealed with thread
sealing tape.
4.2.5.
When using a hose, screw a suitable hose adaptor onto
the pressure connection. Push the hose firmly onto the
hose adaptor and secure with a hose clamp.
4.3.
iNStallatioN
4.3.1.
The pump needs an area of at least 50cm x 50cm (the float switch must be able to move freely so that it functions properly.
4.3.2.
The pump can be submerged under water to the submerged operating depth of 7metres.
4.3.3.
Install the pump so that the suction openings cannot be blocked by foreign bodies (place the appliance on a firm, even base if
necessary.
4.3.4.
ensure that the pump is stable.
Do Not lift the pump with the cable or the pressure hose as these are not designed for the tensile stress from the weight of the pump.
8
4.3.5.
Submerge the pump at an angle into the liquid to be delivered, so that no air pocket forms on the underside of the appliance. Suction
would be prevented by this. once the pump is submerged, it can be righted again.
4.3.6.
Leave the pump at the bottom of the liquid container. Use a strong rope attached to the carrying handle of the pump for lowering.
4.3.7.
Tighten the end of the rope firmly after lowering.
4.3.8.
The pump can also be operated whilst suspended on a rope.
Note: For operation whilst suspended on the rope, Do Not operate without the pressure hose. Avoid the pump twisting round its
longitudional axis.
5.
operatioN
5.3.1.
Connect the pump to mains supply.
warNiNG! The float switch must be able to move so that the submersible pump cannot run dry, doing so would cause damage to the
unit.
5.3.2.
The float switch can be set at different heights by affixing it to a different slot on the unit's body, see picture above.
© Jack Sealey limited
wpc150p
wpc235p
Automatic
Automatic
32mm
38mm
183ltr (40gal)
217ltr (48gal)
11000ltr (2420gal)
13000ltr (2860gal)
8.5mtr
8.5mtr
7mtr
7mtr
5mm
5mm
5mm
5mm
550W
750W
230V
230V
4.98kg
5.02kg