Operation Manual / A170-M.. - A175-M..
9 Disassembly and assembly / 9.8 Installing the nozzle ring
9.8
Installing the nozzle ring
Fig. 50: Installing nozzle ring 1
1. Secure retaining plate (90338) with screws (90339) and hook in guide rod (90336).
2. Using lifting gear, position nozzle ring (56001) on guide rod (90336). Do not take strain
off lifting gear yet.
3. Fit guide plate (90328) with nuts (61037).
4. Remove the lifting gear.
5. Position nozzle ring (56001) in gas outlet casing.