Xtreme SNMP-2PV2 User & Installation Manual

Xtreme SNMP-2PV2 User & Installation Manual

Web/snmp cards

Advertisement

Quick Links

Web/SNMP Cards
SNMP-1PMINI, SNMP-1PIN, SNMP-R90, SNMP-USB, SNMP-3PEX, SNMP-2PV2 models
User & Installation Manual
www.xpcc.com
| © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 12/27/18)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SNMP-2PV2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Xtreme SNMP-2PV2

  • Page 1 Web/SNMP Cards SNMP-1PMINI, SNMP-1PIN, SNMP-R90, SNMP-USB, SNMP-3PEX, SNMP-2PV2 models User & Installation Manual www.xpcc.com | © 2015 Xtreme Power Conversion Corporation. All rights reserved. (Rev 12/27/18)
  • Page 2: Table Of Contents

    Using ClientMate...........................51 SNMPView – Windows Based UPS Management System......57 Introduction...........................57 System Requirements........................58 Install SNMPView..........................58 Using SNMPView...........................58 SNMPView Buttons........................59 Appendix A: Update the Firmware of NetAgent UPS........75 Appendix B: 3 Ports NetAgent II with SMS Modem........78 Xtreme Power Conversion Corporation Page 2...
  • Page 3 Web/SNMP Cards UPS Management Appendix C: SMS Server with SMS Modem..........81 Xtreme Power Conversion Corporation Page 3...
  • Page 4: Introduction

    SNMP-3PEX can be used to connect the environmental monitoring utility, SNMP-EMP, to get the temperature/ humidity/smoke/fire indications. This information can also be displayed on the NetAgent Web page. When an abnormal condition happens, it can also be sent as a trap to the system manager. Xtreme Power Conversion Corporation Page 4...
  • Page 5 SNMP-3PEX and SNMP-EMP. The system manager could continuously monitor these environmental condi- tions over a Web browser. NetAgent Connection Software SNMP-3PEX Diagram Xtreme Power Conversion Corporation Page 5...
  • Page 6: Netagent Models

    3. User Manual 4. 5.3V DC adapter 1. Internal NetAgent Mini with LCD Display 2. NetAgent Utility CD SNMP-USB External 3. User Manual 4. 5.3V DC adapter Pictures of NetAgent Web/SNMP Cads SNMP-1PIN SNMP-3PEX Xtreme Power Conversion Corporation Page 6...
  • Page 7 M2502 (or M2505) Cable: For external NetAgent II connection to RS-232 UPS. • M2506 Cable: For connection SNMP-3PEX and Modem. • 9V DC Adapter: For SNMP-3PEX • 5.3V DC Adapter: For SNMP-R90 or SNMP-USB NetAgent Outlook SNMP-1PIN Xtreme Power Conversion Corporation Page 7...
  • Page 8 Solid ON Normal operation Solid ON Flashing Solid ON No connection to UPS Writing data to flash Flashing Flashing Solid ON memory Green light: Power state Red light: Connection state with UPS SNMP-1PMINI SNMP-2PV2 Xtreme Power Conversion Corporation Page 8...
  • Page 9 Light flashes when Netagent transmits command to UPS Light signal application - LAN Port LED Light color Condition description On: Internet correspond speed is 100M Green Flash: Data transmitting On: Internet correspond speed is 10M Yellow Flash: Data transmitting Xtreme Power Conversion Corporation Page 9...
  • Page 10: Netagent Ups Installation

    You could also install the shutdown utility – ClientMate to protect your Windows operating system. And also could use the UPS management software – SNMPView, to control and manage multiple UPS on the network. NetAgent UPS installation flowchart Xtreme Power Conversion Corporation Page 10...
  • Page 11: Netagent, Ups And Network Connection

    NetAgent provides external and internal model for different UPS interface requirement. Please reference the fol- lowing description for detailed information of UPS and network connection. Install the NetAgent with UPS and Network For SNMP-1PMINI & SNMP-2PV2 • Please make sure the connector direction of the cable is correct before connecting to the NetAgent.
  • Page 12 Plug the DC adapter to UPS outlet, the DC plug connects with NetAgent. SNMP-USB Installation Warning: Please make sure the input Voltage and Frequency of the DC power adapter (NetAgent II – DC 9V / Xtreme Power Conversion Corporation Page 12...
  • Page 13: Using Netility Setup Ip. Update Firmware

    Choose the NetAgent from the right of the screen, then click “Configure”, which shows the following setting page. IP Address: Set IP address for Netagent UPS When using for the first time, please set IP address; subnet mask; and gateway. After setting, enter IP address Xtreme Power Conversion Corporation Page 13...
  • Page 14 Set 81 as HTTP port number, then http://192.168.0.177:81 must be typed at the web address to proceed to Netagent UPS’s web page. • Set 23 as Telnet port number, then “192.168.0.177:24” must be typed at Telnet to proceed to the Telnet screen of NetAgent UPS. Xtreme Power Conversion Corporation Page 14...
  • Page 15 Net Agent will auto reboot. To upgrade multiple NetAgents simultaneously with the same firmware, hold the “Shift” or Ctrl” key and choose the NetAgent device from Netility list. (Please visit to http://www.megatec.com.tw for the latest firmware) If upgrading multiple units, select When upgrade firmware to multiple NetAgent. Xtreme Power Conversion Corporation Page 15...
  • Page 16 Netility version examined Refresh List - Search Lan’s Netagent UPS manually Netility can search for all of the available NetAgent on Lan automatically, or the user can search manually by clicking on “Search NetAgent”. Xtreme Power Conversion Corporation Page 16...
  • Page 17: Ups Web Management By Netagent

    Enter the selection item, the sub-menu items will be shown on the left side of the page. When using this NetA- gent for the first time, please enter the [Configuration] menu item to set all the configuration items. Then the UPS status will be accurately shown on other pages. Xtreme Power Conversion Corporation Page 17...
  • Page 18 Web/SNMP Cards UPS Management NetAgent UPS - single port NetAgent UPS - 3 ports NetAgent 9 Xtreme Power Conversion Corporation Page 18...
  • Page 19 This page is to show UPS basic information. Values here are either provided by the UPS or they are user settings from the Configuration pages. UPS Information Information about UPS Manufacturer/UPS Firmware Version/UPS Model are provided by the UPS. Xtreme Power Conversion Corporation Page 19...
  • Page 20 Values here will be shown in red when an abnormal status condition occurs. Battery Status This section is to show the UPS Battery Status, including Temperature/Battery Status/Battery Capacity/ Battery Voltage/Time on Battery..etc. Values here will be shown in red when an abnormal status condi- tion occurs. Xtreme Power Conversion Corporation Page 20...
  • Page 21 When the UPS is put into Sleep mode, it will not provide output power. The UPS will provide power again after Sleep mode time is complete. Wake up UPS When initiated, UPS will be awakened from sleep. Xtreme Power Conversion Corporation Page 21...
  • Page 22 This is to trigger UPS buzzer On. If its ON already, initiating this command will set it OFF. Remote Control Meter/Chart This page displays temperature, capacity, load, voltage..etc of the UPS by appearing with meters/chart diagram. Meter/Chart Xtreme Power Conversion Corporation Page 22...
  • Page 23 This page displays Modem’s status and information when 3 port NetAgent II connects with modem. Modem Information This section displays the modem information. GSM Modem Operating Status This section displays the operating status between NetAgent and Modem. Xtreme Power Conversion Corporation Page 23...
  • Page 24 This section is to show smoke presence (ie. fire) which is detected by smoke sensors. Security Status (Security1 ~ Security7) This section is to show open/close status for doors and windows. One NetFeeler II can monitor up to 7 Security Sensors. Xtreme Power Conversion Corporation Page 24...
  • Page 25 This section is to record the date when the UPS battery was last replaced. UPS Recorded UPS Data Log This section is to set how often the UPS data should be logged. Test UPS Xtreme Power Conversion Corporation Page 25...
  • Page 26 Critical Capacity (%) This section is to set the UPS critical battery capacity (shown as % )NetAgent will send warning messages when UPS battery level goes below this value. UPS Configuration UPS On/Off Schedule Xtreme Power Conversion Corporation Page 26...
  • Page 27 This section is to wake the PC within the network. (Make sure the PC supports this function and config- ure as “Enabled” under BIOS.) Enter the IP address of that PC and system will search its IP accordingly. UPS On/Off Schedule Network Xtreme Power Conversion Corporation Page 27...
  • Page 28 This is the Domain Name you have created from the above selected DDNS provider. Login Name This is the Login / Account name that you have created with the selected DDNS provider. Login Password Xtreme Power Conversion Corporation Page 28...
  • Page 29 NetAgent will automatically dial up and maintain continuous connection. Login Name Enter the login name assigned by your ISP. Login Password Enter the password assigned by your ISP. Note: System will reboot if any configuration change applies Network SNMP Xtreme Power Conversion Corporation Page 29...
  • Page 30 This section is to set a Community name for NMS. The community name has to be the same as the set- ting in NMS. Trap Type This section is to select if whether to send trap using PPC MIB or RFC1628 Severity Xtreme Power Conversion Corporation Page 30...
  • Page 31 This section is to select events for NetAgent to send traps. Clicking on Select will open a Select Events List. Or, Click on Test to send test trap. Event Traps may be selected from this list. Events list is below: UPS Events Device Connected Xtreme Power Conversion Corporation Page 31...
  • Page 32 NetAgent is connected to. SNMP UDP This is to configure the UDP port of the NetAgent and trap receiver. SNMP default port is 161; and Trap MIB is UDP162 SNMP NetAgent 9 SNMP Email Xtreme Power Conversion Corporation Page 32...
  • Page 33 Send email when Event Log overflows (500 records) Select YES to have NetAgent send a warning email stating Event Log has reached 500. The data will now be purged to make room for new data. Xtreme Power Conversion Corporation Page 33...
  • Page 34 SMSAgent. Select Disable if not needed. SMS Server, SMS Server Port This section is to set the IP address of the SMSAgent or PC if selected remote service. (e.g. 192.168.0.180) and Port Number (default:80) Account Name, Password Xtreme Power Conversion Corporation Page 34...
  • Page 35 Note: 1) Enter mobile number same as sending from mobile. Note: 2) Please refer to SMSAgent’s user manual for further information. Note: 3) See Appendix for further information NetAgent 9 SMS Modem (For 3 Ports NetAgent II only) Xtreme Power Conversion Corporation Page 35...
  • Page 36 4. UPS Battery Low 5. UPS Temperature Overun 6. When battery capacity reaches to % NetFeeler II (environmental sensor) 1. Temperature Overrun/Underrun 2.Humidity Overrun/Underrun 3. Water 4. Smoke 5. Gas 6. Security (Door/ Windows 1~7) Xtreme Power Conversion Corporation Page 36...
  • Page 37 RADIUS Server Address To enter the IP address of the radius server Authentication Port To enter the UDP communication port number Shared Key This is to enter the password to login to radius server Xtreme Power Conversion Corporation Page 37...
  • Page 38 This is to upload the SSL certificate. When both public key and certificate are uploaded to NetAgent web server, the communication will be encrypted by SSL on the Internet by entering with Http:// on the browser. (To communicate via Https, make sure to enable Https port 443.) WEB/Telnet Xtreme Power Conversion Corporation Page 38...
  • Page 39 This section is to set a different time zone for different countries. Using Daylight Saving Time Choose between Yes or No System Time (yyyy/mm/dd hh:mm:ss) This section is to set NetAgent system time manually. Set this in the format: yyyy/mm/dd hh:mm:ss Xtreme Power Conversion Corporation Page 39...
  • Page 40 This only applies on BX NetAgent models and the USB flash disk must be with FAT/FAT32 format Time Between Log Backup To configure the time in hour to save log file. System Time NetAgent 9 System Time Xtreme Power Conversion Corporation Page 40...
  • Page 41 Users can also choose the languages they prefer from the “Interface Language” list. Note: Users will have to enable cookies before they use this function. Email Preferences Select language preference when receive emails and SMS. Xtreme Power Conversion Corporation Page 41...
  • Page 42 This page is a UPS Event log. It shows a record of all events, giving the Date/Time of the event and a detailed description of each. When reach to the limit, it rewrites on the previous logs Xtreme Power Conversion Corporation Page 42...
  • Page 43 This page is a SMS Event log. It shows a record of all mobile number, giving the Date/Time of the SMS sent and a detailed description of each. When reach to the limit, it rewrites on the previous logs Xtreme Power Conversion Corporation Page 43...
  • Page 44 This section shows records of the UPS internal temperature. (unit: degrees Centigrade) Env. Temp. This section shows environmental temperature which detected by NetFeeler II Env. Humidity This section shows environmental humidity which detected by NetFeeler II Xtreme Power Conversion Corporation Page 44...
  • Page 45 UPS Management Date Log Save Data Log This function is to record RS232 UPS’s voltage, frequency, load, capacity, temperature..etc to save as another file for the other purpose to the manager. Save Data Log Xtreme Power Conversion Corporation Page 45...
  • Page 46 Debug mode is set as manually, user may enter its parameter under Send Contents column. Sent Information This column shows the real time sent command Received Information This display the response that NetAgent receives from UPS Xtreme Power Conversion Corporation Page 46...
  • Page 47 This function will reset all settings to its default value. Firmware Update Setting Default FTP server is set as ftp.icv99.com with its username/password. Click on Update Now, NetAgent will connects to the FTP server and upgrade to the latest firmware version accordingly. Xtreme Power Conversion Corporation Page 47...
  • Page 48: Telnet (Remote Configuration)

    NetAgent to monitor and control UPS. Here are introduction for using Telnet. Telnet Configuration • Select “Start” from Windows, click “Run” to key-in NetAgent IP Address Telnet startup Xtreme Power Conversion Corporation Page 48...
  • Page 49 Note: The configuration of ‘Set SNMP Trap Receiver’ is only used for SNMP Network Manager. 5. Set UPS Properties This allows you to setup the Communication Type of UPS, UPS Device Name and Battery Replacement Date. Xtreme Power Conversion Corporation Page 49...
  • Page 50: Telnet Configuration

    Use Putty software to configure SSH Telnet encryption on NetAgent 9. This only apply to NetAgent 9 models of CX, DX and BX. Following is the configuration of SSH Telnet • Enter the IP address of NetAgent 9 and click on Enter • Enter the username / password Xtreme Power Conversion Corporation Page 50...
  • Page 51: Clientmate - Windows Shutdown Utility

    Click “ClientMate” to initiate the ClientMate and start using the ClientMate. Using ClientMate Please find the ClientMate main window here below:press the left icon to enter the configuration dialog. On the right of the window is the current status of the UPS. Xtreme Power Conversion Corporation Page 51...
  • Page 52 When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals, the ClientMate will based on the configuration below to initiate the shutdown process. The details of the configura- tion are here below. ClientMate: Configuration Xtreme Power Conversion Corporation Page 52...
  • Page 53 To configure to shutdown when battery capacity meets at _ % 11. Auto save application files Check if to save the application files before system shutdown 12. Run Application before shutdown computer Execute the application before system shutdown. Xtreme Power Conversion Corporation Page 53...
  • Page 54 User could review all the files closed during previous shutdown process. If the “Auto save application files” func- tion has been turn-on in the “Setting” dialog, the details of the closed application and files could be reviewed here. Xtreme Power Conversion Corporation Page 54...
  • Page 55 Press this button could review the version information of the ClientMate, as here bellowed. ClientMate:About Event log Press this button could review all the network status and UPS status happened. Shown as below. ClientMate:About Xtreme Power Conversion Corporation Page 55...
  • Page 56 The connected NetAgent UPS AC power is normal. The connected NetAgent UPS AC power is failed. AC power status Status ICON Description The connected NetAgent UPS AC power is normal. The connected NetAgent UPS AC power is failed. Xtreme Power Conversion Corporation Page 56...
  • Page 57: Snmpview - Windows Based Ups Management System

    UPS condition displayed in either a graphic or analog bar chart. • Supports MegaTec’s SNMP Agent and SNMP Internal Card. • Able to send email for notification • Able to send SMS for notification Xtreme Power Conversion Corporation Page 57...
  • Page 58: System Requirements

    After the SNMPView program start up the main windows will be displayed. The left panel will list the available stations by area and the right panel will list the UPS, Host Name, Startup Time, Manager and Location of UPS found in each station. Xtreme Power Conversion Corporation Page 58...
  • Page 59: Snmpview Buttons

    If the host is a UPS, just click on it to view and modify the UPS’s general information Monitor If the host is a UPS, just click on it to start monitoring UPS View Display in either, Large icons, small icons or details Xtreme Power Conversion Corporation Page 59...
  • Page 60 When press, SNMPView will start a search for all the NetAgent on network and list them in the main window. Add Group This is to edit or display all the group station of NetAgent under network Xtreme Power Conversion Corporation Page 60...
  • Page 61 Highlight the unit to be deleted from main list and right click on it to choose Delete or use click on the Delete icon from main function list. Hold On “Shift” to select multi NetAgent UPS Browse Device Highlight the unit to be browsed and click it to enter NetAgent’s webpage. Xtreme Power Conversion Corporation Page 61...
  • Page 62 Web/SNMP Cards UPS Management Export Configuration This is to save the NetAgent UPS’s configuration Import Configuration This is to import the configuration of NetAgent UPS that saved Xtreme Power Conversion Corporation Page 62...
  • Page 63 Open up “SnmpElog.dat”, SNMPView would show the event log of all NetAgent UPS: Open up “SnmpElog.dat”, event log would show as below: Open archive Data Log Open up “SnmpDlog.dat”, SNMPView would show the event log of all NetAgent UPS: Xtreme Power Conversion Corporation Page 63...
  • Page 64 Web/SNMP Cards UPS Management Open up “SnmpDlog.dat”, data log would show as below: Quit Exit SNMPView View(s) This is to choose the presentation format of NetAgent UPS. Xtreme Power Conversion Corporation Page 64...
  • Page 65 Detailed Information displays NetAgent UPS’s IP address, name, input voltage, output voltage, battery capacity, load, frequency..etc. Map Background Import a map image (JPG) by right click on the main screen and move NetAgent UPS icon to its suitable location. Xtreme Power Conversion Corporation Page 65...
  • Page 66 SMTP server address: Enter SMTP address, IP address or domain name. • Server requires authentication: Click Setting, then enter your Account Name and Account Password. • Notified Email Address: Click add and enter new email address. Xtreme Power Conversion Corporation Page 66...
  • Page 67 Web/SNMP Cards UPS Management SMS Notification Send SMS when event occurs Trap List Double click on the trap that listed and configure Xtreme Power Conversion Corporation Page 67...
  • Page 68 UPS Monitor Highlight NetAgent UPS device and configure. Or right click on the highlighted device and click on monitor device Meter Display NetAgent UPS information such as input voltage, output voltage, temperature, capacity..etc in diagram. Xtreme Power Conversion Corporation Page 68...
  • Page 69 Web/SNMP Cards UPS Management Digital Display NetAgent UPS information such as input voltage, output voltage, temperature, capacity..etc in digital. Details Display NetAgent UPS’s IP address, location, user, manufacturer and all other detailed information Xtreme Power Conversion Corporation Page 69...
  • Page 70 Sleep Time: To set UPS sleep time. Test Period • Unknown: This defined by UPS configuration. • Two weeks: Perform UPS test every two weeks • Weekly: Perform UPS test every week • Disable: Do not perform UPS test Xtreme Power Conversion Corporation Page 70...
  • Page 71 Web/SNMP Cards UPS Management UPS Magaement To configure SNMP of its NetAgent UPS Xtreme Power Conversion Corporation Page 71...
  • Page 72 To view event log, data log and configuration Event Log Display event log , date/time and description of all NetAgent UPS Data Log Display input voltage, output voltage , frequency ,load...etc of all NetAgent UPS Xtreme Power Conversion Corporation Page 72...
  • Page 73 Total of 8 users account can be created to manage and control its NetAgent UPS Change Password To change existing user’s password to login User Management This only for Admin user to add, edit or remote other user’s info Xtreme Power Conversion Corporation Page 73...
  • Page 74 Web/SNMP Cards UPS Management Help(H) Display the current SNMPView version, and operation information HTML Help This to check the operation of SNMPView About Display the current SNMPView version, Copyright information and product service contact. Xtreme Power Conversion Corporation Page 74...
  • Page 75: Appendix A: Update The Firmware Of Netagent Ups

    “admin” and nothing under password. (press “Enter”). - Once the account and password been checked, the server will response with 230 OK to indicate Login Xtreme Power Conversion Corporation Page 75...
  • Page 76 , when using this method to enter, the follow error message will be show. At this moment, select “Enter Identity” at the top left corner of file menu. Then enter admin as account name and password to re-enter again. Xtreme Power Conversion Corporation Page 76...
  • Page 77 Web/SNMP Cards UPS Management Once the connection been established, the following window will be display. Then the user may transfer the latest firmware to here for the replacement in order to complete the updating steps. Xtreme Power Conversion Corporation Page 77...
  • Page 78: Appendix B: 3 Ports Netagent Ii With Sms Modem

    BP506 & SMS MODEM Hardware Installation A. GSM MODEM B. GSM MODEM Adaptor C. NetAgent BP506 D. GSM MODEM Cable E. RS232 to RJ45 Cable 2. How hardware should be connected 3. Before use GSM MODEM, insert SIM Xtreme Power Conversion Corporation Page 78...
  • Page 79 2. Modem communication Type→Select SMS 3. SMS Communication→Select GPRS 4. Enter SIM Card PIN(leave blank if none) 5. Click on Apply 5. Under Modem status of BP506 webpage, it indicates the status of Modem Xtreme Power Conversion Corporation Page 79...
  • Page 80 UPS Management BP506 SMS Configuration BP506→Configuration→ 1. SMS 2. Select Local Modem 3. Enter BP506’s username and password(leave none leave blank) 4. Enter Mobile number 5. Select events to send 6. Click on Apply Xtreme Power Conversion Corporation Page 80...
  • Page 81 2. Connect DC adaptor to GPRS modem as well serial cable provided to PC com port NOTE: Please make sure there is no conflict port with the GPRS modem SMS SERVER Software Installation 1. Click on exe for installation Xtreme Power Conversion Corporation Page 81...
  • Page 82 Web/SNMP Cards UPS Management 2. Once installed, the icon would appear on the tool bar 3. Right click on the SMS server icon and check modem status 4. SMS Server Software Configuration Xtreme Power Conversion Corporation Page 82...
  • Page 83 Service password: Password authentication for sending SMS (Leave blank if no such setting) To send SMS when event occurs: Yes or No 3. Enter mobile number to receive event by SMS 4. Select the event that needs to be send 5. Click Apply Xtreme Power Conversion Corporation Page 83...

This manual is also suitable for:

Snmp-1pinSnmp-r90Snmp-usbSnmp-3pexSnmp-1pmini

Table of Contents