Fitting The Gas Inlet Casing (≥ A180-L); Fig. 54: Fitting The Gas Inlet Casing (A180-L And Larger) - Screwed Variant; Table 37: Tightening Torque (61009) - ABB A165-L35 Operation Manual

Hide thumbs Also See for A165-L35:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
8 Disassembly and assembly / 8.17 Fitting the gas inlet casing (≥
A180-L)
8.17
Fitting the gas inlet casing (≥ A180-L)
8.17.1
Variant with screws
Fig. 54: Fitting the gas inlet casing (A180-L and larger) – screwed variant
Product
A180-L
A185-L
A190-L
Table 37: Tightening torque (61009)
1) Pre-tightening torque of the screws
1. Fit two guide studs (90317) in the upper area on the gas outlet casing (61001).
2. Loop around the gas inlet casing (51001) with the lifting gear and secure it to the crane.
3. Dismantle and remove support (90451) from the gas inlet casing (51001).
4. Push gas inlet casing over the guide studs up to the gas outlet casing (61001).
5. Coat two opposite screws (61009) with high-temperature grease and screw in.
6. Remove the guide studs (90317).
7. Coat remaining screws (61009) with high-temperature grease and fit. Fit the screws by
tightening them crosswise, first to the pre-tightening torque, then to the tightening
torque.
8. Remove the lifting gear.
9. Connect the flanges of the gas inlet casing and the bellows.
10. Fit the insulation segments (51215).
© Copyright 2020 ABB. All rights reserved.
Size
Tightening torque [Nm]
M24
M27
M30
HZTL4034_EN
1)
80
/ 480
1)
100
/ 700
1)
100
/ 920
Rev.P