396-3815Y1
Maximum Pump Flow and Application Rates
Number of
Diaphragms
PR17
3
PR30
3
PR40
4
D250
6
396-3815Y1 SureFire PumpRight for Raven RCM
PumpRight
Fertilizer System for
Raven Rate Control
Module (RCM)
Max Flow
Max GPA on 40'
GPM
at 6 MPH
17
35
30
62
40
82
55
Operator should read this
manual before operating the
system.
Max GPA on 60'
at 6 MPH
23.5
41
55
75
Revised 12/04/2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PumpRight PR17 and is the answer not in the manual?

Questions and answers

Summary of Contents for Surefire PumpRight PR17

  • Page 1 Maximum Pump Flow and Application Rates Number of Max Flow Max GPA on 40’ Max GPA on 60’ Diaphragms at 6 MPH at 6 MPH PR17 23.5 PR30 PR40 D250 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 3: Table Of Contents

    Diaphragm Pump Assemblies and Parts Information ........62-91 & Parts • PWM Valve and Motor Parts ................92 QuickStart Setup Sheet See the sheet for your harness, profile, and product setup ©2010-2019 SureFire Ag Systems—All Rights Reserved 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 4 CAUTION: Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTICE is used to address safety practices not related to personal safety. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 5 All electrical harnessing should be checked regularly and should be routed and secured so it will not be pinched, cut, or stretched. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 6 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 7: Introduction

    7. Attach harnesses as shown in Section D. 8. Set up RCM for SureFire fertilizer system as shown in Section F or in the setup instructions sent with the RCM adapter harness. 9. Fill system with water, conduct initial operation and tests per Section F or in the QuickStart instructions.
  • Page 8 System Overview Example The following gives an example of a complete SureFire Fertilizer system with these Introduction components: • In-cab Display • Raven RCM • PumpRight PR17 • Section Valves • Flow Indicators SureFire adapter harness for 1 • Check Valves with Colored Disc Orifices...
  • Page 9 System Overview Example The following gives an example of a complete SureFire Fertilizer system with Li- Introduction quiShift and these components: • In-cab Display • Raven RCM • PumpRight PR17 • LiquiShift Valve Stack 14-pin extension har- • Isolated Feed Flow Indicators...
  • Page 10: Components Liquid

    Second, electromagnetic flowmeters detect the flow by electrically measuring the velocity of the liquid, which makes them independent of viscosity or density of the fluid measured. They are extremely accurate using the standard calibration number. SureFire still recommends you perform a catch test to verify the system is properly installed and configured.
  • Page 11 1-1/4” 1-1/2” 1.3—26 GPM 2000 1” 1” Earlier model flowmeters (meters with white labels with black text) have different calibration numbers. See the documentation for those meters to find the calibration numbers. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 12 Sections 1-6 (product 1) or Sections 7-12 (product Pin B—Black, Ground - 384-1100 Pin C—White, Signal 2). Your system may vary so check the specific 12V=on ; 0V=off instructions with our RCM adapter harness. Mounting Bracket 400-2493Y1 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 13 Then also order the kit above that includes the 2” Manifold x 1/4” MPT fitting. 3/4” Hose Pressure Tap 520-00-055800 1” Hose Pressure Tap 520-00-055850 1 1/2” Hose Pressure Tap 520-00-055900 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 14 Attach 1/4” tubing to 1/4” QC on the side of 1” x 2” tee on outlet side of 90 deg HB sweep gauge port pump 1/4” air bleed valve 1/4” Tubing 1/4” air bleed valve 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 15: Recirculation & Agitation

    Recirculation hose attaches to back of 2” x 1” tee 102-23520-3/4 on pump inlet Start with a quarter to a half turn. 1/2” recirculation hose 1/2” recirculation Recirculation Regulation hose Valve, 102-23520-3/4 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 16 These indicators use an o-ring and wire clip connection to snap together in any configuration necessary. SureFire has simple tee brackets and U-bolts that will mount these to a variety of bar sizes. Two main types of flow indicators are used. On 30”...
  • Page 17 The low flow column has a smaller internal diameter. This means a heavier ball can be used to monitor a smaller flow. SureFire uses the low flow columns with 1/4” push to connect out- let fittings. The flow capability of 1/4” tubing and the low flow column are a 400-2011A1 great pair for rates on 30”...
  • Page 18 PN 136-04-04QC04QC 4 lb check valves are typically used with electric pump systems. SureFire recommends this valve for use with 1/4” tubing applying up to 10 GPA on 30” rows. The recommended minimum system operating pressure for this check is 10 psi, to ensure all checks open fully.
  • Page 19 33.54 (110) 1.372 67.90 60.35 54.32 49.38 45.27 41.78 38.80 1/4 Turn Cap is Outlet FLOW 1.531 75.78 67.36 60.63 55.12 50.52 46.64 43.30 1.681 83.23 73.98 66.58 60.53 55.49 51.22 47.56 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 20 1.239 1.239 All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 21 3.363 3.363 All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 22 3.363 3.363 All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. All application rates (gallons/acres) are estimates based on 0-28-0 (10.65 lbs/gallon) at 70 degrees F. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 23 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 24 Metering Tube / LiquiShiftTube Charts. SureFire dual metering tube plumbing kits are a great way to apply fertilizer. These plumbing kits will contain everything you need to distribute fertilizer from the flowmeter outlet down to the ground application device of your choice (not included).
  • Page 25 T fitting screwed into dual check valve on outside sections. Section 2 Section 1 Section 3 For a 2 section plumbing system, omit the center section and plumb similar to the outside 2 sections. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 26 4x6 inch in the bracket Short tube. notch to length Bracket mount can be cut off. check valve closer to the bar. Long Bracket 311-0408000800-05 1/4” L Bolt 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 27 113-19-025025025 Y Divider - 1/4” QC 1/4” Tubing—Included in Keeton or Rebounder. Can use 1/4” black tubing from SureFire kit. Any length allowed. Connection to Totally Tubular or other heavy wall Stainless Steel Tube Ground Application Devices When using a 3/8” OD stainless steel tube to apply fertilizer to the ground, there are two options for the delivery tube plumbing.
  • Page 28: Wiring & Elec

    SureFire Harness Layout for RAVEN RCM SureFire recommends buying a Raven RCM Adapter Harness from SureFire that Wiring & Elec. will connect directly to the three connectors on the Raven RCM Controller. In-Cab Display (user-provided) Footswitch & ISO Extensions (Purchase from SureFire)
  • Page 29 When using this harness, change fuses on RCM Main Adapter Harness from 15 Amps to 7.5 Amps (QTY 2) and from 25 1. Plug the 35-pin and 23-pin connectors from the SureFire adapter harness (213-00-3467Y_) into the RCM. Amps to 15 Amps (QTY 1).
  • Page 30 Example PumpRight & RCM Layout The harnessing shown below would be used to connect a SureFire PumpRight system with up to 6 section valves to the Raven RCM. Wiring & Elec. Using SureFire Direct to RCM ECU Raven RCM 396-3815Y1 SureFire PumpRight for Raven RCM...
  • Page 31 Wiring 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 32 207-3462Y2 Final Cable for SureFire Liquid Pump System (pwm, flow, pres., pump rpm, fill flow) Wire 18AWG unless otherwise specified Pressure 150 MP Shroud 3-pin Signal +12V Include Dust CAP Pump DEUTSCH 12-pin DT04-12P +12V DC Flowmeter Flow Signal AMP SUPER SEAL TOWER 3-PIN...
  • Page 33 Final Cable for Tower With 1-2 Section Valves (pwm, flow, Last Edit Description: 4/3/2019 Revision A-03 pres., sec 1, sec 2, fill flow) Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 34 Brandon Cavenee Last Edit Description: 14-Pin 6-Section Final Cable (6 sections, flow return, pressure) 11/2/2016 Revision A-01 Date: Copyright 2016 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 35 Flow Signal Pressure Aux. RPM, Motor,  PWM (+) Spinner, Fan PWM (‐) WP TOWER 3‐PIN Fill Flow +12V Pump RPM Signal ORG/WHT Bin Level Open Section 1 Section 2 150 MP Tower 2‐PIN PWM + PWM ‐ Bin Level Sensor 150 MP TOWER   3‐PIN ORG/WHT Signal +12 v Part No: 207‐3492Y2 Drawn By: Brandon Cavenee, Y2‐MAW 12‐pin Final Cable for Basic Dry Fertilizer System (pwm, meter  Last Edit  Description: 2/10/2017 Revision A‐02 rpm, aux rpm, bin level) Date: Copyright 2016 SureFire Ag Systems,  Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 36 213-00-3417Y4 Drawn By: Mark Wolters Last Edit Description: ECU to Liquid Single Product_6 sections 9/4/2018 Revision A-06 Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 37 213-00-3417Y4 Drawn By: Mark Wolters Last Edit Description: ECU to Liquid Single Product_6 sections 9/4/2018 Revision A-06 Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 38 Last Edit Description: ECU Direct to Liquid 2 product and 12 sections adapter harness 9/4/2018 Revision A-06 Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 39 Last Edit Description: ECU Direct to Liquid 2 product and 12 sections adapter harness 9/4/2018 Revision A-06 Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 40 Last Edit Description: ECU Direct to Liquid 2 product and 12 sections adapter harness 9/4/2018 Revision A-06 Date: Copyright 2018 SureFire Ag Systems, Reproduction or other use of drawing Project: without express written permission from SureFire Ag Systems is forbidden...
  • Page 41: Installation Overview

    Dual Product Add-on Kit cap is always check valve Product 2 on bottom Fertilizer Opener, 515-1005 12 Row outlet. Colored disc orifice Seed Firmer, SS 515-1006 6 Row can be placed under cap. Tube, etc. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 42: Installation Overview

    3. SureFire has U-Bolts available to mount the pump directly to multiple bar sizes shown below. If the U- Bolts will not work, order the universal backer plate, number 400-1973A1 which allows use of 1/2” bolts to clamp to any size tube up to 8”...
  • Page 43 If the load sense is needed, do this: First, remove the load sense plug and install a #6 male boss x #6 JIC adapter fitting, SureFire PN 161-01-6MB-6MJ. Then run a 3/8” or 1/4”...
  • Page 44 PumpRight after the seed distribution fan in series. If using this method, the SureFire PWM bypass valve must be open (see previous page for instruction & picture). If bypass is left closed, the SureFire valve will limit the speed of the seed distribution fan.
  • Page 45 PumpRight Hydraulic Oil Flow Requirements (Requirements for 4.0 CID Motor—standard SureFire motor beginning in 2016— Earlier motor was 4.9 CID which uses 20% more oil) Installation Overview Setting Tractor Hydraulic Remote Speed PumpRight pumps require a constant hydraulic oil flow from Model PR17 - 3 Diaphragms the tractor.
  • Page 46 (290 PSI ). Be sure the 100 PSI Pressure Relief Valve (PRV) is installed and functioning so system pressure will be kept under 100 PSI. Check hoses, hose clamps, and liquid fittings regularly and repair or replace loose connections. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 47 (290 PSI). Be sure the 100 PSI Pressure Relief Valve (PRV) is installed and functioning so system pressure will be kept under 100 PSI. Check hoses, hose clamps, and liquid fittings regularly and repair or replace loose connections. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 48: Setup & Operation

    The operator is responsible for knowing and understanding the • Alarm Settings safe operation of this equipment. Systems with hydraulic • Rates Setup/ Display Smoothing / equipment require additional safety precautions to prevent serious Decimal Shift injury and/or death. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 49 Product 2, you must set up 2 sensors, even if you are not using a sensor on Product 1. See the Raven RCM Operation Manual for safety information and additional setup/operating information. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 50 See note above on YES or NO Typical setup shown. Many different section setup combinations are possible. The SureFire harness has Sections 1-6 on one connector and Sections 7-12 on another connector. You could set up each product with 12 sections and share section drivers.
  • Page 51 Setup instructions for Raven RCM and SureFire: 2 Liquid Products 10. Control Valve Setup (start with the numbers indicated for your system) Setup & Operation If pump is slow responding to rate Valve Response Rate: (Adjust as needed) or speed changes, increase Valve PumpRight (hydraulic) Response Rate.
  • Page 52 15. Pressure Sensors must be calibrated. See the boxes below for the procedure. Enter 50.0 mv/ Setup & PSI for SureFire 0 to 5 volt, 0-100 PSI sensor. If you have 2 sensors, both must be calibrated. Be Operation sure there is no pressure against the sensor when calibrating. Unplug the sensor during the calibra- tion process.
  • Page 53 Setup instructions for Raven RCM and SureFire: 2 Liquid Products Implement Height Indicator Setup Setup & Operation Setup Applicator Setup Check the Height Switch box if you are using a Mercury Switch or Finger Style Switch for Implement Height Indication.
  • Page 54 If flow or pressure is not immediately detected, the Solution Pump Dry warning will come up and the system will shut down. Solution Pump Dry is NOT a problem for SureFire electric pumps or for SureFire PumpRight hydraulic diaphragm pumps. It is a problem for centrifugal pumps.
  • Page 55 When testing with water, the system pressure will be much less than it will be with a fertilizer product. Read the Raven RCM Operator’s Manual for safety information and additional setup/operating information. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 56: Troubleshooting Tips

    As-Applied Mapping. Task Controller is typically purchased from the display manufacturer as an Unlock. See the Task Controller documentation from your display manufacturer for more information on setup and operation. For more information, see the SureFire Manual for your Raven RCM system at www.surefireag.com/ support. Read the Raven RCM Operator’s Manual...
  • Page 57: Trouble-Shooting

    Hydraulic Pump Will Not Turn Turn hydraulics off, go to the SureFire PWM valve and use the manual override (red knob) on top of the electric coil to manually open the valve (Manual Override UP = valve fully open). There may be dirt in here that needs to be cleaned out before you can turn and raise the override.
  • Page 58 It is good to know what these values are in normal field operation. They provide good troubleshooting information if there is a problem. 2. These items can be placed on the Run Screen with Display Settings. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 59 5. Change Flow Cal back to appropriate Flow Cal when finished with Tap Test. 6. SureFire has a Speed/Flow Simulator (PN 219-01462) or a Tap Tester (212-03-3912Y1) that can be used to confirm if the wiring is good between the flowmeter and controller.
  • Page 60 Connect the (-) end of the battery to pin C and the (+) end to pin A of the pressure connector. The 1.5 v should show up as 30 psi on the screen. You can check this at Diagnostics > System Information > Pressure Sensors. (0 PSI should be 0.0v) 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 61 It is made to protect centrifugal pumps that can be harmed quickly if they are dry. This is not a problem for SureFire diaphragm pumps. To get to Target Rate quicker on startup, set the PWM Startup % so the pump starts at or near where it will be running.
  • Page 62 The plumbing components of a SureFire system are rated at 100 PSI or above. On an electric pump system, the pump capacity decreases as the pressure increases. Our standard Tower pump has an internal 70 PSI bypass. With an electric pump, we like to see pressures from 10 to 30 PSI.
  • Page 63: Maintenance & Parts

    & Parts Winterization SureFire recommends flushing your fertilizer pump and complete system with adequate amounts of water first. Next, use RV antifreeze to winterize your system by pumping an adequate amount through all components. At the beginning of the next season, begin with water to verify the system is in working order with no leaks.
  • Page 64: Pre-Season Service

    Be sure the 100 PSI Pressure Relief Valve (PRV) is installed and functioning so system pressure will be kept under 100 PSI. Check hoses, hose clamps, and liquid fittings regularly and repair or replace loose connections. 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 65 Other Service Parts D70, D115, D160, D250 D160 - D250 Valves (not shown) are Part Number arranged on (all begin 291-02- Description opposite sides of 9910-xxxxxx) head. 550080 Diaphragm (Buna, Optional) 550190 Accumulator Diaphragm 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 66 BlueFlex Diaphragm 2429051 Valve 3460380 Gasket/O-ring D250 Pump Service Kit - 6 Diaphragm KIT #: 291-13-100200 550081 BlueFlex Diaphragm 759051 Valve 680070 Gasket/O-ring For other service parts, see individual Pump Part Breakout Diagrams 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 67 See Note Below Pump Head Wobble Plate/Diaphragm BlueFlex Sleeve Keeper Washer Diaphragm Inlet Valve NOTE: A multipurpose grease is fine to use for applying in between the Diaphragm and Wobble Plate/Washer Gasket/O-ring 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 68 EMag PR17/PR30 Flowmeter Kit (.6 - 13 GPM) - 1" HB 521-00-100250 Pump Priming and Air Bleed Assembly 161-01-8MB-8MJ Adapter - #8 male O-Ring Boss to #8 male JIC 161-02-8MJ-8FJX-90 Elbow - #8 female JIC to #8 male JIC - 90 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 69 PR17 Poly BlueFlex Diaphragm Pump - 17 GPM - 290-02-PR17 See Page 66 290 PSI 291-02-AR55375 Flange Adapter Kit - PR17 280-150-ENF-25L 1-1/2" Enforcer Hose - PR17 280-100-AG200-25L 1" AG200 Hose - PR17 - 25 inches 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 70 1" EPDM Manifold Gasket 105-150G 1 1/2" EPDM Gasket 105-100BRBSWP90 1" Flange X 90° Sweep Hose Barb 105-100BRBSWPG90 1" Manifold x 1" Hose Barb - 1/4" Gauge Port - 90 Degree Sweep 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 71 3/4" MPT x 1" HB 204-01-46211CUF00 Electro Magnetic Flow meter 0.13-2.6 GPM 204-01-46211CUF01 Electro Magnetic Flow meter 0.3-5 GPM 204-01-46211CUF02 Electro Magnetic Flow meter 0.6-13 GPM 280-100-AG200-8L 1" AG200 Hose 350-1608 1" Hose Clamp 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 72 PR17 Assembly and Part Breakdowns PR17 Polypropylene BlueFlex Diapragm Pump—17 GPM Maintenance P/N: 290-02-PR17 (SP) & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 73 PR17 Assembly and Part Breakdowns PR17 Polypropylene BlueFlex Diaphragm Pump—17 GPM Maintenance P/N: 290-02-PR17 (SP) & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 74 Adapter - #8 male O-Ring Boss to #8 male JIC 161-02-8MJ-8FJX-90 Elbow - #8 female JIC to #8 male JIC - 90 300-080200-5 1/2" x 2" G5 321-08 1/2" Nylock Nut 521-00-100250 Pump Priming and Air Bleed Assembly 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 75 350-TC181 1 1/2" Enforcer or AG200) 350-1608 1" Hose Clamp 280-100-AG200-25L-PR30 1" AG200 Hose - 25 inches 280-150-ENF-25L-PR30 1-1/2" Enforcer Hose - AR 140 280-05-AG200-25L 1/2" AG200 - PR17/30 - 25" L 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 76 1" EPDM Manifold Gasket 105-150G 1 1/2" EPDM Gasket 105-100BRBSWP90 1" Flange X 90° Sweep Hose Barb 105-100BRBSWPG90 1" Manifold x 1" Hose Barb - 1/4" Gauge Port - 90 Degree Sweep 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 77 Electro Magnetic Flow meter .6 - 13 GPM Non-visual 204-01-46211CUF03 Electro Magnetic Flow meter 1.3 - 26 GPM Non-visual 105-100MPT 1" Flange X 1" Male Thread 101-100100 1" MPT x 1" HB 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 78 PR30 Diaphragm Pump Parts PR30 Polypropylene BlueFlex Diapragm Pump—30 GPM Maintenance & Parts P/N: 290-02-PR30 (SP) 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 79 PR30 Diaphragm Pump Parts PR30 Polypropylene BlueFlex Diapragm Pump—30 GPM Maintenance P/N: 290-02-PR30 (SP) & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 80 Adapter - #8 male O-Ring Boss to #8 male JIC 161-02-8MJ-8FJX-90 Elbow - #8 female JIC to #8 male JIC - 90 521-00-100250 Pump Priming and Air Bleed Assembly 300-080200-5 1/2" x 2" G5 321-08-SS 1/2" Nylock Nut-SS 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 81 T-Bolt Hose Clamp - 2.31 - 2.62" Diameter (fits 2" 350-TC231 Enforcer) 350-0605 SS Hose Clamp - Size 6 - 7/8" Diameter 291-02-9910-HYD1570 Hydraulic Flange Kit - D160, D250, PR40 & AR330 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 82 QC to MPT - 1/4" QC x 3/8" MPT 113-05-025 Plug - 1/4" QC 105-100G 1" EPDM Manifold Gasket 105-150G 1 1/2" EPDM Gasket 105-FC100 1" Manifold Clamp 105-FC200 2" Manifold Clamp 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 83 T-Bolt Hose Clamp - 1.81 - 2.06" Diameter 300-050100-SS 5/16" x 1" HCS SS 323-05-SS 5/16" Flange Nut SS 280-150-AG200 1 1/2" AG200 Hose - 2 feet 201-17842 Adapter Cable - AMP Superseal to MT Controller 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 84 PR40 Diaphragm Pump Parts PR40 Polypropylene BlueFlex Diapragm Pump—40 GPM Maintenance & Parts P/N: 290-02-PR40 (C/C) 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 85 PR40 Diaphragm Pump Parts PR40 Polypropylene BlueFlex Diapragm Pump—40 GPM Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 86 161-02-8MJ-8FJX-90 Elbow - #8 female JIC to #8 male JIC - 90 Arag Ion Flowmeter Kit (2.6 - 53 GPM) with adapter See Page 83 500-02-2080 cable - 1 1/2" HB 280-150-AG200 1 1/2" AG200 Hose 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 87 350-0605 SS Hose Clamp - Size 6 - 7/8" Diameter D250-6 Chamber Diaphragm Pump 55 GPM-Pump 290-02-9910-D250 See Page 84 Only 291-02-9910-HYD1570 Hydraulic Flange Kit - D160, D250, PR40 & AR330 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 88 QC to MPT - 1/4" QC x 3/8" MPT 113-05-025 Plug - 1/4" QC 105-100G 1" EPDM Manifold Gasket 105-150G 1 1/2" EPDM Gasket 105-FC100 1" Manifold Clamp 105-FC200 2" Manifold Clamp 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 89 T-Bolt Hose Clamp - 1.81 - 2.06" Diameter 300-050100-SS 5/16" x 1" HCS SS 323-05-SS 5/16" Flange Nut SS 280-150-AG200 1 1/2" AG200 Hose - 2 feet 201-17842 Adapter Cable - AMP Superseal to MT Controller 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 90 D250 Diaphragm Pump Parts D250 BlueFlex Diaphragm Pump—55 GPM Maintenance P/N: 290-02-9910-D250 & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 91 D250 Diaphragm Pump Parts D250 BlueFlex Diapragm Pump—55 GPM Maintenance P/N: 290-02-9910-D250 & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 92 D70 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 93 D115 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 94 D160 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 95 D160 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 96 D250 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 97 D250 Diaphragm Pump Parts Maintenance & Parts 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...
  • Page 98: Pwm Valve And Motor Parts

    (12 Buna 70 Duro O-ring) Male O-Ring #8 Male O- Female JIC Boss x #8 Ring Boss Inlet x #8 Male Male JIC x #8 Male JIC JIC - 90 Outlet (optional) ©2010-2019 SureFire Ag Systems 396-3815Y1 SureFire PumpRight for Raven RCM Revised 12/04/2019...

This manual is also suitable for:

Pumpright pr30Pumpright pr40Pumpright d250

Table of Contents