INSTALLATION 1.0 LOCATION The cabinet must not be tilted. If necessary, some models may be tilted to the side indicated on the packaging. If not, it cannot be tilted. You must wait for at least 2 hours from standing the cabinet up before starting it up.
1.1 CLEANING Now that our cabinet is correctly installed, we must proceed to cleaning it: The first cleaning must be carried out with water and neutral detergent. Once clean and dry, insert the accessories in the appropriate places, as you prefer. We recommend cleaning the outside of the unit daily with a damp cloth and following the direction of the stainless steel’s polished finish.
1.3 MATRICULATION PLATE Explanation of the matriculation plate that comes with your cabinet MATRICULATION PLATE NUMBER DESCRIPTION CONSTRUCTION COMPANY MODEL SERIES NO. REFRIGERATION POWER WATTS WORKING VOLTAGE FREQUENCY CURRENT INTENSITY TYPE OF COOLANT GAS GRAMS OF COOLANT GAS CLIMATIC CLASS (T=4) STANDARD Note: This plate is an example.
2.0 USE AND LOCATION RESTRICTIONS. This machine must not be placed outdoors, and must be protected from rain and direct sunlight. Environmental conditions: see characteristics plate. This equipment is not designed to store explosive substances such as aerosol cans with flammable propellant. WARNING: The appliance contains in the refrigerant circuit the refrigerant propane (R290) or isobutane (R600a), a highly environmentally compatible natural gas that is inflammable.
Temporary interruption of the power supply. If the interruption does not exceed 20 minutes, it is not necessary to take any precautions, just avoid opening the doors as far as it is possible, to prevent the temperature from rising. If the interruption exceeds 20 minutes, you must make sure that the food does not exceed the critical points, checking that it is not affected and avoid opening the doors.
3.1 MANUAL DEFROST AND CLEANING To ensure maximum performance whenever the machine if it is advisable to perform a manual defrost when the thickness of the frost exceeds 5 mm. Follow the steps below: - Remove the product and place it in a refrigerator at -18 º C - Shut down the main switch and disconnect the plug.
3.3 SPECIAL MAINTENANCE (Authorised technical personnel) Check that the premise's temperature does not exceed that indicated for your cabinet. The guarantee will be made void if there is insufficient ventilation. Check that the doors close properly. Do not disassemble the mobile components guards without first having turned the appliance ...